Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 482

The DOI matches its Crossref record; 47 of the 47 references it cites were found in a registry or an index.

Passive leg raising for predicting fluid responsiveness: a systematic review and meta-analysis

Monnet, Xavier, Marik, Paul, Teboul, Jean-Louis·2016·Intensive Care Medicine

Abstract

PurposeWe performed a systematic review and meta-analysis of studies investigating the passive leg raising (PLR)-induced changes in cardiac output (CO) and in arterial pulse pressure (PP) as predictors of fluid responsiveness in adults.MethodsMEDLINE, EMBASE and Cochrane Database were screened for relevant original and review articles. The meta-analysis determined the pooled area under the ROC curve, the sensitivity, specificity and threshold for the PLR test when assessed with CO and PP.ResultsTwenty-one studies (991 adult patients, 995 fluid challenges) were included. CO was measured by echocardiography in six studies, calibrated pulse contour analysis in six studies, bioreactance in four studies, oesophageal Doppler in three studies, transpulmonary thermodilution or pulmonary artery catheter in one study and suprasternal Doppler in one study. The pooled correlation between the PLR-induced and the fluid-induced changes in CO was 0.76 (0.73–0.80). For the PLR-induced changes in CO, the pooled sensitivity was 0.85 (0.81–0.88) and the pooled specificity was 0.91 (0.88–0.93). The area under the ROC curve was 0.95 ± 0.01. The best threshold was a PLR-induced increase in CO ≥10 ± 2 %. For the PLR-induced changes in PP (8 studies, 432 fluid challenges), the pooled sensitivity was 0.56 (0.49–0.53), the pooled specificity was 0.83 (0.77–0.88) and the pooled area under the ROC curve was 0.77 ± 0.05. Sensitivity and subgroup analysis were consistent with the primary analysis.ConclusionsPLR-induced changes in CO very reliably predict the response of CO to volume expansion in adults with acute circulatory failure. When PLR effects are assessed by changes in PP, the specificity of the PLR test remains acceptable but its sensitivity is poor.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s00134-015-4134-1

Cites

47 of 47 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 47 references

Cited by

See all 482

Metadata

Authors
Monnet, X., Marik, P., & Teboul, J.-L.
Venue
Intensive Care Medicine
Published
2016-01-29
Volume
42
Issue
12
Pages
1935-1947
ISSN
  • 0342-4642 (ISSN-L)
  • 1432-1238
OpenAlex
W2260276881
Cited by
482
References
47
FWCI
9.40
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Passive leg raising for predicting fluid responsiveness: a systematic review and meta-analysis. https://app.cochat.ai/papers/10.1007/s00134-015-4134-1
The paper
Monnet, X., Marik, P., & Teboul, J.-L. (2016). Passive leg raising for predicting fluid responsiveness: a systematic review and meta-analysis. Intensive Care Medicine. https://doi.org/10.1007/s00134-015-4134-1

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.