Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 171

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

The reliability of virtual organ computer‐aided analysis (VOCAL) for the semiquantification of ovarian, endometrial and subendometrial perfusion

Open access
Raine‐Fenning, N. J., Campbell, B. K., Clewes, J. S., Kendall, N. R., Johnson, I. R. · 2003 · Ultrasound in Obstetrics & Gynecology

Abstract

Objectives: Three‐dimensional power Doppler angiography (3D‐PDA) has been largely used for the subjective assessment of vascular patterns but semiquantification of the power Doppler signal is now possible. We examined the intraobserver and interobserver reliability of the semiquantification of ovarian, endometrial and subendometrial blood flow using 3D‐PDA, virtual organ computer‐aided analysis (VOCAL™) and shell‐imaging. Methods: 3D‐PDA was used to acquire 20 ovarian and 20 endometrial volumes from 40 different patients at various stages of in vitro fertilization treatment. VOCAL was then used to delineate the 3D areas of interest and the ‘histogram facility’ employed to generate three indices of vascularity: the vascular index, the flow index and the vascularization flow index. Intraobserver and interobserver reliability was assessed by two‐way, mixed, intraclass correlation coefficients (ICCs) and general linear modeling was used to examine for differences in the mean values between each observer. Results: The intraobserver reliability for both observers was extremely high and there were no differences in reliability between the observers for measurements of both volume and vascularity within the ovary or endometrium and its shells. With the exception of the outside subendometrial shell volumes, there were no significant differences between the two observers in the mean values obtained for either endometrial or ovarian volume and vascularity measurements. The interobserver reliability of measurements was equally high throughout with all measurements obtaining a mean ICC of above 0.985. Conclusions: 3D‐PDA and shell‐imaging offer a reliable, practical and non‐invasive method for the assessment of ovarian, endometrial and subendometrial blood flow. Future work should concentrate upon confirming the reliability of data acquisition and the validity of the technique before its predictive value can be truly tested in prospective clinical studies. Copyright © 2003 ISUOG. Published by John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/uog.923

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Raine‐Fenning, N. J., Campbell, B. K., Clewes, J. S., Kendall, N. R., & Johnson, I. R.
Venue
Ultrasound in Obstetrics & Gynecology
Publisher
Wiley
Published
2003-11-10
Volume
22
Issue
6
Pages
633-639
ISSN
  • 0960-7692 (ISSN-L)
  • 1469-0705
OpenAlex
W1965776355
Cited by
171
References
1
FWCI
7.24
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.