Diagnosis and morbidity of placenta accreta
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Objective: To examine the diagnostic precision of ultrasound examination for placenta accreta in women with placenta previa and to compare the morbidity associated with accreta to that of previa alone. Methods: This was a retrospective cohort study of all women with previa with/without accreta examined at the University of California, San Francisco (UCSF) between 2002 and 2008. The sensitivity, specificity, negative predictive value (NPV) and positive predictive value (PPV) of ultrasound examination for the diagnosis of accreta were calculated and compared with results from similar studies in the literature. Univariable analysis was used to compare clinical outcomes. Results: The PPV of an ultrasound diagnosis of accreta was 68% and NPV was 98%. Ultrasound had a sensitivity of 89.5%. Compared with previa alone, accreta had an odds ratio (OR) of 89.6 (95% CI, 19.44–412.95) for estimated blood loss > 2 L, an OR of 29.6 (95% CI, 8.20–107.00) for transfusion and an OR of 8.52 (95% CI, 2.58–28.11) for length of hospital stay > 4 days. Conclusion: Placenta accreta is associated with greater morbidity than is placenta previa alone. Ultrasound examination is a good diagnostic test for accreta in women with placenta previa. This is consistent with most other studies in the literature. Copyright © 2011 ISUOG. Published by John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Maternal Morbidity Associated With Multiple Repeat Cesarean Deliveries
Silver, R. M., Landon, M. B., Rouse, D. J., Leveno, K. J., Spong, C. Y., Thom, E. A., Moawad, A. H., Caritis, S. N., Harper, M., Wapner, R. J., et al. (2006) · Obstetrics & Gynecology · doi:10.1097/01.aog.0000219750.79480.84 · Cited by 1,909
Abnormal placentation: Twenty-year analysis
Wu, S., Kocherginsky, M., & Hibbard, J. U. (2005) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2004.12.074 · Cited by 1,331
Optimal management strategies for placenta accreta
Eller, A., Porter, T., Soisson, P., & Silver, R. (2009) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.2008.02037.x · Cited by 578
Maternal Outcome After Conservative Treatment of Placenta Accreta
Sentilhes, L., Ambroselli, C., Kayem, G., Provansal, M., Fernandez, H., Perrotin, F., Winer, N., Pierre, F., Benachi, A., Dreyfus, M., et al. (2010) · Obstetrics & Gynecology · doi:10.1097/aog.0b013e3181d066d4 · Cited by 515
Previous Cesarean Delivery and Risks of Placenta Previa and Placental Abruption
Getahun, D., Oyelese, Y., Salihu, H. M., & Ananth, C. V. (2006) · Obstetrics & Gynecology · doi:10.1097/01.aog.0000206182.63788.80 · Cited by 449
Prenatal diagnosis of placenta previa accreta by transabdominal color Doppler ultrasound
Chou, M. M., Ho, E. S. C., & Lee, Y. H. (2000) · Ultrasound in Obstetrics & Gynecology · doi:10.1046/j.1469-0705.2000.00018.x · Cited by 284
Surgical management of placenta accreta: a cohort series and suggested approach
Angstmann, T., Gard, G., Harrington, T., Ward, E., Thomson, A., & Giles, W. (2010) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2009.08.037 · Cited by 211
Cited by
Obstetric Care Consensus No. 7: Placenta Accreta Spectrum
(2018) · Obstetrics & Gynecology · doi:10.1097/aog.0000000000002983 · Cited by 523
Abnormal Placentation: Placenta Previa, Vasa Previa, and Placenta Accreta
Silver, R. M. (2015) · Obstetrics & Gynecology · doi:10.1097/aog.0000000000001005 · Cited by 519
Cahill, A. G., Beigi, R., Heine, R. P., Silver, R. M., & Wax, J. R. (2018) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2018.09.042 · Cited by 481
D'Antonio, F., Iacovella, C., & Bhide, A. (2013) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.13194 · Cited by 398
Jauniaux, E., Collins, S. L., Jurkovic, D., & Burton, G. J. (2016) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2016.07.044 · Cited by 208
Accuracy of ultrasound for the prediction of placenta accreta
Bowman, Z. S., Eller, A. G., Kennedy, A. M., Richards, D. S., Winter, T. C., Woodward, P. J., & Silver, R. M. (2014) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2014.03.029 · Cited by 151
Real increasing incidence of hysterectomy for placenta accreta following previous caesarean section
Higgins, M. F., Monteith, C., Foley, M., & O’Herlihy, C. (2013) · European Journal of Obstetrics & Gynecology and Reproductive Biology · doi:10.1016/j.ejogrb.2013.08.030 · Cited by 120
“Surgical complications also include urologic injury, infection, fistula formation and massive transfusion [5,11].”
BackgroundMeng, X., Xie, L., & Song, W. (2013) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2013.05.017 · Cited by 118
Romeo, V., Ricciardi, C., Cuocolo, R., Stanzione, A., Verde, F., Sarno, L., Improta, G., Mainenti, P. P., D'Armiento, M., Brunetti, A., et al. (2019) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2019.05.017 · Cited by 113
PAMUS: placenta accreta management across the United States
Esakoff, T. F., Handler, S. J., Granados, J. M., & Caughey, A. B. (2012) · The Journal of Maternal-Fetal & Neonatal Medicine · doi:10.3109/14767058.2011.598585 · Cited by 82
Self-citationHorgan, R., & Abuhamad, A. (2022) · Obstetrics and Gynecology Clinics of North America · doi:10.1016/j.ogc.2022.02.004 · Cited by 59
The MRI features of placental adhesion disorder and their diagnostic significance: systematic review
Rahaim, N. S. A., & Whitby, E. H. (2015) · Clinical Radiology · doi:10.1016/j.crad.2015.04.010 · Cited by 66
Department of Obstetrics and Gynaecology, Q. E. H., Cheng, K. K., & Lee, M. M. (2015) · Hong Kong Medical Journal · doi:10.12809/hkmj154599 · Cited by 57
“The subsequent management plan of MAP was noted and reviewed, and included (1) conservative management (leaving part of or the whole placenta in situ) with or without additional invasive intervention and follow-up, or (2) immediate invasive intervention (including uterine or iliac artery embolisation, balloon tamponad…”
MethodPrenatal sonographic diagnosis of placenta accreta—Impact on maternal and neonatal outcomes
Hall, T., Wax, J. R., Lucas, F. L., Cartin, A., Jones, M., & Pinette, M. G. (2014) · Journal of Clinical Ultrasound · doi:10.1002/jcu.22186 · Cited by 36
Metadata
- Authors
- Esakoff, T. F., Sparks, T. N., Kaimal, A. J., Kim, L. H., Feldstein, V. A., Goldstein, R. B., Cheng, Y. W., & Caughey, A. B.
- Venue
- Ultrasound in Obstetrics & Gynecology
- Publisher
- Wiley
- Published
- 2011-02-08
- Volume
- 37
- Issue
- 3
- Pages
- 324-327
- ISSN
- 0960-7692 (ISSN-L)
- 1469-0705
- OpenAlex
- W2127201417
- Cited by
- 127
- References
- 7
- FWCI
- 5.19
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.