Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 186

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

The determination of peroxide value by fourier transform infrared spectroscopy

van de Voort, F. R., Ismail, A. A., Sedman, J., Dubois, J., Nicodemo, T.·1994·Journal of the American Oil Chemists' Society

Abstract

A rapid method for the quantitative determination of peroxide value (PV) of vegetable oils by Fourier transform infrared (FTIR) transmission spectroscopy is described. Calibration standards were prepared by the addition of t‐butyl hydroperoxide to a series of vegetable oils, along with random amounts of oleic acid and water. Additional standards were derived through the addition of mono‐ and diglyceride spectral contributions, as well as zero PV spectra obtained from deuterated oils. A partial least squares (PLS) calibration model for the prediction of PV was developed based on the spectral range 3750–3150 cm−1. Validation of the method was carried out by comparing the PV of a series of vegetable oils predicted by the PLS model to the values obtained by the American Oil Chemists Society iodometric method. The reproducibility of the FTIR method [coefficient of variation (CV)=5%)] was found to be better than that of the chemical method (CV =9%), although its accuracy was limited by the reproducibility of the chemical method. The method, as structured, makes use of a 1‐mm CaF 2 flow cell to allow rapid sample handling by aspiration. The spectrometer was preprogrammed in Visual Basic to guide the operator in performing the analysis so that no knowledge of FTIR spectroscopy is required to implement the method. The method would be suitable for PV determinations in the edible oil industry and takes an average of three minutes per sample.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/bf02542254

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
van de Voort, F. R., Ismail, A. A., Sedman, J., Dubois, J., & Nicodemo, T.
Venue
Journal of the American Oil Chemists' Society
Publisher
Wiley
Published
1994-09
Volume
71
Issue
9
Pages
921-926
ISSN
  • 0003-021X (ISSN-L)
  • 1558-9331
OpenAlex
W2013767890
Cited by
186
References
1
FWCI
4.84
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.