An Image-Guided Surgery System to Aid Endovascular Treatment of Complex Aortic Aneurysms: Description and Initial Clinical Experience
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Patient rotation between CT and fluoroscopy position was 3°-4° on average (max 8°) based on 23 patient studies.
“Penney et al reported that patient rotation between CT and fluoroscopy position was 3°–4° on average (max 8°) based on 23 patient studies (Penney et al 2011).”
From Robust 3D–2D image registration: application to spine interventions and vertebral labeling in the presence of anatomical deformation (2013) · cites this paper as Penney et al 2011
Cited by
Sorted by citations
Otake, Y., Wang, A. S., Webster Stayman, J., Uneri, A., Kleinszig, G., Vogt, S., Khanna, A. J., Gokaslan, Z. L., & Siewerdsen, J. H. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/23/8535 · Cited by 85 · see citing works
Fully automated 2D–3D registration and verification
Varnavas, A., Carrell, T., & Penney, G. (2015) · Medical Image Analysis · doi:10.1016/j.media.2015.08.005 · Cited by 50 · see citing works
Self-citation
- Authors
- Penney, G., Varnavas, A., Dastur, N., & Carrell, T.
- Affiliations
- St Thomas' Hospital (GB)
- Venue
- Lecture Notes in Computer Science
- Publisher
- Springer Berlin Heidelberg
- Published
- 2011
- Pages
- 13-24
- ISSN
- 0302-9743 (ISSN-L)
- 1611-3349
- OpenAlex
- W200789693
- Cited by
- 22
- References
- 0
- Citations by year
- 2021: 2 · 2020: 1 · 2018: 1 · 2017: 1 · 2016: 2 · 2015: 4 · 2014: 1 · 2013: 8 · 2012: 2
- FWCI
- 2.63
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- Lecture notes in computer science (publishedVersion)
- Research Portal (King's College London) (submittedVersion)
- Topics
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Medical Image Segmentation Techniques
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Aortic aneurysm repair treatments
- Physical Sciences › Engineering › Biomedical Engineering › Anatomy and Medical Technology
- Keywords
- image-guided surgery, aortic aneurysm, endovascular aneurysm repair, 2D-3D registration, fluoroscopy, 3D surface rendering, surgical guidance, registration accuracy, non-rigid deformation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review