The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Extravascular lung water and intrathoracic blood volume: double versus single indicator dilution technique
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
On the Theory of the Indicator-Dilution Method for Measurement of Blood Flow and Volume
Meier, P., & Zierler, K. L. (1954) · Journal of Applied Physiology · doi:10.1152/jappl.1954.6.12.731 · Cited by 1,274
A Prospective Study of Lung Water Measurements during Patient Management in an Intensive Care Unit
Eisenberg, P. R., Hansbrough, J. R., Anderson, D., & Schuster, D. P. (1987) · American Review of Respiratory Disease · doi:10.1164/ajrccm/136.3.662 · Cited by 197
Cited by
Assessment of cardiac preload and extravascular lung water by single transpulmonary thermodilution
Sakka, S. G., Rühl, C. C., Pfeiffer, U. J., Beale, R., McLuckie, A., Reinhart, K., & Meier-Hellmann, A. (2000) · Intensive Care Medicine · doi:10.1007/s001340050043 · Cited by 920
Global End-Diastolic Volume as an Indicator of Cardiac Preload in Patients With Septic Shock *
Michard, F., Alaya, S., Zarka, V., Bahloul, M., Richard, C., & Teboul, J.-L. (2003) · Chest · doi:10.1378/chest.124.5.1900 · Cited by 352
Metadata
- Authors
- Neumann, P.
- Venue
- Intensive Care Medicine
- Published
- 1999-02-17
- Volume
- 25
- Issue
- 2
- Pages
- 216-219
- ISSN
- 0342-4642 (ISSN-L)
- 1432-1238
- OpenAlex
- W1987153927
- Cited by
- 285
- References
- 3
- FWCI
- 3.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Extravascular lung water and intrathoracic blood volume: double versus single indicator dilution technique. https://app.cochat.ai/papers/10.1007/s001340050819
- The paper
- Neumann, P. (1999). Extravascular lung water and intrathoracic blood volume: double versus single indicator dilution technique. Intensive Care Medicine. https://doi.org/10.1007/s001340050819
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.