CoChat

Transkutane, submentale Elektrostimulationstherapie bei obstruktiver Schlafapnoe

Verse, T., Schwalb, J., Hörmann, K., Stuck, B. A., Maurer, J. T. · 2003 · HNO

The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.

Abstract

Background Transcutaneous electrical stimulation while asleep has been used to treat obstructive sleep apnea (OSA), although without convincing results. Modern strategies consist of electrical muscle training for a number of weeks during wakefulness rather than stimulation during sleep. Objective The purpose of this study was to assess the practicability, safety, and efficacy of a new device, SilentOne (Imperpuls, Chemnitz, Germany). Patients and methods Fifteen patients with various degrees of OSA used transcutaneous submental electrical stimulation therapy for 4-5 weeks every day, day and night. A patient's diary recorded practicability and potential adverse events. Respiratory parameters were recorded by fully attended polysomnography in the sleep lab. Daytime sleepiness and snoring were assessed by questionnaires. Results The apnea-hypopnea-index decreased from 29.2 before to 21.2 after therapy (P<0.05). Daytime sleepiness improved significantly (P<0.01) as did snoring (P<0.005). CONCLUSIONS. Transcutaneous electrical stimulation therapy using SilentOne proved to be safe, easy to use, and potent. However, therapy showed a limited cure rate.

Overview

Integrity signals

Registry

Crossref · 10.1007/s00106-003-0842-x

Cites

27 of 27 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 27 references

Research works printed but not linked: 1

  1. Penzel T, Brandenburg U (1996) Diagnostische Verfahren und Standards in der Schlafmedizin. Internist 37: 442–453

Cited by

See all 31

Metadata

Authors
Verse, T., Schwalb, J., Hörmann, K., Stuck, B. A., & Maurer, J. T.
Affiliations
Universitäts HNO Klinik Mannheim (DE)
Corresponding author
Verse, T.
Venue
HNO
Published
2003-06-18
Volume
51
Issue
12
Pages
966-970
ISSN
  • 0017-6192 (ISSN-L)
  • 1433-0458
OpenAlex
W2090750014
Cited by
31
References
26
Citations by year
2024: 1 · 2022: 1 · 2021: 2 · 2020: 2 · 2019: 2 · 2018: 3 · 2017: 1 · 2016: 2 · 2014: 1 · 2012: 1
FWCI
1.53
Type
journal article
Language
de
Open access
closed
Licence
www.springer.com/tdm (tdm)
Locations
  • HNO (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Physiology (medical) › Obstructive Sleep Apnea Research
  • Health Sciences › Dentistry › Oral Surgery › Temporomandibular Joint Disorders
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Respiratory Support and Mechanisms
Keywords
obstructive sleep apnea, transcutaneous electrical stimulation, apnea-hypopnea index, daytime sleepiness, snoring, device safety and efficacy
MeSH terms
Adult, Aged, Airway Resistance, Circadian Rhythm, Transcutaneous Electric Nerve Stimulation, Equipment Design, Female, Humans, Male, Middle Aged, Mouth Floor, Muscle Tonus, Tongue, Wakefulness, Treatment Outcome, Polysomnography, Sleep Apnea, Obstructive

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Transkutane, submentale Elektrostimulationstherapie bei obstruktiver Schlafapnoe. https://app.cochat.ai/papers/10.1007/s00106-003-0842-x
The paper
Verse, T., Schwalb, J., Hörmann, K., Stuck, B. A., & Maurer, J. T. (2003). Transkutane, submentale Elektrostimulationstherapie bei obstruktiver Schlafapnoe. HNO. https://doi.org/10.1007/s00106-003-0842-x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.