Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 292

The DOI matches its Crossref record.

HVDC and FACTS Controllers

·2004·Power Electronics and Power Systems

Abstract

Preface. Acronyms. 1: Introduction to HVDC Transmission. 1.1. Introduction. 1.2. Comparison of AC-DC Transmission. 1.3. Types of HVDC Systems. 1.4. References. 2: Types of Converters. 2.1. Introduction. 2.2. Current Source Converters (CSC). 2.3. Voltage Source Converters (VSC). 2.4. Closing Remarks. 2.5. References. 3: Synchronization Techniques for Power Converters. 3.1. Introduction. 3.2. Review of GFUs. 3.3. GFUs - Design And Analysis. 3.4. Tests On GFUs. 3.5. EMTP Simulation Of A Test System. 3.6. Conclusions. 3.7. Acknowledgement. 3.8. References. 4: HVDC Controls. 4.1. Historical Background. 4.2. Functions of HVDC Controls. 4.3. Control Basics for a Two-terminal DC Link. 4.4. Current Margin Control Method. 4.5. Current Control at the Rectifier. 4.6. Inverter Extinction Angle Control. 4.7. Hierarchy of Controls. 4.8. Action By Controls After a Disturbance. 4.9. References. 5: Forced Commutated HVDC Converters. 5.1. Introduction. 5.2. Commutation Techniques for HVDC Converters. 5.3. Examples of FC Converters for HVDC Transmission. 5.4. References. 6: Capacitor Commutated Converters for HVDC Systems. 6.1. Capacitor Commutated Converters (CCC). 6.2. Controlled Series Capacitor Converter (CSCC). 6.3. Comparison of CCC and CSCC. 6.4. Garabi Interconnection between Argentina-Brazil. 6.5. Closing Remarks. 6.6. Acknowledgement. 6.7. References. 7: Static Compensators: STATCOM Based on Chain-Link Converters. 7.1. Introduction. 7.2. The Chainlink Converter. 7.3. Advantages of the Chain Circuit STATCOM. 7.4. Design for Production. 7.5. Acknowledgement. 7.6. References. 8: HVDC Systems Using Voltage Source Converters. 8.1. Introduction. 8.2. Basic Elements of HVDC using VSCs. 8.3. Voltage Source Converter. 8.4. Applications. 8.5. Tjaereborg Windpower Project in Denmark. 8.6. Power Supply to Remote Locations (i.e. Islands). 8.7. Asynchronous Inter-Connections. 8.8. Concluding Remarks. 8.9. Acknowledgement. 8.10. References. 9: Active Filters. 9.1. Introduction. 9.2. DC Filters. 9.3. AC Filters. 9.4. Concluding Remarks. 9.5. Acknowledgement. 9.6. References. 10: Typical Disturbances in HVDC Systems. 10.1. Introduction. 10.2. CIGRE Benchmark Model for HVDC Control Studies. 10.3. Details of Control Systems Used. 10.4. Results. 10.5. Closing Remarks. 10.6. Acknowledgement. 10.7. References. 11: Advanced Controllers. 11.1. Introduction. 11.2. Application of an Advanced VDCL Unit. 11.3. Conclusions. 11.4. Acknowledgement. 11.5. References. 12: Measurement/Monitoring Aspects. 12.1. Introduction.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/b117759

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 292

Metadata

Venue
Power Electronics and Power Systems
Published
2004
OpenAlex
W571583956
Cited by
292
References
0
FWCI
5.56
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: HVDC and FACTS Controllers. https://app.cochat.ai/papers/10.1007/b117759
The paper
HVDC and FACTS Controllers. (2004). Power Electronics and Power Systems. https://doi.org/10.1007/b117759

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.