Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 217

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Evaluation of lower leg function in patients with Achilles tendinopathy

Silbernagel, Karin Grävare, Gustavsson, Alexander, Thomeé, Roland, Karlsson, Jon·2006·Knee Surgery, Sports Traumatology, Arthroscopy

Abstract

Achilles tendinopathy is considered to be one of the most common overuse injuries in elite and recreational athletes. However, the effect that the Achilles tendinopathy has on patients’ physical performance is still unclear. The purpose of this study was to evaluate if Achilles tendinopathy caused functional deficits on the injured side compared with the non‐injured side in patients. A test battery comprised of tests for different aspects of muscle‐tendon function of the gastrocnemius, soleus and Achilles tendon complex was developed to evaluate lower leg function. The test battery's test–retest reliability and sensitivity (the percent probability that the tests would demonstrate abnormal lower limb symmetry index in patients) were also evaluated. The test battery consisted of three jump tests, a counter movements jump (CMJ), a drop counter movement jump (drop CMJ) and hopping, and two strength tests, concentric toe‐raises, eccentric–concentric toe‐raises and toe‐raises for endurance. The reliability was evaluated through a test–retest design on 15 healthy subjects. The test battery's sensitivity and possible functional deficits in patients with Achilles tendinopathy were evaluated on 42 patients (19 women and 23 men). An excellent reliability was found between test days 1–2 and 2–3 for all tests (ICC = 0.76–0.94) except for concentric toe‐raise, test 2–3, which had fair reliability (ICC = 0.73). The methodological error ranged from 8 to 17%. There were significant differences (P = 0.001–0.049) between the non‐injured (or least symptomatic) side and injured (most symptomatic) side for hopping, drop CMJ, concentric and eccentric–concentric toe‐raises, and significant differences (P = 0.000–0.012) in the level of pain during CMJ, hopping, and drop CMJ. The sensitivity of the test battery at a 90% capacity was 88. Achilles tendinopathy causes not only pain and symptoms in patients but also apparent impairments in various aspects of lower leg muscle‐tendon function as measured with the test battery. This test battery is reliable and able to detect differences in lower leg function between the injured or “most symptomatic” and non‐injured or “least symptomatic” side in patients with Achilles tendinopathy. The test battery has higher demand on patients’ function compared with each individual test.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s00167-006-0150-6

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 217

Metadata

Authors
Silbernagel, K. G., Gustavsson, A., Thomeé, R., & Karlsson, J.
Venue
Knee Surgery, Sports Traumatology, Arthroscopy
Publisher
Wiley
Published
2006-07-21
Volume
14
Issue
11
Pages
1207-1217
ISSN
  • 0942-2056 (ISSN-L)
  • 1433-7347
OpenAlex
W2000136395
Cited by
217
References
2
FWCI
2.77
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evaluation of lower leg function in patients with Achilles tendinopathy. https://app.cochat.ai/papers/10.1007/s00167-006-0150-6
The paper
Silbernagel, K. G., Gustavsson, A., Thomeé, R., & Karlsson, J. (2006). Evaluation of lower leg function in patients with Achilles tendinopathy. Knee Surgery, Sports Traumatology, Arthroscopy. https://doi.org/10.1007/s00167-006-0150-6

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.