The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Assessing the biocompatibility of NiTi shape memory alloys used for medical applications
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wayman, C. M., & 大塚, 和. (1998) · Cambridge University Press eBooks · Cited by 3,134
Nickel essentiality, toxicity, and carcinogenicity
Denkhaus, E., & Salnikow, K. (2002) · Critical Reviews in Oncology/Hematology · doi:10.1016/s1040-8428(01)00214-1 · Cited by 1,129
Saburi, T. (2000) · Materials Science Forum · doi:10.4028/b-buy1cx · Cited by 914
Electrochemical and surface characterization of a nickel–titanium alloy
Wever, D. J., Veldhuizen, A. G., de Vries, J., Busscher, H. J., Uges, D. R. A., & van Horn, J. R. (1998) · Biomaterials · doi:10.1016/s0142-9612(97)00210-x · Cited by 439
Ryh�nen, J., Niemi, E., Serlo, W. S., Niemel�, E., Sandvik, P., Pernu, H., & Salo, T. (1997) · Journal of Biomedical Materials Research · Cited by 364
Nielsen, N. H., & Menné, T. (1992) · Acta Dermato-Venereologica · doi:10.2340/0001555572456460 · Cited by 310
Kujala, S., Ryhänen, J., Danilov, A., & Tuukkanen, J. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00359-4 · Cited by 284
Corrosion resistance tests on NiTi shape memory alloy
Rondelli, G. (1996) · Biomaterials · doi:10.1016/0142-9612(95)00352-5 · Cited by 266
In vivo study on metal release from fixed orthodontic appliances and DNA damage in oral mucosa cells
Faccioni, F., Franceschetti, P., Cerpelloni, M., & Fracasso, M. E. (2003) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/j.ajodo.2003.09.010 · Cited by 250
Barceloux, D. G., & Barceloux, D. (1999) · Journal of Toxicology: Clinical Toxicology · doi:10.1081/clt-100102423 · Cited by 248
Cap43, a novel gene specifically induced by Ni2+ compounds.
Zhou, D., Salnikow, K., & Costa, M. (1998) · PubMed · Cited by 224
Nickel allergy in adolescents in relation to orthodontic treatment and piercing of ears
Kerosuo, H., Kullaa, A., Kerosuo, E., Kanerva, L., & Hensten-Pettersen, A. (1996) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/s0889-5406(96)70175-0 · Cited by 220
Nickel hypersensitivity in the orthodontic patient
Bass, J. K., Fine, H. A., & Cisneros, G. J. (1993) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/0889-5406(93)70009-d · Cited by 217
Ryh�nen, J., Kallioinen, M., Tuukkanen, J., Junila, J., Niemel�, E., Sandvik, P., & Serlo, W. (1998) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(19980905)41:3<481::aid-jbm19>3.0.co;2-l · Cited by 191
Corrosion and wear-corrosion behavior of NiTi modified by plasma source ion implantation
Tan, L. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00271-0 · Cited by 182
Biodegradation of orthodontic appliances. Part II. Changes in the blood level of nickel
Bishara, S. E., Barrett, R. D., & Selim, M. I. (1993) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/s0889-5406(05)81760-3 · Cited by 163
Kim, H., & Johnson, J. W. (1999) · PubMed · Cited by 161
Bogdanski, D., Köller, M., Müller, D., Muhr, G., Bram, M., Buchkremer, H. P., Stöver, D., Choi, J.-S., & Epple, M. (2002) · Biomaterials · doi:10.1016/s0142-9612(02)00200-4 · Cited by 120
(2003) · doi:10.1093/ortho/30.2.171 · Cited by 117
Electrochemical and cytocompatibility assessment of NiTiNOL memory shape alloy for orthodontic use
Medawar, L. E., Rocher, P., Hornez, J., Traisnel, M., Brème, J., & Hildebrand, H. F. (2002) · Biomolecular Engineering · doi:10.1016/s1389-0344(02)00041-2 · Cited by 79
Templeton, D. M., Sunderman, F. W., & Herber, R. F. M. (1994) · The Science of The Total Environment · doi:10.1016/0048-9697(94)90400-6 · Cited by 78
Sleight, A. W. (1995) · Materials Research Bulletin · doi:10.1016/0025-5408(96)80006-7 · Cited by 66
Nickel carbonyl: toxicity and human health
Shi, Z. (1994) · The Science of The Total Environment · doi:10.1016/0048-9697(94)90406-5 · Cited by 61
Assad, M., Yahia, L., Rivard, C., & Lemieux, N. (1998) · Journal of Biomedical Materials Research · Cited by 50
In vitro investigation into the biological assessment of orthodontic wires
Rose, E. C., Jonas, I. E., & Kappert, H. F. (1998) · Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie · doi:10.1007/bf01321792 · Cited by 48
Cited by
A Review on Biomedical Titanium Alloys: Recent Progress and Prospect
Zhang, L., & Chen, L. (2019) · Advanced Engineering Materials · doi:10.1002/adem.201801215 · Cited by 1,100
Manufacturing and processing of NiTi implants: A review
Elahinia, M. H., Hashemi, M., Tabesh, M., & Bhaduri, S. B. (2012) · Progress in Materials Science · doi:10.1016/j.pmatsci.2011.11.001 · Cited by 1,067
Porous NiTi for bone implants: A review
Bansiddhi, A., Sargeant, T. D., Stupp, S. I., & Dunand, D. C. (2008) · Acta Biomaterialia · doi:10.1016/j.actbio.2008.02.009 · Cited by 572
Neuss, S., Blomenkamp, I., Stainforth, R., Boltersdorf, D., Jansen, M., Butz, N., Perez-Bouza, A., & Knüchel, R. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2008.12.027 · Cited by 151
“Live/dead stainings were performed as previously described [15] and in accordance to guidelines of the International Organization for Standardization (ISO) [25] after short-term (24 h) and long-term (7 d, 14 d, 21 d) culture of cells on the polymer.”
MethodInfluential
Metadata
- Authors
- Es-Souni, M., Es-Souni, M., & Fischer-Brandies, H.
- Venue
- Analytical and Bioanalytical Chemistry
- Published
- 2005-01-20
- Volume
- 381
- Issue
- 3
- Pages
- 557-567
- ISSN
- 1618-2642 (ISSN-L)
- 1618-2650
- OpenAlex
- W2055179247
- Cited by
- 403
- References
- 25
- FWCI
- 3.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.