Oxygen supply and uptake in the liver and the intestine
Abstract
The oxygen supply to the liver was found to be dependent on the total blood flow only and not on the ratio of arterial to portal contribution. The mean value of O2-uptake in the liver, related to a blood flow of 110 ml/min - 100 g liver, amounted to 6.08 +/- 0.2 ml O2/min - 100 g liver (mean +/- S.E.M.). O2-uptake of the intestine was found to be 1.95 +/- 0.13 ml O2/min - 100 g tissue, related to a normal blood flow of 50 ml/min - 100 g tissue. With low oxygen supply O2 extraction in the liver reaches values of 97%, whereas the intestinal extraction does not surpass 75%. A rise in oxygen supply surmounting normal values does not increase the O2-consumption. Contrary to the intestinal circulation the liver showed no postocclusive vasodilatation. The oxygen debt was payed back by a greater extraction. The portal oxygen supply to the liver can markedly increase due to intestinal metabolic hyperemia. High O2-extraction capacity, rather than vasodilatation, is the main mechanism for matching hepatic oxygen supply with requirements. The hepatic venous blood may leave the liver with an extremely low O2-content.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The oxygen consumption rate in human liver is reported to be 0.06 mL g-1 min-1, corresponding to 4 × 10-8 mol cm-3 s-1 for an approximate liver mass density of 1 g cm-3.
“The oxygen consumption rate in human liver is reported to be 0.06 mL g -1 min -1 [28] , corresponding to 4 × 10 -8 mol cm -3 s -1 for an approximate liver mass density of 1 g cm -3 .”
From 3D microperfusion of mesoscale human microphysiological liver models improves functionality and recapitulates hepatic zonation (2023) · cites this paper as [28]
Cited by
Sorted by citations
Wesseler, M. F., Taebnia, N., Harrison, S., Youhanna, S., Preiss, L. C., Kemas, A. M., Vegvari, A., Mokry, J., Sullivan, G. J., Lauschke, V. M., et al. (2023) · Acta Biomaterialia · doi:10.1016/j.actbio.2023.09.022 · Cited by 39 · see citing works
- Authors
- Lutz, J., Henrich, H., & Bauereisen, E.
- Venue
- Pfl�gers Archiv European Journal of Physiology
- Published
- 1975
- Volume
- 360
- Issue
- 1
- Pages
- 7-15
- ISSN
- 0031-6768
- 1432-2013
- Cited by
- 70
- References
- 0
- Language
- en
- Licence
- www.springer.com/tdm (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review