Évaluation de la qualité des podomètres commerciaux
Open accessAbstract
Background The purpose of this study was to: 1) evaluate the quality of promotional pedometers widely distributed through cereal boxes at the time of the 2004 Canada on the Move campaign; and 2) establish a battery of testing protocols to provide direction for future consensus on industry standards for pedometer quality.Methods Fifteen Kellogg's* Special K* Step Counters (K pedometers or K; manufactured for Kellogg Canada by Sasco, Inc.) and 9 Yamax pedometers (Yamax; Yamax Corporation, Tokyo, Japan) were tested with 9 participants accordingly: 1) 20 Step Test; 2) treadmill at 80m x min(-1) (3 miles x hr(-1)) and motor vehicle controlled conditions; and 3) 24-hour free-living conditions against an accelerometer criterion.Results Fifty-three percent of the K pedometers passed the 20 Step Test compared to 100% of the Yamax. Mean absolute percent error for the K during treadmill walking was 24.2+/-33.9 vs. 3.9+/-6.6% for the Yamax. The K detected 5.7-fold more non-steps compared to the Yamax during the motor vehicle condition. In the free-living condition, mean absolute percent error relative to the ActiGraph was 44.9+/-34.5% for the K vs. 19.5+/-21.2% for the Yamax.Conclusions K pedometers are unacceptably inaccurate. We suggest that research grade pedometers: 1) be manufactured to a sensitivity threshold of 0.35 Gs; 2) detect +/-1 step error on the 20 Step Test (i.e., within 5%); 3) detect +/-1% error most of the time during treadmill walking at 80m x min(-1) (3 miles x hr(-1)); as well as, 4) detect steps/day within 10% of the ActiGraph at least 60% of the time, or be within 10% of the Yamax under free-living conditions.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Pedometer models differ in computed steps when worn concurrently.
“and differences in computed steps when models were worn concurrently [106].”
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
The citation lists haven’t been fetched yet
References 27 · Cited by 142
Research works printed but not linked: 1
- Le Masurier G. Pedometer sensitivity and speci- ficity. Med Sci Sports Exerc 2004;36(2):347.
- Authors
- Tudor-Locke, C., Sisson, S. B., Lee, S. M., Craig, C. L., Plotnikoff, R. C., & Bauman, A.
- Affiliations
- Canadian Fitness and Lifestyle Research Institute (CA)
- Arizona State University (US)
- University of Alberta (CA)
- The University of Sydney (AU)
- Venue
- Canadian Journal of Public Health
- Published
- 2006-03
- Volume
- 97
- Issue
- S1
- Pages
- S10-S16
- ISSN
- 0008-4263 (ISSN-L)
- 1920-7476
- PMC
- PMC6975901
- OpenAlex
- W1601572263
- Cited by
- 142
- References
- 27
- Citations by year
- 2026: 3 · 2025: 3 · 2024: 4 · 2023: 1 · 2022: 3 · 2021: 8 · 2020: 5 · 2019: 10 · 2018: 8 · 2017: 8 · 2016: 15 · 2015: 8 · 2014: 8 · 2013: 12 · 2012: 9
- FWCI
- 5.30
- Type
- journal article
- Language
- fr
- Open access
- bronze
- doi.org
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Canadian Journal of Public Health (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Canadian Institutes of Health Research
- Topics
- Health Sciences › Medicine › Physiology › Physical Activity and Health
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Health Sciences › Health Professions › General Health Professions › Mobile Health and mHealth Applications
- Keywords
- pedometers, step count accuracy, treadmill walking, physical activity measurement
- MeSH terms
- Adult, Canada, Equipment Design, Female, Humans, Monitoring, Physiologic, Exercise, Walking
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review