The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
High-Resolution Respirometry: OXPHOS Protocols for Human Cells and Permeabilized Fibers from Small Biopsies of Human Muscle
Abstract
Protocols for high-resolution respirometry (HRR) of intact cells, permeabilized cells, and permeabilized muscle fibers offer sensitive diagnostic tests of integrated mitochondrial function using standard cell culture techniques and small needle biopsies of muscle. Multiple substrate-uncoupler-inhibitor titration (SUIT) protocols for analysis of oxidative phosphorylation improve our understanding of mitochondrial respiratory control and the pathophysiology of mitochondrial diseases. Respiratory states are defined in functional terms to account for the network of metabolic interactions in complex SUIT protocols with stepwise modulation of coupling and substrate control. A regulated degree of intrinsic uncoupling is a hallmark of oxidative phosphorylation, whereas pathological and toxicological dyscoupling is evaluated as a mitochondrial defect. The noncoupled state of maximum respiration is experimentally induced by titration of established uncouplers (FCCP, DNP) to collapse the proton gradient across the mitochondrial inner membrane and measure the capacity of the electron transfer system (ETS, open-circuit operation of respiration). Intrinsic uncoupling and dyscoupling are evaluated as the flux control ratio between nonphosphorylating LEAK respiration (electron flow coupled to proton pumping to compensate for proton leaks) and ETS capacity. If OXPHOS capacity (maximally ADP-stimulated oxygen flux) is less than ETS capacity, the phosphorylation system contributes to flux control. Physiological Complex I + II substrate combinations are required to reconstitute TCA cycle function. This supports maximum ETS and OXPHOS capacities, due to the additive effect of multiple electron supply pathways converging at the Q-junction. Substrate control with electron entry separately through Complex I (pyruvate + malate or glutamate + malate) or Complex II (succinate + rotenone) restricts ETS capacity and artificially enhances flux control upstream of the Q-cycle, providing diagnostic information on specific branches of the ETS. Oxygen levels are maintained above air saturation in protocols with permeabilized muscle fibers to avoid experimental oxygen limitation of respiration. Standardized two-point calibration of the polarographic oxygen sensor (static sensor calibration), calibration of the sensor response time (dynamic sensor calibration), and evaluation of instrumental background oxygen flux (systemic flux compensation) provide the unique experimental basis for high accuracy of quantitative results and quality control in HRR.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
RESPIRATORY ENZYMES IN OXIDATIVE PHOSPHORYLATION
Chance, B., & Williams, G. R. (1955) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)57189-7 · Cited by 1,473
Patients with type 2 diabetes have normal mitochondrial function in skeletal muscle
Boushel, R., Gnaiger, E., Schjerling, P., Skovbro, M., Kraunsøe, R., & Dela, F. (2007) · Diabetologia · doi:10.1007/s00125-007-0594-3 · Cited by 519
Self-citationGnaiger, E. (2001) · Respiration Physiology · doi:10.1016/s0034-5687(01)00307-3 · Cited by 280
Self-citationHUTTER, E., RENNER, K., PFISTER, G., STÖCKL, P., JANSEN-DÜRR, P., & GNAIGER, E. (2004) · Biochemical Journal · doi:10.1042/bj20040095 · Cited by 235
Self-citationTop-down control analysis of temperature effect on oxidative phosphorylation
DUFOUR, S., ROUSSE, N., CANIONI, P., & DIOLEZ, P. (1996) · Biochemical Journal · doi:10.1042/bj3140743 · Cited by 111
Cited by
Tan, A. S., Baty, J. W., Dong, L.-F., Bezawork-Geleta, A., Endaya, B., Goodwin, J., Bajzikova, M., Kovarova, J., Peterka, M., Yan, B., et al. (2015) · Cell Metabolism · doi:10.1016/j.cmet.2014.12.003 · Cited by 785
Mahul-Mellier, A.-L., Burtscher, J., Maharjan, N., Weerens, L., Croisier, M., Kuttler, F., Leleu, M., Knott, G. W., & Lashuel, H. A. (2020) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1913904117 · Cited by 710
Mitofusin 2 in POMC neurons connects ER stress with leptin resistance and energy imbalance
Schneeberger, M., Dietrich, M. O., Sebastián, D., Imbernón, M., Castaño, C., Garcia, A., Esteban, Y., Gonzalez-Franquesa, A., Rodríguez, I. C., Bortolozzi, A., et al. (2013) · Cell · doi:10.1016/j.cell.2013.09.003 · Cited by 519
Elhassan, Y. S., Kluckova, K., Fletcher, R. S., Schmidt, M. S., Garten, A., Doig, C. L., Cartwright, D. M., Oakey, L., Burley, C. V., Jenkinson, N., et al. (2019) · Cell Reports · doi:10.1016/j.celrep.2019.07.043 · Cited by 448
Coen, P. M., Jubrias, S. A., Distefano, G., Amati, F., Mackey, D. C., Glynn, N. W., Manini, T. M., Wohlgemuth, S. E., Leeuwenburgh, C., Cummings, S. R., et al. (2013) · The Journals of Gerontology: Series A · doi:10.1093/gerona/gls196 · Cited by 323
Metadata
- Authors
- Pesta, D., & Gnaiger, E.
- Venue
- Methods in Molecular Biology
- Publisher
- Humana Press
- Published
- 2011-10-03
- Volume
- 810
- Pages
- 25-58
- ISSN
- 1064-3745 (ISSN-L)
- 1940-6029
- OpenAlex
- W191921287
- Cited by
- 987
- References
- 5
- FWCI
- 36.93
- Type
- book chapter
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High-Resolution Respirometry: OXPHOS Protocols for Human Cells and Permeabilized Fibers from Small Biopsies of Human Muscle. https://app.cochat.ai/papers/10.1007/978-1-61779-382-0_3
- The paper
- Pesta, D., & Gnaiger, E. (2012). High-Resolution Respirometry: OXPHOS Protocols for Human Cells and Permeabilized Fibers from Small Biopsies of Human Muscle. Methods in Molecular Biology. https://doi.org/10.1007/978-1-61779-382-0_3
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.