kV Cone-Beam CT-Based IGRT: A Clinical Review
Open accessThe DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
AbstractAims and Methods:Delivery of high radiation doses while simultaneously sparing organs at risk requires advanced imaging for target volume definition, highly conformal dose distributions of intensity modulated radiotherapy (IMRT), and narrow planning target volume (PTV) margins. Three-dimensional image-guided radiotherapy (IGRT) with cone-beam computer tomography (CBCT), which results in more precise target localization, is quickly replacing two-dimensional (2D) IGRT. An overview on the clinical applications of kilovoltage gantry-mounted CBCT systems with emphasis on the most frequently targeted body sites (prostate, lung, head and neck) is provided based on a review of the relevant literature. Alternative imaging methods and their advantages/disadvantages are discussed.Results:IGRT with soft tissue detection improves set-up accuracy and is currently replacing 2D verification and frame-based stereotactic treatments; safety margins are significantly reduced by this IGRT technology. In addition, systematic changes of tumor volume and shape and of the normal tissue can be monitored allowing for adaptation of radiotherapy. IGRT in combination with conformal treatment planning allows for hypofractionated dose escalation, which results in improved rates of local tumor control with low rates of toxicity.Conclusion:CBCT allows for daily pretreatment position verification and online correction of set-up errors which improves the precision of patient repositioning with the possibility of shrinking safety margins, sparing organs at risk, and escalating radiation doses. A trend for better clinical outcome can be observed.ZusammenfassungHintergrund und Methodik:Die Verwendung von eskalierten Bestrahlungsdosen bei gleichzeitiger Schonung der Risikoorgane setzt multimodale Bildgebung zur Zielvolumendefinition, hochkonformale Bestrahlungsplanung mittels intensitätsmodulierter Radiotherapie und enge Sicherheitssäume voraus. Bildgeführte Strahlentherapie (IGRT) dient der präzisen Lokalisation des Zielvolumens, und konventionelle 2D Techniken wie Feldkontrollaufnahmen werden aktuell insbesondere durch dreidimensionale Cone-beam-(CBCT-)Technik ersetzt. Dieser Artikel gibt einen Literaturüberblick über den aktuellen Stand der IGRT mittels CBCT. Schwerpunkte sind die praktische Anwendung und klinischen Resultate bei Prostatakarzinom, Bronchialkarzinom und Kopf-Hals-Tumoren. Ergebnisse: Schlussfolgerungen: Schlüsselwörter: Ergebnisse:IGRT mittels CBCT ist hocheffektiv zur Verifikation der Patientenpositionierung und insbesondere zur Verifikation der Tumorposition. Rahmenbasierte Stereotaxie kann durch IGRT ersetzt werden, sowohl kraniell als auch extrakraniell. Bei Verwendung von IGRT-Techniken ohne ausreichenden Weichteilkontrast müssen größere Sicherheitssäume verwendet werden, um ein Verfehlen des Zielvolumens zu vermeiden. Zusätzlich sind mittels 3D IGRT systematische Veränderungen von Tumorvolumen, Tumorform und Lagebeziehung zu Risikoorganen darstellbar, was zur Adaption des Bestrahlungsplanes genutzt werden kann. Mittels konformaler IMRT-Bestrahlungstechniken und präziser IGRT konnten hypofraktionierte, eskalierte Bestrahlungsdosen sicher appliziert werden, was in verbesserter lokaler Tumorkontrolle ohne erhöhte Toxizität resultierte.Schlussfolgerungen:CBCT ermöglicht die Verifikation der Tumorposition zur Online-Korrektur von Positionsfehlern vor der Behandlung, was die Anwendung von kleinen Sicherheitssäumen, Normalgewebsschonung und Dosiseskalation ermöglicht. Die Verbesserung klinischer Ergebnisse wird durch diese Techniken erwartet und ist z.T. bereits in der Literatur dokumentiert.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
1 retracted
Rowell, N. P., & Williams, C. (2001) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd002935 · Cited by 113
RetractedStereotactic Body Radiation Therapy for Inoperable Early Stage Lung Cancer
Timmerman, R. (2010) · JAMA · doi:10.1001/jama.2010.261 · Cited by 2,532
Flat-panel cone-beam computed tomography for image-guided radiation therapy
Jaffray, D. A., Siewerdsen, J. H., Wong, J. W., & Martinez, A. A. (2002) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(02)02884-5 · Cited by 1,330 · cited 1×
“Of all IGRT solutions, CBCT is being installed at the fastest pace [41].”
