The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Analysis of X‐ray spectra by iterative least squares (AXIL): New developments
Abstract
The functionality of the computer package AXIL (Analysis of X‐ray spectra by Iterative Least squares), suitable for the evaluation of energy‐dispersive X‐ray spectra, has been extended in a number of ways. First, a background modelling algorithm, based on the use of mutually orthogonal polynomials was introduced to replace the linear or exponential polynomials employed previously. Second, the Gaussian photopeak model employed in previous versions of the program was extended to include the non‐Gaussian parts of the characteristic peaks and related background contributions. Both innovations are shown to improve the performance of the spectrum evaluation procedure. Third, the user‐friendliness of the evaluation program was enhanced (a) by allowing a PC plug‐in MCA card to be directly controlled from within the program and (b) by extending the command‐interface to allow for repeated execution of series of commands by means of control loops. A brief description of these changes is given; as an application, the accurate evaluation of micro‐XRF images is discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Data Reduction and Error Analysis for the Physical Sciences
Bevington, P. R., Robinson, D. K., Blair, J. M., Mallinckrodt, A. J., & McKay, S. (1993) · Computers in Physics · doi:10.1063/1.4823194 · Cited by 14,824
Ryan, C. G., Clayton, E., Griffin, W. L., Sie, S. H., & Cousens, D. R. (1988) · Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms · doi:10.1016/0168-583x(88)90063-8 · Cited by 510
A computer analysis of X-ray fluorescence spectra
van Espen, P., Nullens, H., & Adams, F. (1977) · Nuclear Instruments and Methods · doi:10.1016/0029-554x(77)90834-5 · Cited by 262
Self-citationClarke, M. D., Weiss, N. A., & Hassett, M. J. (1989) · The Statistician · doi:10.2307/2349026 · Cited by 190
Cited by
A multiplatform code for the analysis of energy-dispersive X-ray fluorescence spectra
Solé, V. A., Papillon, E., Cotte, M., Walter, P., & Susini, J. (2007) · Spectrochimica Acta Part B: Atomic Spectroscopy · doi:10.1016/j.sab.2006.12.002 · Cited by 2,248
Dik, J., Janssens, K., Van Der Snickt, G., van der Loeff, L., Rickers, K., & Cotte, M. (2008) · Analytical Chemistry · doi:10.1021/ac800965g · Cited by 316
Self-citationLombi, E., & Susini, J. (2009) · Plant and Soil · doi:10.1007/s11104-008-9876-x · Cited by 263
Zimnoch, M., Morawski, F., Kuc, T., Samek, L., Bartyzel, J., Gorczyca, Z., Skiba, A., & Rozanski, K. (2020) · Nukleonika · doi:10.2478/nuka-2020-0029 · Cited by 12
Metadata
- Authors
- Vekemans, B., Janssens, K., Vincze, L., Adams, F., & Van Espen, P.
- Venue
- X-Ray Spectrometry
- Publisher
- Wiley
- Published
- 1994-11
- Volume
- 23
- Issue
- 6
- Pages
- 278-285
- ISSN
- 0049-8246 (ISSN-L)
- 1097-4539
- OpenAlex
- W2043339911
- Cited by
- 452
- References
- 4
- FWCI
- 1.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Analysis of X‐ray spectra by iterative least squares (AXIL): New developments. https://app.cochat.ai/papers/10.1002/xrs.1300230609
- The paper
- Vekemans, B., Janssens, K., Vincze, L., Adams, F., & Van Espen, P. (1994). Analysis of X‐ray spectra by iterative least squares (AXIL): New developments. X-Ray Spectrometry. https://doi.org/10.1002/xrs.1300230609
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.