The DOI matches its Crossref record; the references it cites are not checked yet.
Is There Any Place for Magnetocardiographic Imaging in the Era of Robotic Ablation of Cardiac Arrhythmias?
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The VitalScan/Corsens features novel compact mini-induction coil magnetometers assembled in a hexagonal 19-sensors array to detect MCG from a measurement surface of about 25 cm × 25 cm.
“it features novel compact mini-induction coil magnetometers assembled in a hexagonal 19-sensors array to detect MCG from a measurement surface of about 25 cm × 25 cm.”
From Clinical magnetocardiography: the unshielded bet—past, present, and future (2023) · cites this paper as [261]
Citations
The citation lists haven’t been fetched yet
References 25 · Cited by 6
Research works printed but not linked: 19
- Blomstrom-Lundqvist, C., Scheinman, MM., Aliot, EM., Alpert, JS., Calkins, H., Camm, AJ., et al.: American College of Cardiology; ACC/AHA/ESC guidelines for the management of patients with supraventricular arrhythmias–executive summary. Circulation 108(15), 1871–1909 (2003) · DOI
- Gepstein, L., Wolf, T., Hayam, G., Ben-Haim, SA.: Accurate linear radiofrequency lesions guided by a Nonfluoroscopic electroanatomical mapping method during atrial fibrillation. Pacing Clin Electrophysiol. 24(24), 1672–1678 (2001) · DOI
- Wittkampf, FH., Wever, EF., Derksen, R., Ramanna, H., Hauer, RN., de Medina, EO.R.: LocaLisa: new technique for real-time 3-dimensional localization of regular intracardiac electrodes. Circulation 99(10), 1312–1317 (1999) · DOI
- Gurevitz, OT., Glikson, M., Asirvatham, S., Kester, TA., Grice, SK., Munger, TM., et al.: Use of advanced mapping systems to guide ablation in complex cases: experience with noncontact mapping and electroanatomic mapping systems. Pacing Clin Electrophysiol. 28(4), 316–323 (2005) · DOI
- Faddis, M.N., Chen, J., Osborn, J., Talcott, M., Cain, M.E., Lindsay, B.D.: Magnetic guidance system for cardiac electrophysiology: a prospective trial of safety and efficacy in humans. J. Am. Coll. Cardiol. 42(11), 1952–1958 (2003) · DOI
- Corrado, D., Basso, C., Leoni, L., Tokajuk, B., Bauce, B., Frigo, G., et al.: Three-dimensional electroanatomic voltage mapping increases accuracy of diagnosing arrhythmogenic right ventricular cardiomyopathy/dysplasia. Circulation 14,111(23), 3042–3050 (2005) · DOI
- Ernst, S., Ouyang, F., Linder, C., Hertting, K., Stahl, F., Chun, J. et al.: Initial experience with remote catheter ablation using a novel magnetic navigation system: magnetic remote catheter ablation. Circulation 109(12), 1472–1475 (2004) · DOI
- Dickfeld, T., Calkins, H., Bradley, D., Solomon, S.: Stereotactic catheter navigation using magnetic resonance image integration in the human heart. Heart Rhythm. 2(4), 413–415 (2005) · DOI
- Fenici, R., Brisinda, D., Meloni, AM., Fenici, P.: First 36-channel System for Clinical Magnetocardiography in Unshielded Hospital Laboratory for Cardiac Electrophysiology. Int. J. of Bioelectromagnetism. 1, 80–83 (2003)
- Fenici, R., Brisinda, D., Nenonen, J., Fenici, P.: Phantom validation of multichannel magnetocardiography source localization. Pacing Clin Electrophysiol. 26(1, Part II), 426–430 (2003) · DOI
- Veisterä, H., Fenici, R., Lötjönen, J.: Online heart model creation for magnetocardiographic measurements. In: Halgren, E., Ahlfors, S., Hämäläinen, M., Cohen, D. (eds.) Proceedings of the 14th International Conference on Biomagnetism: vol. 415 (2004)
- Nenonen, J.: Magnetocardiography. In: Clark, J., Braginski, A. (eds.) SQUID, Handbook, Berlin, Whiley-VCH, Chichester (2005)
- Brisinda, D., Fenici, R.: Non-invasive Classification and Follow-up of WPW patients with unshielded Magnetocardiography and Transesophageal Atrial Pacing. Pacing and Clinical Electrophysiol. 30 [Suppl 1], S151–S155 (2007)
- Fenici, R., Brisinda, D.: Magnetocardiography provides non-invasive three-dimensional electroanatomical imaging of cardiac electrophysiology. Int. J. Cardiovasc Imaging. 22(3-4), 595–597 (2006) · DOI
- Fenici, R., Melillo, G.: Magnetocardiography: ventricular arrhythmias. Eur. Heart J. 14(Suppl E), 53–60 (1993) · DOI
- Yamada, S., Tsukada, K., Miyashita, T., Kuga, K., Yamaguchi, I.: Noninvasive, direct visualization of macro-reentrant circuits by using magnetocardiograms: initiation and persistence of atrial flutter. Europace. 5(4), 343–350 (2003) · DOI
- Nakai, K., Kawazoe, K., Izumoto, H., Tsuboi, J., Oshima, Y., Oka, T. et al.: Construction of a three-dimensional outline of the heart and conduction pathway by means of a 64-channel magnetocardiogram in patients with atrial flutter and fibrillation. Int. J. Cardiovasc Imaging. 21[5], 555–561 (2005) · DOI
- Nakai, K., Izumoto, H., Kawazoe, K., Tsuboi, J., Fukuhiro, Y., Oka, T., et al.: Three-dimensional recovery time dispersion map by 64-channel magnetocardiography may demonstrate the location of a myocardial injury and heterogeneity of repolarization. Int. J. Cardiovasc Imaging 22[3-4], 573–580 (2006) · DOI
- Ogata, K., Kandori, A., Miyashita, T., Tsukada, K., Nakatani, S., Shimizu, W. et al.: Visualization of three-dimensional cardiac electrical excitation using standard heart model and anterior and posterior magnetocardiogram. Int. J. Cardiovasc Imaging. 22(3-4), 581–593 (2006) · DOI
Metadata
- Authors
- Fenici, R., & Brisinda, D.
- Affiliations
- Università Cattolica del Sacro Cuore (IT)
- Venue
- Lecture Notes in Computer Science
- Publisher
- Springer Berlin Heidelberg
- Published
- 2007-07-16
- Pages
- 230-239
- OpenAlex
- W1566032266
- Cited by
- 6
- References
- 25
- Citations by year
- 2025: 1 · 2023: 1 · 2013: 1
- FWCI
- 2.27
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- Springer eBooks (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Arrhythmias and Treatments
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Keywords
- magnetocardiography, cardiac arrhythmias, arrhythmogenic substrate, ablation failure, cardiac electrophysiology
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review