BackgroundLong-term results of the M.D. Anderson randomized dose-escalation trial for prostate cancer
Kuban, D. A., Tucker, S. L., Dong, L., Starkschall, G., Huang, E. H., Cheung, M. R., Lee, A. K., & Pollack, A. (2008) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2007.06.054 · Cited by 1,232 · cited 1×
“2 Gy [2, 18, 44, 84].”
Zietman, A. L., DeSilvio, M. L., Slater, J. D., Rossi, C. J., Miller, D. W., Adams, J. A., & Shipley, W. U. (2005) · JAMA · doi:10.1001/jama.294.10.1233 · Cited by 1,224 · cited 1×
“2 Gy [2, 18, 44, 84].”
Dearnaley, D. P., Sydes, M. R., Graham, J. D., Aird, E. G., Bottomley, D., Cowan, R. A., Huddart, R. A., Jose, C. C., Matthews, J. H., Millar, J., et al. (2007) · The Lancet Oncology · doi:10.1016/s1470-2045(07)70143-2 · Cited by 905
Yan, T. D., Black, D., Bannon, P. G., & McCaughan, B. C. (2009) · Journal of Clinical Oncology · doi:10.1200/jco.2008.18.2733 · Cited by 725 · cited 1×
“Rationale for IGRT Although radiotherapy is accepted as the treatment of choice for medically inoperable early stage non-small cell lung cancer (NSCLC), rates of local control are disappointing with conventional techniques/fractionation (local failure in 6–70% stage I/ II patients [62] which is substantially higher th…”
BackgroundOnishi, H., Shirato, H., Nagata, Y., Hiraoka, M., Fujino, M., Gomi, K., Karasawa, K., Hayakawa, K., Niibe, Y., Takai, Y., et al. (2011) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2009.07.1751 · Cited by 619 · cited 1×
“Overall survival approaches best surgical results for SBRT in operable patients refusing surgery [56].”
BackgroundCone-beam computed tomography with a flat-panel imager: Magnitude and effects of x-ray scatter
Siewerdsen, J. H., & Jaffray, D. A. (2001) · Medical Physics · doi:10.1118/1.1339879 · Cited by 612 · cited 1×
“Image Quality CBCT image quality is inferior to diagnostic fan-beam CTs due to increased scatter (also contributing to streaking/cupping artifacts [63]) and reduced contrast of large projection field sizes [29].”
Backgroundvan Herk, M., Bruce, A., Guus Kroes, A. P., Shouman, T., Touw, A., & Lebesque, J. V. (1995) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/0360-3016(95)00116-6 · Cited by 518 · cited 1×
“Translational prostate position variability is largest in anterior–posterior and superior–inferior directions and AP prostate motion is mainly explained by the rotation of the prostate around the LR axis at the apex [28, 76].”
BackgroundKupelian, P., Willoughby, T., Mahadevan, A., Djemil, T., Weinstein, G., Jani, S., Enke, C., Solberg, T., Flores, N., Liu, D., et al. (2007) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2006.10.026 · Cited by 490 · cited 1×
“Online position correction can be performed with CT-on-rails or conebeam CT (CBCT), ultrasound [26] or electromagnetic signals [46].”
BackgroundUpdate of Dutch Multicenter Dose-Escalation Trial of Radiotherapy for Localized Prostate Cancer
Al-Mamgani, A., van Putten, W. L. J., Heemsbergen, W. D., van Leenders, G. J. L. H., Slot, A., Dielwart, M. F. H., Incrocci, L., & Lebesque, J. V. (2008) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2008.02.073 · Cited by 415 · cited 1×
“2 Gy [2, 18, 44, 84].”
de Crevoisier, R., Tucker, S. L., Dong, L., Mohan, R., Cheung, R., Cox, J. D., & Kuban, D. A. (2005) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2004.11.032 · Cited by 389 · cited 1×
“Rationale for IGRT In prostate cancer, decreased biochemical control rates were reported for patients with a distended rectum in the planning CT [16], a situation not representative for the treatment course resulting in a systematic posterior displacement of the prostate.”
BackgroundPurdie, T. G., Bissonnette, J., Franks, K., Bezjak, A., Payne, D. G., Sie, F., Sharpe, M. B., & Jaffray, D. A. (2007) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2006.12.022 · Cited by 371 · cited 1×
“These errors increase with time, particularly if the treatment fraction exceeds 30 min [59].”
