The DOI matches its Crossref record.
EMPLOYING FLUID FLOW IN A CANTILEVER PIPE FOR VIBRATION CONTROL
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The Coriolis force generated when the fluid is transported at a high speed in a pipe may cause the pipe to lose its stability.
“the Coriolis force generated when the fluid is transported at a high speed in a pipe may cause the pipe to lose its stability [97][98] .”
From Vibration control of fluid-conveying pipes: a state-of-the-art review (2023) · cites this paper as [97]
Citations
Cited by
Sorted by citations
Vibration control of fluid-conveying pipes: a state-of-the-art review
Ding, H., & Ji, J. C. (2023) · Applied Mathematics and Mechanics · doi:10.1007/s10483-023-3023-9 · Cited by 132
“For the fluid-conveying cantilevered pipes, some researchers have explored the active control methods based on piezoelectric([108,112,118]) and electromagnetic actuators, the transient optimal closed-loop control method([113]), the active control methods based on changing the fluid flow velocity([97]) and the fluid pr…”
Background
Metadata
- Authors
- Semercigil, S. E., Turan, Ö. F., & Lu, S.
- Affiliations
- Victoria University (AU)
- ORCID
- Turan, Ö.F.
- Venue
- Journal of Sound and Vibration
- Publisher
- Elsevier BV
- Published
- 1997-08
- Volume
- 205
- Issue
- 1
- Pages
- 103-111
- ISSN
- 0022-460X (ISSN-L)
- OpenAlex
- W2091649199
- Cited by
- 13
- References
- 0
- Citations by year
- 2023: 1 · 2019: 1 · 2017: 1 · 2016: 1 · 2015: 1 · 2014: 1 · 2013: 1
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Sound and Vibration (publishedVersion)
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Vibration and Dynamic Analysis
- Physical Sciences › Engineering › Civil and Structural Engineering › Vibration Control and Rheological Fluids
- Physical Sciences › Engineering › Aerospace Engineering › Aeroelasticity and Vibration Control
- Keywords
- fluid-structure interaction, cantilever pipe, vibration control, fluid flow, active vibration control
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review