Multiparameter Phenotyping of Human PBMCs Using Mass Cytometry
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
The standard for single-cell analysis of phenotype and function in recent decades has been fluorescence flow cytometry. Mass cytometry is a newer technology that uses heavy metal ions, rather than fluorochromes, as labels for probes such as antibodies. The binding of these ion-labeled probes to cells is quantitated by mass spectrometry. This greatly increases the number of phenotypic and functional markers that can be probed simultaneously. Here, we review topics that must be considered when adapting existing flow cytometry panels to mass cytometry analysis. We present a protocol and representative panels for surface phenotyping and intracellular cytokine staining (ICS) assays.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bendall, S. C., Simonds, E. F., Qiu, P., Amir, E.-A. D., Krutzik, P. O., Finck, R., Bruggner, R. V., Melamed, R., Trejo, A., Ornatsky, O. I., et al. (2011) · Science · doi:10.1126/science.1198704 · Cited by 2,279
Bandura, D. R., Baranov, V. I., Ornatsky, O. I., Antonov, A., Kinach, R., Lou, X., Pavlov, S., Vorobiev, S., Dick, J. E., & Tanner, S. D. (2009) · Analytical Chemistry · doi:10.1021/ac901049w · Cited by 1,295
Newell, E. W., Sigal, N., Bendall, S. C., Nolan, G. P., & Davis, M. M. (2012) · Immunity · doi:10.1016/j.immuni.2012.01.002 · Cited by 555
Self-citationMultiplexed mass cytometry profiling of cellular states perturbed by small-molecule regulators
Bodenmiller, B., Zunder, E. R., Finck, R., Chen, T. J., Savig, E. S., Bruggner, R. V., Simonds, E. F., Bendall, S. C., Sachs, K., Krutzik, P. O., et al. (2012) · Nature Biotechnology · doi:10.1038/nbt.2317 · Cited by 546
Cited by
Clonally expanded CD8 T cells patrol the cerebrospinal fluid in Alzheimer’s disease
Gate, D., Saligrama, N., Leventhal, O., Yang, A. C., Unger, M. S., Middeldorp, J., Chen, K., Lehallier, B., Channappa, D., De Los Santos, M. B., et al. (2020) · Nature · doi:10.1038/s41586-019-1895-7 · Cited by 992
Guidelines for the use of flow cytometry and cell sorting in immunological studies (second edition)
Cossarizza, A., Chang, H., Radbruch, A., Acs, A., Adam, D., Adam‐Klages, S., Agace, W. W., Aghaeepour, N., Akdis, M., Allez, M., et al. (2019) · European Journal of Immunology · doi:10.1002/eji.201970107 · Cited by 979
Self-citationMonaco, G., Lee, B., Xu, W., Mustafah, S., Hwang, Y. Y., Carré, C., Burdin, N., Visan, L., Ceccarelli, M., Poidinger, M., et al. (2019) · Cell Reports · doi:10.1016/j.celrep.2019.01.041 · Cited by 958
“More specifically, mass cytometry cannot be used to sort cells, as it disintegrates the cells analyzed, and there are additional contaminating sources that must be considered, such as metal impurities and oxidation products (Leipold et al., 2015).”
BackgroundMcKinnon, K. M. (2018) · Current Protocols in Immunology · doi:10.1002/cpim.40 · Cited by 728
Guidelines for the use of flow cytometry and cell sorting in immunological studies *
Cossarizza, A., Chang, H., Radbruch, A., Akdis, M., Andrä, I., Annunziato, F., Bacher, P., Barnaba, V., Battistini, L., Bauer, W. M., et al. (2017) · European Journal of Immunology · doi:10.1002/eji.201646632 · Cited by 542
Self-citation
Metadata
- Authors
- Leipold, M. D., Newell, E. W., & Maecker, H. T.
- Venue
- Methods in Molecular Biology
- Publisher
- Springer New York
- Published
- 2015
- Volume
- 1343
- Pages
- 81-95
- ISSN
- 1064-3745 (ISSN-L)
- 1940-6029
- OpenAlex
- W2414055539
- Cited by
- 103
- References
- 4
- FWCI
- 13.38
- Type
- book chapter
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Multiparameter Phenotyping of Human PBMCs Using Mass Cytometry. https://app.cochat.ai/papers/10.1007/978-1-4939-2963-4_7
- The paper
- Leipold, M. D., Newell, E. W., & Maecker, H. T. (2015). Multiparameter Phenotyping of Human PBMCs Using Mass Cytometry. Methods in Molecular Biology. https://doi.org/10.1007/978-1-4939-2963-4_7
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.