Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 194

The DOI matches its Crossref record.

Hamstring graft motion in the femoral bone tunnel when using titanium button/ polyester tape fixation

Höher, Jürgen, Livesay, Glen A., Ma, C. Benjamin, Withrow, John D., Fu, Freddie H., Woo, Savio L‐Y. · 1999 · Knee Surgery, Sports Traumatology, Arthroscopy

Abstract

The objective of this study was to determine the relative motion of a quadruple hamstring graft within the femoral bone tunnel (graft‐tunnel motion) under tensile loading. Six graft constructs were prepared from the semitendinosus and gracilis tendons of human cadavers and were fixed with a titanium button and polyester tape within a bone tunnel in a cadaveric femur. Three different lengths of polyester tape (15, 25, and 35 mm loops) were evaluated. The femur was held stationary and uniaxial tensile loads were applied to the distal end of the graft using a materials testing machine. Each construct was subjected to loading for ten cycles with upper limits of 50 N, 100 N, 200 N and 300 N. Graft‐tunnel motion was then determined using the distances between reflective tape markers placed on the hamstring graft and at the entrance to the femoral bone tunnel, which were tracked with a high‐resolution video system. Graft‐tunnel motion was found to range from 0.7 ± 0.2 mm to 3.3 ± 0.2 mm, and significant increases in graft‐tunnel motion were observed with increasing tensile loads (P < 0.05). Shorter tape length (15 mm) resulted in significantly less motion when compared to longer tape length (35 mm) (P < 0.05). We conclude that graft‐tunnel motion is significant and should be considered when using this fixation technique. Early stress on the graft, as seen in postoperative rehabilitation exercises and athletic activities, may cause large graft‐tunnel motion before graft incorporation is complete. A shorter distance between the tendon tissue and the titanium button is recommended to minimize the amount of graft‐tunnel motion. Alternative fixation materials to polyester tape, or different fixation techniques, need to be developed such that graft‐tunnel motion can be reduced. Further studies are needed to evaluate the effect of graft‐tunnel motion on graft incorporation in the bone tunnel.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s001670050151

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 194

Metadata

Authors
Höher, J., Livesay, G. A., Ma, C. B., Withrow, J. D., Fu, F. H., & Woo, S. L.
Venue
Knee Surgery, Sports Traumatology, Arthroscopy
Publisher
Wiley
Published
1999-07
Volume
7
Issue
4
Pages
215-219
ISSN
  • 0942-2056 (ISSN-L)
  • 1433-7347
OpenAlex
W2043579297
Cited by
194
References
0
FWCI
5.51
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Hamstring graft motion in the femoral bone tunnel when using titanium button/ polyester tape fixation. https://app.cochat.ai/papers/10.1007/s001670050151
The paper
Höher, J., Livesay, G. A., Ma, C. B., Withrow, J. D., Fu, F. H., & Woo, S. L. (1999). Hamstring graft motion in the femoral bone tunnel when using titanium button/ polyester tape fixation. Knee Surgery, Sports Traumatology, Arthroscopy. https://doi.org/10.1007/s001670050151

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.