Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 233

The DOI matches its Crossref record.

Factors predicting hamstring tendon autograft diameters and resulting failure rates after anterior cruciate ligament reconstruction

Park, Soo Yeon, Oh, Hoon, Park, Sua, Lee, Jung Hwan, Lee, Sang Hak, Yoon, Kyoung Ho · 2013 · Knee Surgery, Sports Traumatology, Arthroscopy

Abstract

Purpose: The purposes of this study are to confirm factors that affect the diameter of hamstring tendon autograft and to compare failure rates between the factors after anterior cruciate ligament (ACL) reconstruction. Methods: A total of 296 patients that underwent reconstruction using hamstring tendon autograft at our clinics for ACL injury between September 2005 and June 2008 were enrolled for this study. The diameters of gracilis and semitendinosus tendons (harvested from the affected knee) and four‐strand graft tendon made by folding the gracilis and semitendinosus tendons in two layers were measured. Before operating, we recorded the age, height, weight, Body Mass Index (BMI), gender and athlete versus non‐athlete identity of the subjects and checked their correlations with graft diameters. Patients that recorded a grade C or D on the International Knee Documentation Committee Knee Examination Form, as well as patients that underwent revision, were defined as failures and analysed by related factors. Results: The mean diameter was 1.5 mm ± 0.2 for gracilis tendon, 2.2 mm ± 0.3 for semitendinosus tendon and 7.2 mm ± 0.7 for graft tendon. Except for age, factors including height, weight, BMI, gender and athlete versus non‐athlete identity were found to be significantly related to graft diameter. Correlation was strongest with height (p < 0.001). With respect to failure rates after ACL reconstruction, patients with a graft diameter of 8.0 mm or more demonstrated statistically better results than patients with a diameter of below 8.0 mm (p = 0.043). However, failure rates did not differ significantly with respect to other factors. Conclusions: The diameter of hamstring tendon autograft may be different depending on height, weight, BMI and gender of the patient, as well as whether or not the patient is an athlete. Although we did not find statistically significant differences in failure rates after ACL reconstruction, this study demonstrated relatively better results in patients with a graft diameter of 8.0 mm or more. Level of evidence: Case series, Level IV.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s00167-012-2085-4

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 233

Metadata

Authors
Park, S. Y., Oh, H., Park, S., Lee, J. H., Lee, S. H., & Yoon, K. H.
Venue
Knee Surgery, Sports Traumatology, Arthroscopy
Publisher
Wiley
Published
2012-06-12
Volume
21
Issue
5
Pages
1111-1118
ISSN
  • 0942-2056 (ISSN-L)
  • 1433-7347
OpenAlex
W2020835499
Cited by
233
References
0
FWCI
8.12
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Factors predicting hamstring tendon autograft diameters and resulting failure rates after anterior cruciate ligament reconstruction. https://app.cochat.ai/papers/10.1007/s00167-012-2085-4
The paper
Park, S. Y., Oh, H., Park, S., Lee, J. H., Lee, S. H., & Yoon, K. H. (2013). Factors predicting hamstring tendon autograft diameters and resulting failure rates after anterior cruciate ligament reconstruction. Knee Surgery, Sports Traumatology, Arthroscopy. https://doi.org/10.1007/s00167-012-2085-4

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.