The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Rapid quantitative determination of free fatty acids in fats and oils by fourier transform infrared spectroscopy
Abstract
Rapid direct and indirect Fourier transform infrared (FTIR) spectroscopic methods were developed for the determination of free fatty acids (FFA) in fats and oils based on both transmission and attenuated total reflectance approaches, covering an analytical range of 0.2–8% FFA. Calibration curves were prepared by adding oleic acid to the oil chosen for analysis and measuring the C=O band @ 1711 cm–1 after ratioing the sample spectrum against that of the same oil free of fatty acids. For fats and oils that may have undergone significant thermal stress or extensive oxidation, an indirect method was developed in which 1% KOH/methanol is used to extract the FFAs and convert them to their potassium salts. The carboxylate anion absorbs @ 1570 cm–1, well away from interfering absorptions of carbonyl‐containing oxidation end products that are commonly present in oxidized oils. Both approaches gave results comparable in precision and accuracy to that of the American Oil Chemists’ Society reference titration method. Through macroprogramming, the FFA analysis procedure was completely automated, making it suitable for routine quality control applications. As such, the method requires no knowledge of FTIR spectroscopy on the part of the operator, and an analysis takes less than 2 min.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fourier Transform Infrared Spectrometry
Griffiths, P. R., & de Haseth, J. A. (2007) · doi:10.1002/047010631x · Cited by 3,052
Cited by
Guillén, M. D., & Cabo, N. (1997) · Journal of the American Oil Chemists' Society · doi:10.1007/s11746-997-0058-4 · Cited by 425
Metadata
- Authors
- Ismail, A. A., van de Voort, F. R., Emo, G., & Sedman, J.
- Venue
- Journal of the American Oil Chemists' Society
- Publisher
- Wiley
- Published
- 1993-04
- Volume
- 70
- Issue
- 4
- Pages
- 335-341
- ISSN
- 0003-021X (ISSN-L)
- 1558-9331
- OpenAlex
- W1976518827
- Cited by
- 186
- References
- 1
- FWCI
- 5.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.