Detection of fast neuronal signals in the motor cortex from functional near infrared spectroscopy measurements using independent component analysis
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Fast changes, in the range of milliseconds, in the optical properties of cerebral tissue are associated with brain activity and can be detected using noninvasive near-infrared spectroscopy (NIRS). These changes are assumed to be caused by changes in the light scattering properties of the neuronal tissue. The aim of this study was to develop highly sensitive data analysi algorithms to detect this fast signal, which is small compared with other physiological signals. A frequency-domain tissue oximeter, whose laser diodes were intensity modulated at 110 MHz, was used. The amplitude, mean intensity and phase of the modulated optical signal were measured at a sample rate of 96 Hz. The probe, consisting of four crossed source detector pairs was placed above the motor cortex, contralateral to the hand performing a tapping exercise consisting of alternating rest and tapping periods of 20 s each. An adaptive filter was used to remove the arterial pulsatility from the optical signals. Independent component analysis allowed further separation of a signal component containing the fast signal. In nine out of 14 subjects, a significant fast neuronal signal related to the finger tapping was found in the intensity signals. In the phase signals, indications of the fast signal were found in only two subjects.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Information-Maximization Approach to Blind Separation and Blind Deconvolution
Bell, A. J., & Sejnowski, T. J. (1995) · Neural Computation · doi:10.1162/neco.1995.7.6.1129 · Cited by 8,986
Report of the committee on methods of clinical examination in electroencephalography
(1958) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(58)90053-1 · Cited by 2,717
Separation of a mixture of independent signals using time delayed correlations
Molgedey, L., & Schuster, H. G. (1994) · Physical Review Letters · doi:10.1103/physrevlett.72.3634 · Cited by 882 · cited 2×
“For temporally correlated signals, however, the time dependence structure can be exploited, and U can also be retrieved from covariance matrices at non-zero lags (hence, using only second-order statistics) (BELOUCHRANI et al., 1997; ZlEHE and MOLLER, 1998; MOLGEDEY and SCHUSTER, 1994).”
BackgroundMethod
Cited by
Scholkmann, F., Kleiser, S., Metz, A. J., Zimmermann, R., Mata Pavia, J., Wolf, U., & Wolf, M. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.004 · Cited by 2,002
Self-citationProgress of near-infrared spectroscopy and topography for brain and muscle clinical applications
Ferrari, M. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2804899 · Cited by 600
An Efficient Algorithm for Automatic Peak Detection in Noisy Periodic and Quasi-Periodic Signals
Scholkmann, F., Boss, J., & Wolf, M. (2012) · Algorithms · doi:10.3390/a5040588 · Cited by 453
Self-citationHerold, F., Wiegel, P., Scholkmann, F., Thiers, A., Hamacher, D., & Schega, L. (2017) · Neurophotonics · doi:10.1117/1.nph.4.4.041403 · Cited by 314
Quaresima, V., Bisconti, S., & Ferrari, M. (2012) · Brain and Language · doi:10.1016/j.bandl.2011.03.009 · Cited by 276
Metadata
- Authors
- Morren, G., Wolf, M., Lemmerling, P., Wolf, U., Choi, J. H., Gratton, E., De Lathauwer, L., & Van Huffel, S.
- Venue
- Medical and Biological Engineering and Computing
- Published
- 2004-01
- Volume
- 42
- Issue
- 1
- Pages
- 92-99
- ISSN
- 0140-0118 (ISSN-L)
- 1741-0444
- OpenAlex
- W1989784044
- Cited by
- 122
- References
- 3
- FWCI
- 2.94
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.