Abstract

With randomised trial data confirming that continuous glucose monitoring (CGM) is associated with improvements in maternal glucose control and neonatal health outcomes, CGM is increasingly used in antenatal care. Across pregnancy, the ambition is to increase the CGM time in range (TIR), while reducing time above range (TAR), time below range (TBR) and glycaemic variability measures. Pregnant women with type 1 diabetes currently spend, on average, 50% (12 h), 55% (13 h) and 60% (14 h) in the target range of 3.5-7.8 mmol/l (63-140 mg/dl) during the first, second and third trimesters, respectively. Hyperglycaemia, as measured by TAR, reduces from 40% (10 h) to 33% (8 h) during the first to third trimester. A TIR of >70% (16 h, 48 min) and a TAR of <25% (6 h) is achieved only in the final weeks of pregnancy. CGM TBR data are particularly sensor dependent, but regardless of the threshold used for individual patients, spending ≥4% of time (1 h) below 3.5 mmol/l or ≥1% of time (15 min) below 3.0 mmol/l is not recommended. While maternal hyperglycaemia is a well-established risk factor for obstetric and neonatal complications, CGM-based risk factors are emerging. A 5% lower TIR and 5% higher TAR during the second and third trimesters is associated with increased risk of large for gestational age infants, neonatal hypoglycaemia and neonatal intensive care unit admissions. For optimal neonatal outcomes, women and clinicians should aim for a TIR of >70% (16 h, 48 min) and a TAR of <25% (6 h), from as early as possible during pregnancy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s00125-019-4904-3

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 14 references

Cited by

See all 137

Metadata

Authors
Murphy, H. R.
Venue
Diabetologia
Published
2019-06-03
Volume
62
Issue
7
Pages
1123-1128
ISSN
  • 0012-186X (ISSN-L)
  • 1432-0428
OpenAlex
W2948847239
Cited by
137
References
14
FWCI
9.46
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Continuous glucose monitoring targets in type 1 diabetes pregnancy: every 5% time in range matters. https://app.cochat.ai/papers/10.1007/s00125-019-4904-3
The paper
Murphy, H. R. (2019). Continuous glucose monitoring targets in type 1 diabetes pregnancy: every 5% time in range matters. Diabetologia. https://doi.org/10.1007/s00125-019-4904-3

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.