Cited by 38Vibration and Dynamic AnalysisAeroelasticity and Vibration ControlDynamics and Control of Mechanical Systems

The DOI matches its Crossref record.

ACTIVE FLUTTER CONTROL OF A CANTILEVER TUBE CONVEYING FLUID USING PIEZOELECTRIC ACTUATORS

Lin, Y.-H., Chu, C.-L.·1996·Journal of Sound and Vibration

Overview

Integrity signals

Registry

Crossref · 10.1006/jsvi.1996.0470

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The piezoelectric actuator could effectively control the flutter of the cantilever pipe by inputting a moderately actuated control voltage.

    “Using optimal independent modal space control, the piezoelectric actuator could effectively control the flutter of the cantilever pipe by inputting a moderately actuated control voltage.”

Citations

Cited by

Sorted by citations

Metadata

Authors
Lin, Y.-H., & Chu, C.-L.
Affiliations
National Taiwan Ocean University (TW)
Venue
Journal of Sound and Vibration
Publisher
Elsevier BV
Published
1996-09
Volume
196
Issue
1
Pages
97-105
ISSN
0022-460X (ISSN-L)
OpenAlex
W2145343624
Cited by
38
References
0
Citations by year
2026: 2 · 2025: 4 · 2024: 6 · 2023: 2 · 2022: 3 · 2021: 2 · 2020: 1 · 2019: 1 · 2018: 1 · 2014: 1 · 2013: 2 · 2012: 1
FWCI
1.75
Type
journal article
Language
en
Open access
closed
Locations
Journal of Sound and Vibration (publishedVersion)
Topics
  • Physical Sciences › Engineering › Mechanical Engineering › Vibration and Dynamic Analysis
  • Physical Sciences › Engineering › Aerospace Engineering › Aeroelasticity and Vibration Control
  • Physical Sciences › Engineering › Control and Systems Engineering › Dynamics and Control of Mechanical Systems
Keywords
active flutter suppression, flutter suppression, fluid-conveying pipes, piezoelectric actuators, Euler-Bernoulli beam, optimal control, flutter instability, vibration suppression

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review