Prediction of Geochemical Composition from XRF Core Scanner Data: A New Multivariate Approach Including Automatic Selection of Calibration Samples and Quantification of Uncertainties
The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hierarchical Grouping to Optimize an Objective Function
Ward, J. H. (1963) · Journal of the American Statistical Association · doi:10.1080/01621459.1963.10500845 · Cited by 20,598 · cited 1×
“We use Ward’s method (Ward 1963) in conjunction with a Euclidian distance measure to subdivide the clrtransformed scaled intensities into Nc clusters, and select one data point from each cluster (the one closest to the cluster centroid).”
MethodNumerical recipes in Pascal: the art of scientific computing
(1990) · Choice Reviews Online · doi:10.5860/choice.27-5158 · Cited by 11,811
The Statistical Analysis of Compositional Data
Aitchison, J. (1986) · doi:10.1007/978-94-009-4109-0 · Cited by 4,383
The Statistical Analysis of Compositional Data
Piepel, G. F. (1988) · Technometrics · doi:10.1080/00401706.1988.10488337 · Cited by 3,418
The Statistical Analysis of Compositional Data
Aitchison, J. (1982) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1982.tb01195.x · Cited by 3,405
The Predictive Sample Reuse Method with Applications
Geisser, S. (1975) · Journal of the American Statistical Association · doi:10.1080/01621459.1975.10479865 · Cited by 2,748 · cited 1×
“Because our data are not noise-free and we should allow for the possibility that the model may not be fully correct, we use a more objective and robust measure of model performance than the regression error: leaving-out-one cross validation (Geisser 1975).”
MethodSIMPLS: An alternative approach to partial least squares regression
de Jong, S. (1993) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/0169-7439(93)85002-x · Cited by 1,905
Handbook of X-Ray Spectrometry
(2001) · CRC Press eBooks · doi:10.1201/9780203908709 · Cited by 1,124
ITRAX: description and evaluation of a new multi-function X-ray core scanner
Croudace, I. W., Rindby, A., & Rothwell, R. G. (2006) · Geological Society, London, Special Publications · doi:10.1144/gsl.sp.2006.267.01.04 · Cited by 880
Self-citationWeltje, G. J., & Tjallingii, R. (2008) · Earth and Planetary Science Letters · doi:10.1016/j.epsl.2008.07.054 · Cited by 787 · cited 9×
“The conceptual problems of DLC are apparent from the fact that the seemingly straightforward (linear) calibration of intensities to concentrations is inconsistent with the parametric model used in XRF spectrometry (Weltje and Tjallingii 2008).”
BackgroundMethodInfluentialSelf-citationNumerical Recipes in Fortran: The Art of Scientific Computing.
G., W., Press, W. H., Teukolsky, S. A., Vetterling, W. T., & Flannery, B. P. (1994) · Mathematics of Computation · doi:10.2307/2153422 · Cited by 751
Calvert, S. E., & Pedersen, T. F. (2007) · Developments in Marine Geology · doi:10.1016/s1572-5480(07)01019-6 · Cited by 552
The Avaatech XRF Core Scanner: technical description and applications to NE Atlantic sediments
Richter, T. O., van der Gaast, S., Koster, B., Vaars, A., Gieles, R., de Stigter, H. C., De Haas, H., & van Weering, T. C. E. (2006) · Geological Society, London, Special Publications · doi:10.1144/gsl.sp.2006.267.01.03 · Cited by 482
Tjallingii, R., Röhl, U., Kölling, M., & Bickert, T. (2007) · Geochemistry, Geophysics, Geosystems · doi:10.1029/2006gc001393 · Cited by 456 · cited 2×
“In some setups, spatial variations in thickness of an adhesive pore-water film which forms directly below a protective foil covering the split core surface also have to be considered (Kido et al. 2006; Tjallingii et al. 2007).”
BackgroundMethodSelf-citationCompositional Data Analysis: Where Are We and Where Should We Be Heading?
