The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
The determination of peroxide value by fourier transform infrared spectroscopy
Abstract
A rapid method for the quantitative determination of peroxide value (PV) of vegetable oils by Fourier transform infrared (FTIR) transmission spectroscopy is described. Calibration standards were prepared by the addition of t‐butyl hydroperoxide to a series of vegetable oils, along with random amounts of oleic acid and water. Additional standards were derived through the addition of mono‐ and diglyceride spectral contributions, as well as zero PV spectra obtained from deuterated oils. A partial least squares (PLS) calibration model for the prediction of PV was developed based on the spectral range 3750–3150 cm−1. Validation of the method was carried out by comparing the PV of a series of vegetable oils predicted by the PLS model to the values obtained by the American Oil Chemists Society iodometric method. The reproducibility of the FTIR method [coefficient of variation (CV)=5%)] was found to be better than that of the chemical method (CV =9%), although its accuracy was limited by the reproducibility of the chemical method. The method, as structured, makes use of a 1‐mm CaF 2 flow cell to allow rapid sample handling by aspiration. The spectrometer was preprogrammed in Visual Basic to guide the operator in performing the analysis so that no knowledge of FTIR spectroscopy is required to implement the method. The method would be suitable for PV determinations in the edible oil industry and takes an average of three minutes per sample.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fourier Transform Infrared Spectrometry
Griffiths, P. R., & de Haseth, J. A. (2007) · doi:10.1002/047010631x · Cited by 3,052
Cited by
Methods for testing antioxidant activity
Antolovich, M., Prenzler, P. D., Patsalides, E., McDonald, S., & Robards, K. (2002) · The Analyst · doi:10.1039/b009171p · Cited by 1,301
Identification and quantification of valuable plant substances by IR and Raman spectroscopy
Schulz, H., & Baranska, M. (2007) · Vibrational Spectroscopy · doi:10.1016/j.vibspec.2006.06.001 · Cited by 975
Vegetable oil-based lubricants—A review of oxidation
Fox, N. J., & Stachowiak, G. W. (2007) · Tribology International · doi:10.1016/j.triboint.2006.10.001 · Cited by 763
Laguerre, M., Lecomte, J., & Villeneuve, P. (2007) · Progress in Lipid Research · doi:10.1016/j.plipres.2007.05.002 · Cited by 706
Guillén, M. D., & Cabo, N. (1997) · Journal of the American Oil Chemists' Society · doi:10.1007/s11746-997-0058-4 · Cited by 425
Karoui, R., Downey, G., & Blecker, C. (2010) · Chemical Reviews · doi:10.1021/cr100090k · Cited by 405
Guillén, M. D., & Cabo, N. (2002) · Food Chemistry · doi:10.1016/s0308-8146(01)00371-5 · Cited by 392
Metadata
- Authors
- van de Voort, F. R., Ismail, A. A., Sedman, J., Dubois, J., & Nicodemo, T.
- Venue
- Journal of the American Oil Chemists' Society
- Publisher
- Wiley
- Published
- 1994-09
- Volume
- 71
- Issue
- 9
- Pages
- 921-926
- ISSN
- 0003-021X (ISSN-L)
- 1558-9331
- OpenAlex
- W2013767890
- Cited by
- 186
- References
- 1
- FWCI
- 4.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.