BackgroundIslam, M. K., Purdie, T. G., Norrlinger, B. D., Alasti, H., Moseley, D. J., Sharpe, M. B., Siewerdsen, J. H., & Jaffray, D. A. (2006) · Medical Physics · doi:10.1118/1.2198169 · Cited by 313 · cited 1×
“Extra Dose Due to Imaging The CBCT dose is 20 mGy/scan for pelvic and < 10 mGy/scan for head and neck imaging (in vivo measurements [40, 78]).”
BackgroundMoseley, D. J., White, E. A., Wiltshire, K. L., Rosewall, T., Sharpe, M. B., Siewerdsen, J. H., Bissonnette, J., Gospodarowicz, M. K., Warde, P. R., Catton, C., et al. (2007) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2006.10.039 · Cited by 304 · cited 1×
“Manual registration of planning CT and CBCT without implanted markers resulted in interobserver variability with errors > 2 mm [55].”
BackgroundLiao, Z. X., Komaki, R. R., Thames, H. D., Liu, H. H., Tucker, S. L., Mohan, R., Martel, M. K., Wei, X., Yang, K., Kim, E. S., et al. (2010) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2009.02.032 · Cited by 282 · cited 1×
“[51] reported decreased rates of severe pneumonitis and improved survival in patients treated with advanced technologies.”
BackgroundDose–volume effects for normal tissues in external radiotherapy: Pelvis
Fiorino, C., Valdagni, R., Rancati, T., & Sanguineti, G. (2009) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2009.08.004 · Cited by 273 · cited 1×
“Consequences of large TVs and suboptimally conformal dose distributions were increased rates of especially late rectal toxicity [25].”
BackgroundBhide, S. A., Davies, M., Burke, K., et al. (2010) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2009.04.005 · Cited by 244 · cited 1×
“Patient weight loss and shrinkage of head and neck tumors and salivary glands is frequently observed during radio(chemo) therapy [12, 4].”
BackgroundDearnaley, D. P., Hall, E., Lawrence, D., Huddart, R. A., Eeles, R., Nutting, C. M., Gadd, J., Warrington, A., Bidmead, M., & Horwich, A. (2005) · British Journal of Cancer · doi:10.1038/sj.bjc.6602301 · Cited by 230 · cited 1×
“CTV-to-PTV safety margins of at least 10 mm are commonly accepted [17, 19].”
BackgroundAdaptive Radiotherapy for Lung Cancer
Sonke, J.-J., & Belderbos, J. (2010) · Seminars in Radiation Oncology · doi:10.1016/j.semradonc.2009.11.003 · Cited by 226 · cited 1×
“Changes of atelectasis and pleural effusion have been reported in almost 50% of patients [64], altering shape and position of the TV.”
BackgroundEngels, B., Soete, G., Verellen, D., & Storme, G. (2009) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2008.08.007 · Cited by 162 · cited 1×
“Decreased biochemical control was reported when marker-based IGRT was practiced compared to IGRT using pelvic bones [23].”
MethodInclusion of organ deformation in dose calculations
Brock, K. K., McShan, D. L., Haken, R. K. T., Hollister, S. J., Dawson, L. A., & Balter, J. M. (2003) · Medical Physics · doi:10.1118/1.1539039 · Cited by 146 · cited 1×
“All adaptive replanning strategies require deformable image registration for dosimetric evaluation and correction of complex anatomical changes [11], still an area of research.”
BackgroundGückenberger, M., Krieger, T., Richter, A., Baier, K., Wilbert, J., Sweeney, R. A., & Flentje, M. P. (2008) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2008.08.010 · Cited by 129 · cited 3×
“Treatment in free breathing is appropriate for motion amplitudes less than 10–15 mm [32].”
BackgroundSelf-citationGückenberger, M., Meyer, J., Wilbert, J., Baier, K., Mueller, G., Wulf, J., & Flentje, M. P. (2006) · Acta Oncologica · doi:10.1080/02841860600904839 · Cited by 126 · cited 1×
“Soft tissue-based image-guided radiotherapy (IGRT) is currently replacing two-dimensional (2D) verification and frame-based intra- [8] and extracranial stereotaxy [34].”
