Comparative study of lung ultrasound and chest computed tomography scan in the assessment of severity of confirmed COVID-19 pneumonia
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The relationship between lung ultrasound (LUS) and chest computed tomography (CT) scans in patients with severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) pneumonia is not clearly defined. The primary objective of our study was to assess the performance of LUS in determining severity of SARS-CoV-2 pneumonia compared with chest CT scan. Secondary objectives were to test the association between LUS score and location of the patient, use of mechanical ventilation, and the pulse oximetry (SpO 2 )/fractional inspired oxygen (FiO 2 ) ratio. A multicentre observational study was performed between 15 March and 20 April 2020. Patients in the Emergency Department (ED) or Intensive Care Unit (ICU) with acute dyspnoea who were PCR positive for SARS-CoV-2, and who had LUS and chest CT performed within a 24-h period, were included. One hundred patients were included. LUS score was significantly associated with pneumonia severity assessed by chest CT and clinical features. The AUC of the ROC curve of the relationship of LUS versus chest CT for the assessment of severe SARS-CoV-2 pneumonia was 0.78 (CI 95% 0.68–0.87; p < 0.0001). A high LUS score was associated with the use of mechanical ventilation, and with a SpO 2 /FiO 2 ratio below 357. In known SARS-CoV-2 pneumonia patients, the LUS score was predictive of pneumonia severity as assessed by a chest CT scan and clinical features. Within the limitations inherent to our study design, LUS can be used to assess SARS-CoV-2 pneumonia severity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
High-Flow Oxygen through Nasal Cannula in Acute Hypoxemic Respiratory Failure
Frat, J.-P., Thille, A. W., Mercat, A., Girault, C., Ragot, S., Perbet, S., Prat, G., Boulain, T., Morawiec, E., Cottereau, A., et al. (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1503326 · Cited by 2,342
Cited by
Kuroda, Y., Kaneko, T., Yoshikawa, H., Uchiyama, S., Nagata, Y., Matsushita, Y., Hiki, M., Minamino, T., Takahashi, K., Daida, H., et al. (2023) · PLOS ONE · doi:10.1371/journal.pone.0281127 · Cited by 36
Metadata
- Authors
- Zieleskiewicz, L., Markarian, T., Lopez, A., Taguet, C., Mohammedi, N., Boucekine, M., Baumstarck, K., Besch, G., Mathon, G., Duclos, G., Bouvet, L., Michelet, P., Allaouchiche, B., Chaumoître, K., Di Bisceglie, M., Leone, M., & on behalf of the AZUREA Network
- Venue
- Intensive Care Medicine
- Published
- 2020-07-29
- Volume
- 46
- Issue
- 9
- Pages
- 1707-1713
- ISSN
- 0342-4642 (ISSN-L)
- 1432-1238
- OpenAlex
- W3046009847
- Cited by
- 180
- References
- 1
- FWCI
- 20.24
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparative study of lung ultrasound and chest computed tomography scan in the assessment of severity of confirmed COVID-19 pneumonia. https://app.cochat.ai/papers/10.1007/s00134-020-06186-0
- The paper
- Zieleskiewicz, L., Markarian, T., Lopez, A., Taguet, C., Mohammedi, N., Boucekine, M., Baumstarck, K., Besch, G., Mathon, G., Duclos, G., Bouvet, L., Michelet, P., Allaouchiche, B., Chaumoître, K., Di Bisceglie, M., Leone, M., & on behalf of the AZUREA Network. (2020). Comparative study of lung ultrasound and chest computed tomography scan in the assessment of severity of confirmed COVID-19 pneumonia. Intensive Care Medicine. https://doi.org/10.1007/s00134-020-06186-0
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.