Minimizing the effects of radio-frequency heating in multidimensional NMR experiments
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Application of radio-frequency power in multidimensional NMR experiments can significantly increase the sample temperature compared to that of the surrounding gas flow. Radio-frequency heating effects become more severe at higher magnetic field strengths and ionic strengths. The effects are particularly noticeable for experiments that utilize 1H and/or 13C isotropic mixing and broadband decoupling. If radio-frequency power is applied during the systematically increasing evolution period t1, the sample temperature can change with t1 and thereby cause line-shape distortions. Such distortions are easily avoided by ensuring that the average radio-frequency power remains constant during the entire experiment.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Since the degree of alignment for bicelles samples is highly sensitive to temperature changes41–43, these temperature variations affect both sample stability and spectral quality.”
From Improving the quality of oriented membrane protein spectra using heat-compensated separated local field experiments (2019) · cites this paper as [42]
Citations
Cites
Iterative schemes for bilinear operators; application to spin decoupling
Shaka, A. J., Lee, C. J., & Pines, A. (1988) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(88)90178-3 · Cited by 745
Bax, A., Clore, G. M., & Gronenborn, A. M. (1990) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(90)90202-k · Cited by 584
Self-citation
Cited by
Gor’kov, P. L., Chekmenev, E. Y., Li, C., Cotten, M., Buffy, J. J., Traaseth, N. J., Veglia, G., & Brey, W. W. (2007) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2006.11.008 · Cited by 213
Measurement of 15N relaxation rates in perdeuterated proteins by TROSY-based methods
Lakomek, N.-A., Ying, J., & Bax, A. (2012) · Journal of Biomolecular NMR · doi:10.1007/s10858-012-9626-5 · Cited by 213
“To ensure that the same RF heating applies in the R1 and R1q experiments, immediately following data acquisition, a 15N temperature compensation pulse (Wang and Bax 1993) is applied that corresponds to the longest spin-lock time and RF power of the R1q experiment (see below).”
MethodSelf-citationNMR studies of Brownian tumbling and internal motions in proteins
Korzhnev, D. M., Billeter, M., Arseniev, A. S., & Orekhov, V. Y. (2001) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/s0079-6565(00)00028-5 · Cited by 209
Wang, S., Gopinath, T., & Veglia, G. (2019) · Journal of Biomolecular NMR · doi:10.1007/s10858-019-00273-1 · Cited by 6
Metadata
- Authors
- Wang, A., & Bax, A.
- Venue
- Journal of Biomolecular NMR
- Published
- 1993-11
- Volume
- 3
- Issue
- 6
- ISSN
- 0925-2738
- 1573-5001
- Cited by
- 58
- References
- 2
- Language
- en
- Licence
- www.springer.com/tdm (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Minimizing the effects of radio-frequency heating in multidimensional NMR experiments. https://app.cochat.ai/papers/10.1007/bf00198374
- The paper
- Wang, A., & Bax, A. (1993). Minimizing the effects of radio-frequency heating in multidimensional NMR experiments. Journal of Biomolecular NMR. https://doi.org/10.1007/bf00198374
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.