“Are You with Me?” – Using Accelerometers to Determine If Two Devices Are Carried by the Same Person
The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Welch, P. (1967) · IEEE Transactions on Audio and Electroacoustics · doi:10.1109/tau.1967.1161901 · Cited by 12,277 · cited 1×
“As our goal is to use these algorithms in environments with limited computing power we limit ourselves to two windowed segments, no overlapping segments, and a FFT size equal to the size of the input data [11, 14, 15].”
MethodBiomechanics and motor control of human movement
(1990) · Choice Reviews Online · doi:10.5860/choice.28-2135 · Cited by 8,451
Coherence and time delay estimation
Carter, G. C. (1987) · Proceedings of the IEEE · doi:10.1109/proc.1987.13723 · Cited by 1,200 · cited 1×
“Coherence, γxy( ƒ ), is a normalized function of frequency derived from the crossspectrum of two signals, Sxy, divided by the power spectrum of each signal, Sxx and Syy [11, 12].”
BackgroundComposing domain-specific design environments
Ledeczi, A., Bakay, A., Maroti, M., Volgyesi, P., Nordstrom, G., Sprinkle, J., & Karsai, G. (2001) · Computer · doi:10.1109/2.963443 · Cited by 1,130 · cited 1×
“wireless sensor networks is demonstrating that the communicating nodes may become as small as “smart dust”[ 1 ] and function with a high degree of power efficiency.”
BackgroundSmart Dust: communicating with a cubic-millimeter computer
Warneke, B., Last, M., Liebowitz, B., & Pister, K. S. J. (2001) · Computer · doi:10.1109/2.895117 · Cited by 697
Carter, G., Knapp, C., & Nuttall, A. (1973) · IEEE Transactions on Audio and Electroacoustics · doi:10.1109/tau.1973.1162496 · Cited by 514 · cited 1×
“As our goal is to use these algorithms in environments with limited computing power we limit ourselves to two windowed segments, no overlapping segments, and a FFT size equal to the size of the input data [11, 14, 15].”
MethodSpectrum: spectral analysis of unevenly spaced paleoclimatic time series
Schulz, M., & Stattegger, K. (1997) · Computers & Geosciences · doi:10.1016/s0098-3004(97)00087-3 · Cited by 501 · cited 1×
“Coherence measures the extent to which two signals are linearly related at each frequency, with 1 indicating that two signals are highly correlated at a given frequency and 0 indicating that two signals are uncorrelated at that frequency [8, 12, 14 ].”
BackgroundSmart-Its Friends: A Technique for Users to Easily Establish Connections between Smart Artefacts
Holmquist, L. E., Mattern, F., Schiele, B., Alahuhta, P., Beigl5, M., & Gellersen, H.-W. (2001) · Lecture Notes in Computer Science · doi:10.1007/3-540-45427-6_10 · Cited by 498 · cited 2×
“Three different 3-axis MEMS accelerometers were used for our experiments, two were low cost commercial accelerometers from Analog Devices [4, 5] and STMicroelectronics, and the third was a calibrated accelerometer from Crossbow Technologies.”
BackgroundMethodSynchronous gestures for multiple persons and computers
Hinckley, K. (2003) · Proceedings of the 16th annual ACM symposium on User interface software and technology · doi:10.1145/964696.964713 · Cited by 260 · cited 1×
“Hinckley has developed a similar technique that uses bumping rather than shaking [6].”
MethodXWand: UI for intelligent spaces
Wilson, A., & Shafer, S. (2003) · Proceedings of the SIGCHI Conference on Human Factors in Computing Systems · doi:10.1145/642611.642706 · Cited by 230 · cited 1×
“Gesture recognition using accelerometers has been used to develop a wand to remote control devices in a smart space [3] and a glove that uses sensing on all the fingers to create an “air keyboard” for text input [4].”
MethodCarter, G. C. (1993) · Virtual Defense Library (Ministerio de Defensa) · Cited by 182
Acceleration sensing glove (ASG)
Perng, J. K., Fisher, B., Hollar, S. E.-A., & Pister, K. S. J. (2003) · International Symposium on Wearable Computers · doi:10.1109/iswc.1999.806717 · Cited by 153
WearNET: A Distributed Multi-sensor System for Context Aware Wearables
Lukowicz, P., Junker, H., Stäger, M., von Büren, T., & Tröster, G. (2002) · Lecture notes in computer science · doi:10.1007/3-540-45809-3_28 · Cited by 112 · cited 2×
“Example of filtered magnitude data from accelerometer, similar to [10].”
MethodPhysical activity recognition from acceleration data under semi-naturalistic conditions
Bao, L. (2003) · DSpace@MIT (Massachusetts Institute of Technology) · Cited by 78
Synchrony of rest tremor in multiple limbs in Parkinson's disease: evidence for multiple oscillators
Ben‐Pazi, H., Bergman, H., Goldberg, J. A., Giladi, N., Hansel, D., Reches, A., & Simon, E. S. (2001) · Journal of Neural Transmission · doi:10.1007/s007020170074 · Cited by 76 · cited 4×
“Ben-Pazi et al.[7] used the coherence function to analyze the origin of rest tremors in patients with Parkinson's.”
BackgroundInfluential
Cited by
A framework of energy efficient mobile sensing for automatic user state recognition
Wang, Y., Lin, J., Annavaram, M., Jacobson, Q. A., Hong, J., Krishnamachari, B., & Sadeh, N. (2009) · Proceedings of the 7th international conference on Mobile systems, applications, and services · doi:10.1145/1555816.1555835 · Cited by 434
ACCessory: password inference using accelerometers on smartphones
Owusu, E., Han, J., Das, S., Perrig, A., & Zhang, J. (2012) · Proceedings of the Twelfth Workshop on Mobile Computing Systems & Applications - HotMobile '12 · doi:10.1145/2162081.2162095 · Cited by 370
Shake Well Before Use: Intuitive and Secure Pairing of Mobile Devices
Mayrhofer, R., & Gellersen, H. (2009) · IEEE Transactions on Mobile Computing · doi:10.1109/tmc.2009.51 · Cited by 277
Shake Well Before Use: Authentication Based on Accelerometer Data
Mayrhofer, R., & Gellersen, H. (2007) · Lecture Notes in Computer Science · doi:10.1007/978-3-540-72037-9_9 · Cited by 236
“[13] and describes how to determine if two devices are carried by the same person.”
BackgroundIdentifying people from gait pattern with accelerometers
Ailisto, H. J., Lindholm, M., Mantyjarvi, J., Vildjiounaite, E., & Makela, S.-M. (2005) · SPIE Proceedings · doi:10.1117/12.603331 · Cited by 216
Metadata
- Authors
- Lester, J., Hannaford, B., & Borriello, G.
- Venue
- Lecture Notes in Computer Science
- Publisher
- Springer Berlin Heidelberg
- Published
- 2004
- Pages
- 33-50
- ISSN
- 0302-9743 (ISSN-L)
- 1611-3349
- OpenAlex
- W1644895716
- Cited by
- 189
- References
- 15
- FWCI
- 7.76
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.