Improving RF Field Homogeneity in Solid-State MAS NMR Using a Loop-Gap Resonator
The DOI matches its Crossref record.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“A single-turn solenoid made from a wide conductive strip, also known as a loop-gap resonator (LGR), will reduce RF losses considerably and is known to provide excellent B 1 homogeneity [26,27].”
From Using low-E resonators to reduce RF heating in biological samples for static solid-state NMR up to 900MHz (2007) · cites this paper as [26]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Gor’kov, P. L., Chekmenev, E. Y., Li, C., Cotten, M., Buffy, J. J., Traaseth, N. J., Veglia, G., & Brey, W. W. (2007) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2006.11.008 · Cited by 213
Metadata
- Authors
- Larsen, F. H., Daugaard, P., Jakobsen, H. J., & Nielsen, N. C.
- Venue
- Journal of Magnetic Resonance, Series A
- Publisher
- Elsevier BV
- Published
- 1995-08
- Volume
- 115
- Issue
- 2
- Pages
- 283-286
- ISSN
- 1064-1858
- Cited by
- 17
- References
- 0
- Language
- en
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Improving RF Field Homogeneity in Solid-State MAS NMR Using a Loop-Gap Resonator. https://app.cochat.ai/papers/10.1006/jmra.1995.1181
- The paper
- Larsen, F. H., Daugaard, P., Jakobsen, H. J., & Nielsen, N. C. (1995). Improving RF Field Homogeneity in Solid-State MAS NMR Using a Loop-Gap Resonator. Journal of Magnetic Resonance, Series A. https://doi.org/10.1006/jmra.1995.1181
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.