Aitchison, J., & J. Egozcue, J. (2005) · Mathematical Geology · doi:10.1007/s11004-005-7383-7 · Cited by 379
New Techniques in Sediment Core Analysis
Rothwell, R. G. (2006) · ePrints Soton (University of Southampton) · Cited by 363
CORTEX, a shipboard XRF-scanner for element analyses in split sediment cores
Jansen, J. H. F., Van der Gaast, S. J., Koster, B., & Vaars, A. J. (1998) · Marine Geology · doi:10.1016/s0025-3227(98)00074-7 · Cited by 359 · cited 2×
“Progress in XRF instrumentation has opened the way to on-line measurement of (soft) sediment cores aboard ship by means of XRF-core-scanning devices (Jansen et al. 1998; Wien et al. 2005; Ge et al. 2005; Rothwell and Rack 2006).”
BackgroundMethodLöwemark, L., Chen, H.-F., Yang, T.-N., Kylander, M., Yu, E.-F., Hsu, Y.-W., Lee, T.-Q., Song, S.-R., & Jarvis, S. (2011) · Journal of Asian Earth Sciences · doi:10.1016/j.jseaes.2010.06.002 · Cited by 318 · cited 1×
“Although log-ratio transformations (Aitchison 1982, 1986) have not been widely applied to geochemical compositions and XRF core scanner output, several authors have pointed to the advantage of using ratios of element intensities (or concentrations) instead of intensities (or concentrations) of single elements (Croudac…”
Coherent high- and low-latitude control of the northwest African hydrological balance
Tjallingii, R., Claussen, M., Stuut, J.-B. W., Fohlmeister, J., Jahn, A., Bickert, T., Lamy, F., & Röhl, U. (2008) · Nature Geoscience · doi:10.1038/ngeo289 · Cited by 291 · cited 1×
“Detailed information about the sample preparation and the geological setting of the core may be found in Weltje and Tjallingii (2008), Tjallingii et al.”
BackgroundSelf-citationX‐Ray Fluorescence Spectrometry
Jenkins, R. (1999) · Wiley eBooks · doi:10.1002/9781118521014 · Cited by 235
Glacial/Interglacial Changes in Subarctic North Pacific Stratification
Jaccard, S. L., Haug, G. H., Sigman, D. M., Pedersen, T. F., Thierstein, H. R., & Röhl, U. (2005) · Science · doi:10.1126/science.1108696 · Cited by 222 · cited 1×
“Previous attempts to convert XRF core scanner output to element or oxide concentrations by means of linear regression on an element-byelement basis (referred to as direct linear calibration; DLC) have been only moderately successful (Jansen et al. 1998; Jaccard et al. 2005; Croudace et al. 2006; Kido et al. 2006; Böni…”
MethodSelf-citationRothwell, R. G., Hoogakker, B. A. A., Thomson, J., Croudace, I. W., & Frenz, M. (2006) · Geological Society London Special Publications · doi:10.1144/gsl.sp.2006.267.01.06 · Cited by 197 · cited 2×
“Although log-ratio transformations (Aitchison 1982, 1986) have not been widely applied to geochemical compositions and XRF core scanner output, several authors have pointed to the advantage of using ratios of element intensities (or concentrations) instead of intensities (or concentrations) of single elements (Croudac…”
BackgroundSelf-citationLate glacial to Holocene climate and sedimentation history in the NW Black Sea
Bahr, A., Lamy, F., Arz, H., Kuhlmann, H., & Wefer, G. (2005) · Marine Geology · doi:10.1016/j.margeo.2004.11.013 · Cited by 189 · cited 1×
“Down-core patterns of element-intensity ratios have proved extremely useful for correlation (e.g. Pälike et al. 2001; Vlag et al. 2004; Bahr et al. 2005), because they are unaffected by variations in the concentrations of other elements in a specimen (so-called dilution effects), which is especially relevant consideri…”
MethodNew techniques in sediment core analysis: an introduction
Rothwell, R. G., & Rack, F. R. (2006) · Geological Society, London, Special Publications · doi:10.1144/gsl.sp.2006.267.01.01 · Cited by 179
Ramsey, M. H., Potts, P. J., Webb, P., Watkins, P., Watson, J. S., & Coles, B. J. (1995) · Chemical Geology · doi:10.1016/0009-2541(95)00020-m · Cited by 151 · cited 1×
“X-ray fluorescence analysis (XRF) is a well-established technique for determining the composition of rocks and sediments (Ramsey et al. 1995; Jenkins 1999; De Vries and Vrebos 2002).”
