Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 163

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Arthroscopic intra‐ and extra‐articular anterior cruciate ligament reconstruction with gracilis and semitendinosus tendons

Marcacci, M., Zaffagnini, S., Iacono, F., Neri, M. P., Loreti, I., Petitto, A. · 1998 · Knee Surgery, Sports Traumatology, Arthroscopy

Abstract

Numerous surgical procedures have been developed and used for anterior cruciate ligament (ACL) reconstruction. Patellar tendon is probably the most common graft used, but gracilis and semitendinous tendons present some interesting advantages: small incision, large graft when doubled, characteristics close to ACL, rapid harvest. We describe a combined intra‐ and extra‐articular arthroscopic ACL reconstruction using hamstring tendons which includes some original steps. The tendons are harvested, leaving the distal insertion intact, and sutured together. After drilling of the tibial tunnel, an over‐the‐top arrangement is formed, creating a groove in the posterolateral aspect of the femur. The tendons are then fixed with double staples in the groove, and their remaining part is fixed distally to Gerdy’s tubercle passing under the fascia, but over the lateral collateral ligament (LCL). This technique ensures sufficient strength in the graft and permits correction of any associated instability, because of the presence of the extra‐articular portion of the tendons. Furthermore, the over‐the‐top arrangement reduces trauma and possible pitfalls related to tunnel construction and permits isometry of the extra‐articular portion to be established. Forty patients involved in sports activity were prospectively selected and evaluated at a minimum 2 years’ follow‐up. IKDC score and Lysholm score were used for clinical evaluation, and the KT‐2000 was used for instrumental laxity measurements. Resumption of sport and time to that point were recorded as well as Tegner activity score. We had 92.5% normal and fairly normal knees according to IKDC score and only 7.5% abnormal knees. Mean Lysholm score was 95. Mean Tegner score was 7.2. KT‐2000 showed a mean injured/uninjured difference of 2.1 mm. In all, 90% of patients resumed sports at the same level, 67.5% in 3–4 months and 27.5% in 4–6 months. The highly satisfactory results of this series with no major complications confirm the reliability of this techinque and the possibility of guaranteeing functional behaviour in the knee.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s001670050075

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Marcacci, M., Zaffagnini, S., Iacono, F., Neri, M. P., Loreti, I., & Petitto, A.
Venue
Knee Surgery, Sports Traumatology, Arthroscopy
Publisher
Wiley
Published
1998-04
Volume
6
Issue
2
Pages
68-75
ISSN
  • 0942-2056 (ISSN-L)
  • 1433-7347
OpenAlex
W2006741869
Cited by
163
References
1
FWCI
1.11
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.