Comprehensive Automation for NMR Structure Determination of Proteins
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
This chapter gives an overview of automated protein structure determination by nuclear magnetic resonance (NMR) with the UNIO protocol that enables high to full automation of all NMR data analysis steps involved. Four established algorithms, namely, the MATCH algorithm for sequence-specific resonance assignment, the ASCAN algorithm for side-chain resonance assignment, the CANDID algorithm for NOE assignment, and the ATNOS algorithm for signal identification in NMR spectra, are assembled into three principal UNIO NMR data analysis components (MATCH, ATNOS/ASCAN, and ATNOS/CANDID) that are accessed thanks to a particularly intuitive and flexible, yet powerful graphical user interface (GUI). UNIO is designed to work independently or in association with other NMR software. The principal data analysis components for sequence-specific backbone, side-chain and NOE assignment may be run separately or out of sequence. User-intervention at individual stages is encouraged and facilitated by graphical tools included for the preparation, analysis, validation, and subsequent presentation of the NMR structure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
NMR View: A computer program for the visualization and analysis of NMR data
Johnson, B. A., & Blevins, R. A. (1994) · Journal of Biomolecular NMR · doi:10.1007/bf00404272 · Cited by 3,090
The Xplor-NIH NMR molecular structure determination package
Schwieters, C. D., Kuszewski, J. J., Tjandra, N., & Marius Clore, G. (2003) · Journal of Magnetic Resonance · doi:10.1016/s1090-7807(02)00014-9 · Cited by 2,369
Using Xplor–NIH for NMR molecular structure determination
SCHWIETERS, C., KUSZEWSKI, J., & MARIUSCLORE, G. (2006) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2005.10.001 · Cited by 769
Cited by
BID-induced structural changes in BAK promote apoptosis
Moldoveanu, T., Grace, C. R., Llambi, F., Nourse, A., Fitzgerald, P., Gehring, K., Kriwacki, R. W., & Green, D. R. (2013) · Nature Structural & Molecular Biology · doi:10.1038/nsmb.2563 · Cited by 204
Proteins behaving badly: emerging technologies in profiling biopharmaceutical aggregation
Hamrang, Z., Rattray, N. J. W., & Pluen, A. (2013) · Trends in Biotechnology · doi:10.1016/j.tibtech.2013.05.004 · Cited by 75
Huang, Y. J., Zhang, N., Bersch, B., Fidelis, K., Inouye, M., Ishida, Y., Kryshtafovych, A., Kobayashi, N., Kuroda, Y., Liu, G., et al. (2021) · Proteins: Structure, Function, and Bioinformatics · doi:10.1002/prot.26246 · Cited by 49
Bersch, B., Bougault, C., Roux, L., Favier, A., Vernet, T., & Durmort, C. (2013) · PLoS ONE · doi:10.1371/journal.pone.0081168 · Cited by 49
“The UNIO’10 software [55] was used for automatic peak”
Method
Metadata
- Authors
- Guerry, P., & Herrmann, T.
- Venue
- Methods in Molecular Biology
- Publisher
- Humana Press
- Published
- 2011-11-18
- Volume
- 831
- Pages
- 429-451
- ISSN
- 1064-3745 (ISSN-L)
- 1940-6029
- OpenAlex
- W2401285145
- Cited by
- 58
- References
- 3
- FWCI
- 20.17
- Type
- book chapter
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.