MethodKido, Y., Koshikawa, T., & Tada, R. (2006) · Marine Geology · doi:10.1016/j.margeo.2006.03.002 · Cited by 133 · cited 2×
“In some setups, spatial variations in thickness of an adhesive pore-water film which forms directly below a protective foil covering the split core surface also have to be considered (Kido et al. 2006; Tjallingii et al. 2007).”
BackgroundMethodAstronomical forcing in Late Eocene marine sediments
Pälike, H., Shackleton, N. J., & Röhl, U. (2001) · Earth and Planetary Science Letters · doi:10.1016/s0012-821x(01)00501-5 · Cited by 116
Self-citationModelling the joint variability of grain size and chemical composition in sediments
Bloemsma, M. R., Zabel, M., Stuut, J.-B. W., Tjallingii, R., Collins, J. A., & Weltje, G. J. (2012) · Sedimentary Geology · doi:10.1016/j.sedgeo.2012.04.009 · Cited by 103 · cited 3×
“The usefulness of this empirical approach was demonstrated by Bloemsma et al. (2012), who showed that log-ratios of element intensities or concentrations obtained from bulk measurements do not provide universal shortcuts to palaeo-environmental interpretation, but are site-specific and should thus be validated before…”
BackgroundSelf-citationToward direct, micron‐scale XRF elemental maps and quantitative profiles of wet marine sediments
Böning, P., Bard, E., & Rose, J. (2007) · Geochemistry, Geophysics, Geosystems · doi:10.1029/2006gc001480 · Cited by 72 · cited 1×
“Previous attempts to convert XRF core scanner output to element or oxide concentrations by means of linear regression on an element-byelement basis (referred to as direct linear calibration; DLC) have been only moderately successful (Jansen et al. 1998; Jaccard et al. 2005; Croudace et al. 2006; Kido et al. 2006; Böni…”
MethodHaschke, M. (2006) · Geological Society London Special Publications · doi:10.1144/gsl.sp.2006.267.01.02 · Cited by 22
Description of a new Micro-XRay spectrometer
Haschke, M., Scholz, W., Theis, U., Nicolosi, J., Scruggs, B. E., & Herzceg, L. (2002) · Journal de Physique IV (Proceedings) · doi:10.1051/jp4:20020216 · Cited by 13
Cited by
(2015) · Developments in Paleoenvironmental Research · doi:10.1007/978-94-017-9849-5 · Cited by 419
Applications of geochemistry in tsunami research: A review
Chagué-Goff, C., Szczuciński, W., & Shinozaki, T. (2017) · Earth-Science Reviews · doi:10.1016/j.earscirev.2016.12.003 · Cited by 198
Grant, K. M., Rohling, E. J., Westerhold, T., Zabel, M., Heslop, D., Konijnendijk, T., & Lourens, L. (2017) · Quaternary Science Reviews · doi:10.1016/j.quascirev.2017.07.005 · Cited by 172
“We use a multivariate log-ratio calibration (Weltje et al., 2015) to convert the scanning XRF data into element concentrations, and then perform a principal component analysis on the calibrated XRF dataset (section 3).”
Self-citation
Metadata
- Authors
- Weltje, G. J., Bloemsma, M. R., Tjallingii, R., Heslop, D., Röhl, U., & Croudace, I. W.
- Venue
- Developments in Paleoenvironmental Research
- Publisher
- Springer Netherlands
- Published
- 2015
- Pages
- 507-534
- ISSN
- 1571-5299 (ISSN-L)
- 2215-1672
- OpenAlex
- W1816959357
- Cited by
- 230
- References
- 31
- FWCI
- 53.02
- Type
- book chapter
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.