Arterial oxygen tension and mortality in mechanically ventilated patients
The DOI matches its Crossref record.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
BTS guideline for oxygen use in adults in healthcare and emergency settings
O'Driscoll, B. R., Howard, L. S., Earis, J., & Mak, V (2017) · Thorax · doi:10.1136/thoraxjnl-2016-209729 · Cited by 679
Arterial hyperoxia and mortality in critically ill patients: a systematic review and meta-analysis
Damiani, E., Adrario, E., Girardis, M., Romano, R., Pelaia, P., Singer, M., & Donati, A. (2014) · Critical Care · doi:10.1186/s13054-014-0711-x · Cited by 308
Helmerhorst, H. J. F., Roos-Blom, M.-J., van Westerloo, D. J., & de Jonge, E. (2015) · Critical Care Medicine · doi:10.1097/ccm.0000000000000998 · Cited by 303
Asfar, P., Schortgen, F., Boisramé-Helms, J., Charpentier, J., Guérot, E., Megarbane, B., Grimaldi, D., Grelon, F., Anguel, N., Lasocki, S., et al. (2017) · The Lancet Respiratory Medicine · doi:10.1016/s2213-2600(17)30046-2 · Cited by 303
Metrics of Arterial Hyperoxia and Associated Outcomes in Critical Care*
Helmerhorst, H. J. F., Arts, D. L., Schultz, M. J., van der Voort, P. H. J., Abu-Hanna, A., de Jonge, E., & van Westerloo, D. J. (2017) · Critical Care Medicine · doi:10.1097/ccm.0000000000002084 · Cited by 205
Hafner, S., Beloncle, F., Koch, A., Radermacher, P., & Asfar, P. (2015) · Annals of Intensive Care · doi:10.1186/s13613-015-0084-6 · Cited by 201
“A more recent study of unadjusted odds ratios for PaO2 deciles in 152,680 patients confirmed the impact of hypoxemia, whereas hyperoxemia even >40 kPa (300 mmHg) had no impact on outcome [165].”
BackgroundBench-to-bedside review: the effects of hyperoxia during critical illness
Helmerhorst, H. J. F., Schultz, M. J., van der Voort, P. H. J., de Jonge, E., & van Westerloo, D. J. (2015) · Critical Care · doi:10.1186/s13054-015-0996-4 · Cited by 187
“[57] (2012) Australia and New Zealand Cohort 2000–2009 MV 152,680 – Hypoxia in first 24 h of admission was associated with increased in-hospital mortality, but hyperoxia was not.”
BackgroundJanz, D. R., Hollenbeck, R. D., Pollock, J. S., McPherson, J. A., & Rice, T. W. (2012) · Critical Care Medicine · doi:10.1097/ccm.0b013e3182656976 · Cited by 180
“Our results differ from a recent, large cohort study that found the association between hyperoxia and worse mortality was lost in multivariable analysis when severity of illness was included in the regression model (27).”
Result
Metadata
- Authors
- Eastwood, G., Bellomo, R., Bailey, M., Taori, G., Pilcher, D., Young, P., & Beasley, R.
- Venue
- Intensive Care Medicine
- Published
- 2011-11-30
- Volume
- 38
- Issue
- 1
- Pages
- 91-98
- ISSN
- 0342-4642 (ISSN-L)
- 1432-1238
- OpenAlex
- W2003049295
- Cited by
- 195
- References
- 0
- FWCI
- 8.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.