The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
The minimal clinically important difference for Knee Society Clinical Rating System after total knee arthroplasty for primary osteoarthritis
Abstract
PURPOSE: The Knee Society Clinical Rating System (KS) is one of the most popular tools used to assess patient outcome after total knee arthroplasty (TKA), but its minimal clinically important difference (MCID) has not been identified. This study aims to identify the MCID of KS function score (KS-FS) and knee score (KS-KS) after TKA in patients with primary knee osteoarthritis. METHODS: The authors retrospectively analysed patients who underwent TKA for primary knee osteoarthritis between 2005 and 2015 in a single institution. KS-FS, KS-KS, and Oxford Knee Score (OKS) were collected pre-operatively and 2 years post-operatively. Patient satisfaction with TKA at 2 years was also collected. Anchor-based approach with 2 external indicators was used. The MCID for KS-FS and KS-KS was determined using simple linear regression according to patient satisfaction with TKA and the MCID of OKS. RESULTS: The mean age of the 550 subjects studied was 66 ± 8 years. There were 373 (67.8 %) female subjects. The KS-FS improved by 22.8 (95 % CI 20.9-24.6) points, and the KS-KS improved by 44.4 (95 % CI 42.6-46.3) points. The MCID identified for KS-FS is between 6.1 (95 % CI 5.1-7.1) and 6.4 (95 % CI 4.4-8.4) and between 5.3 (95 % CI 4.3-6.3) and 5.9 (95 % CI 3.9-7.8) for KS-KS. CONCLUSIONS: This is the first study, to the knowledge of the authors, to identify the MCID of KS. This will allow future trials to have an accurate prediction of sample size. Clinically, physicians will be able to better interpret outcomes of TKA studies to guide a treatment option. LEVEL OF EVIDENCE: IV.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
WARE, J. E., KOSINSKI, M., & KELLER, S. D. (1996) · Medical Care · doi:10.1097/00005650-199603000-00003 · Cited by 17,392 · cited 3×
“Compared to PROM such as WOMAC and SF-36, KS has the advantage of measuring the range of motion and alignment.”
MethodTerwee, C. B., Mokkink, L. B., Knol, D. L., Ostelo, R. W. J. G., Bouter, L. M., & de Vet, H. C. W. (2012) · Quality of Life Research · doi:10.1007/s11136-011-9960-1 · Cited by 1,978
The truly remarkable universality of half a standard deviation: confirmation through another look
Norman, G. R., Sloan, J. A., & Wyrwich, K. W. (2004) · Expert Review of Pharmacoeconomics & Outcomes Research · doi:10.1586/14737167.4.5.581 · Cited by 490 · cited 2×
“The estimated MCID of KS based on suggestion by Norman et al [21] is 9 ± 23 [18].”
MethodResult
Cited by
Harris, J. D., Brand, J. C., Cote, M. P., Faucett, S. C., & Dhawan, A. (2017) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1016/j.arthro.2017.01.053 · Cited by 498
Metadata
- Authors
- Lee, W. C., Kwan, Y. H., Chong, H. C., & Yeo, S. J.
- Venue
- Knee Surgery, Sports Traumatology, Arthroscopy
- Publisher
- Wiley
- Published
- 2016-06-21
- Volume
- 25
- Issue
- 11
- Pages
- 3354-3359
- ISSN
- 0942-2056 (ISSN-L)
- 1433-7347
- OpenAlex
- W2472875983
- Cited by
- 241
- References
- 3
- FWCI
- 20.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The minimal clinically important difference for Knee Society Clinical Rating System after total knee arthroplasty for primary osteoarthritis. https://app.cochat.ai/papers/10.1007/s00167-016-4208-9
- The paper
- Lee, W. C., Kwan, Y. H., Chong, H. C., & Yeo, S. J. (2017). The minimal clinically important difference for Knee Society Clinical Rating System after total knee arthroplasty for primary osteoarthritis. Knee Surgery, Sports Traumatology, Arthroscopy. https://doi.org/10.1007/s00167-016-4208-9
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.