The DOI matches its Crossref record.
Die Messung der magnetischen Spannung: Messung des Linienintegrals der magnetischen Feldstärke
Open accessOverview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Induction coil sensors—a review
Tumanski, S. (2007) · Measurement Science and Technology · doi:10.1088/0957-0233/18/3/r01 · Cited by 590
Using Rogowski coils for transient current measurements
Ward, D. A., & Exon, J. L. T. (1993) · Engineering Science and Education Journal · doi:10.1049/esej:19930034 · Cited by 280
Bortis, D., Biela, J., & Kolar, J. W. (2008) · IEEE Transactions on Plasma Science · doi:10.1109/tps.2008.2003971 · Cited by 127
Kirkici, H., Rose, M. F., & Chaloupka, T. (1996) · IEEE Transactions on Dielectrics and Electrical Insulation · doi:10.1109/94.485523 · Cited by 23
Metadata
- Authors
- Rogowski, W., & Steinhaus, W.
- Venue
- Archiv für Elektrotechnik
- Published
- 1912-04
- Volume
- 1
- Issue
- 4
- Pages
- 141-150
- ISSN
- 0003-9039 (ISSN-L)
- 1432-0487
- OpenAlex
- W2576921197
- Cited by
- 238
- References
- 0
- FWCI
- 0.00
- Type
- journal article
- Language
- de
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.