BackgroundSelf-citationChung, H. T.-K., Xia, P., Chan, L. W., Park-Somers, E., & Roach, M. (2008) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2008.03.015 · Cited by 122 · cited 1×
“Clinical Results There is no high-evidence level data that IGRT improves outcome for prostate cancer, but promising retrospective studies reported decreased toxicity when IGRT was added to radiotherapy [9, 14] and multiple studies reported low toxicity rates when IGRT/IMRT were practiced in dose escalation [35].”
BackgroundGückenberger, M., Wilbert, J., Richter, A., Baier, K., & Flentje, M. P. (2010) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2010.04.050 · Cited by 119 · cited 1×
“Weeks: Tumor regression of about 1–2%/day is observed during fractionated radiotherapy [32, 37].”
BackgroundSelf-citationCastadot, P., Geets, X., Lee, J. A., Christian, N., & Grégoire, V. (2010) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2010.03.007 · Cited by 118
Rowell, N. P., & Williams, C. (2015) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd002935.pub2 · Cited by 101
Reliability of the Bony Anatomy in Image-Guided Stereotactic Radiotherapy of Brain Metastases
Gückenberger, M., Baier, K., Guenther, I., Richter, A., Wilbert, J., Sauer, O. A., Vordermark, D., & Flentje, M. P. (2007) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2007.05.030 · Cited by 80 · cited 2×
“Intracranial position of brain metastases is not altered by changes of peritumoral edema or steroid treatment during an interval of 1 week between planning and treatment [31].”
BackgroundSelf-citationToxicity after Intensity-Modulated, Image-Guided Radiotherapy for Prostate Cancer
Gückenberger, M., Ok, S., Polat, B., Sweeney, R. A., & Flentje, M. P. (2010) · Strahlentherapie und Onkologie · doi:10.1007/s00066-010-2144-z · Cited by 72 · cited 1×
“Clinical Results There is no high-evidence level data that IGRT improves outcome for prostate cancer, but promising retrospective studies reported decreased toxicity when IGRT was added to radiotherapy [9, 14] and multiple studies reported low toxicity rates when IGRT/IMRT were practiced in dose escalation [35].”
BackgroundSelf-citationBohrer, M., Schröder, P., Welzel, G., Wertz, H., Lohr, F., Wenz, F. K., & Mai, S. K. (2008) · Strahlentherapie und Onkologie · doi:10.1007/s00066-008-1837-z · Cited by 42
Self-citation
Cited by
TIGRE: a MATLAB-GPU toolbox for CBCT image reconstruction
Biguri, A., Dosanjh, M., Hancock, S., & Soleimani, M. (2016) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/2/5/055010 · Cited by 370
Deep Inspiration Breath Hold—Based Radiation Therapy: A Clinical Review
Boda-Heggemann, J., Knopf, A.-C., Simeonova-Chergou, A., Wertz, H., Stieler, F., Jahnke, A., Jahnke, L., Fleckenstein, J., Vogel, L., Arns, A., et al. (2016) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2015.11.049 · Cited by 247
Self-citationReview and Uses of Stereotactic Body Radiation Therapy for Oligometastases
Alongi, F., Arcangeli, S., Filippi, A. R., Ricardi, U., & Scorsetti, M. (2012) · The Oncologist · doi:10.1634/theoncologist.2012-0092 · Cited by 209
Synthetic CT generation from CBCT images via deep learning
Chen, L., Liang, X., Shen, C., Jiang, S., & Wang, J. (2020) · Medical Physics · doi:10.1002/mp.13978 · Cited by 201
“Image-guided radiation therapy , which uses frequent imaging during a course of radiation therapy, has been widely used to improve precision and accuracy of radiation treatment delivery 1,2 .”
MethodDeep learning based synthetic‐CT generation in radiotherapy and PET: A review
Spadea, M. F., Maspero, M., Zaffino, P., & Seco, J. (2021) · Medical Physics · doi:10.1002/mp.15150 · Cited by 201
Metadata
- Authors
- Boda-Heggemann, J., Lohr, F., Wenz, F., Flentje, M., & Guckenberger, M.
- Venue
- Strahlentherapie und Onkologie
- Published
- 2011-04-26
- Volume
- 187
- Issue
- 5
- Pages
- 284-291
- ISSN
- 0179-7158 (ISSN-L)
- 1439-099X
- OpenAlex
- W166308433
- Cited by
- 211
- References
- 32
- FWCI
- 22.88
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.