The DOI matches its Crossref record.
Biomedical Signal Processing: Innovation and Applications
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Detection of Abrupt Changes: Theory and Application
Riedel, K. S. (1994) · Technometrics · doi:10.1080/00401706.1994.10485821 · Cited by 3,518
The weighted diagnostic distortion (WDD) measure for ECG signal compression
Zigei, Y., Cohen, A., & Katz, A. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2000.880093 · Cited by 405
Evaluation of the forearm EMG signal features for the control of a prosthetic hand
Boostani, R., & Moradi, M. H. (2003) · Physiological Measurement · doi:10.1088/0967-3334/24/2/307 · Cited by 391
Signorini, M. G., Magenes, G., Cerutti, S., & Arduini, D. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.808824 · Cited by 294
Micera, S., Sabatini, A. M., Dario, P., & Rossi, B. (1999) · Medical Engineering & Physics · doi:10.1016/s1350-4533(99)00055-7 · Cited by 90
Pathological assessment of patients’ speech signals using nonlinear dynamical analysis
Vaziri, G., Almasganj, F., & Behroozmand, R. (2010) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2009.10.011 · Cited by 88
Metadata
- Venue
- Springer eBooks
- Publisher
- Springer International Publishing
- Published
- 2021
- OpenAlex
- W640518560
- Cited by
- 261
- References
- 0
- FWCI
- 2.91
- Type
- book
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.