Lab in a syringe: fully automated dispersive liquid–liquid microextraction with integrated spectrophotometric detection
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
AbstractA new approach for the integration of various analytical steps inside a syringe (Lab in a Syringe) is presented. Fully automated dispersive liquid–liquid microextraction with integrated spectrophotometric detection is carried out in-syringe using a very simple instrumental setup. The lighter-than-water organic droplets released in the extraction step accumulate at the head of the syringe, where two optical fibers are placed on both sides of the syringe, facing each other and enabling the in situ quantification of the extracted compounds. By this, monitoring of the progressively accumulating droplet in the head of the syringe was further possible. In this first report, the developed instrumental setup has been applied to the determination of the dye rhodamine B in water samples and soft drinks. The main parameters influencing the extraction such as the selection of the extractant and disperser solvents, extractant/disperser and organic/water phase ratios, pH of the aqueous phase, extraction flow rates, and extraction time were investigated. Under the selected conditions, rhodamine B was quantified in a working range of 0.023–2 mg L−1 with a limit of detection of 0.007 mg L−1. Good repeatability values of up to 3.2 % (RSD) were obtained for ten consecutive extractions. The enrichment factor for a 1 mg L−1 rhodamine B standard was 23, and up to 51 extractions were accomplished in 1 h. FigureThe dispersive liquid-liquid microextraction technique is fully automated based on in-syringe extraction followed by in-situ spectrophotometric detection
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Determination of organic compounds in water using dispersive liquid–liquid microextraction
Rezaee, M., Assadi, Y., Milani Hosseini, M.-R., Aghaee, E., Ahmadi, F., & Berijani, S. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.03.007 · Cited by 3,402 · cited 1×
“[1] has attracted much attention due to its simplicity and concomitant achievement of high enrichment factors.”
BackgroundEvolution of dispersive liquid–liquid microextraction method
Rezaee, M., Yamini, Y., & Faraji, M. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.11.088 · Cited by 971 · cited 1×
“Many analytical applications based on the DLLME technique have been published within the last 5 years, confirming the high potential of this technique, which has been compiled in several reviews [2–6].”
MethodDadfarnia, S., & Haji Shabani, A. M. (2010) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.11.022 · Cited by 305 · cited 1×
“Many analytical applications based on the DLLME technique have been published within the last 5 years, confirming the high potential of this technique, which has been compiled in several reviews [2–6].”
MethodDispersive liquid-liquid microextraction for determination of organic analytes
Herrera-Herrera, A. V., Asensio-Ramos, M., Hernández-Borges, J., & Rodríguez-Delgado, M. Á. (2010) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2010.03.016 · Cited by 294 · cited 1×
“Many analytical applications based on the DLLME technique have been published within the last 5 years, confirming the high potential of this technique, which has been compiled in several reviews [2–6].”
MethodKocúrová, L., Balogh, I. S., Šandrejová, J., & Andruch, V. (2012) · Microchemical Journal · doi:10.1016/j.microc.2011.12.002 · Cited by 271
Anthemidis, A. N., & Ioannou, K.-I. G. (2009) · Talanta · doi:10.1016/j.talanta.2009.03.005 · Cited by 258 · cited 1×
“DLLME was automated initially using the sequential injection analysis (SIA) technique [10] and applied to the determination of metals by means of flame or electrothermal atomic absorption spectrometry [11–13].”
MethodAutomated on-line dispersive liquid–liquid microextraction based on a sequential injection system
Andruch, V., Acebal, C. C., Škrlíková, J., Sklenářová, H., Solich, P., Balogh, I. S., Billes, F., & Kocúrová, L. (2012) · Microchemical Journal · doi:10.1016/j.microc.2011.09.006 · Cited by 115
Berton, P., Martinis, E. M., & Wuilloud, R. G. (2010) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2009.11.094 · Cited by 88
Cited by
Green aspects, developments and perspectives of liquid phase microextraction techniques
Spietelun, A., Marcinkowski, Ł., de la Guardia, M., & Namieśnik, J. (2014) · Talanta · doi:10.1016/j.talanta.2013.10.050 · Cited by 333
Kanu, A. B. (2021) · Journal of Chromatography A · doi:10.1016/j.chroma.2021.462444 · Cited by 271
Recent advances and trends in miniaturized sample preparation techniques
Soares da Silva Burato, J., Vargas Medina, D. A., de Toffoli, A. L., Vasconcelos Soares Maciel, E., & Mauro Lanças, F. (2020) · Journal of Separation Science · doi:10.1002/jssc.201900776 · Cited by 254
Recent developments in dispersive liquid–liquid microextraction
Saraji, M., & Boroujeni, M. K. (2014) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-013-7467-z · Cited by 232
“[189] used whole analysis (microextraction and detection) inside a glass syringe.”
Ten years of dispersive liquid–liquid microextraction and derived techniques
Campillo, N., Viñas, P., Šandrejová, J., & Andruch, V. (2017) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2016.1224240 · Cited by 102
Metadata
- Authors
- Maya, F., Horstkotte, B., Estela, J. M., & Cerdà, V.
- Venue
- Analytical and Bioanalytical Chemistry
- Published
- 2012-06-15
- Volume
- 404
- Issue
- 3
- Pages
- 909-917
- ISSN
- 1618-2642 (ISSN-L)
- 1618-2650
- OpenAlex
- W2051740807
- Cited by
- 107
- References
- 8
- FWCI
- 8.45
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.