The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Dispersion of magnetic graphene oxide nanoparticles coated with a deep eutectic solvent using ultrasound assistance for preconcentration of methadone in biological and water samples followed by GC-FID and GC-MS
Abstract
Magnetic graphene nanoparticles coated with a new deep eutectic solvent (Fe 3 O 4 @GO-DES) were developed for efficient preconcentration of methadone. The extracted methadone was then analyzed by gas chromatography-flame ionization detection (GC-FID) or gas chromatography-mass spectrometry (GC-MS). Fe 3 O 4 @GO-DES were characterized by Fourier transform IR and X-ray diffraction techniques. Ultrasound was used to enhance the dispersion of the sorbent, with a high extraction recovery. Some parameters affecting the extraction recovery, such as pH, type of deep eutectic solvent, sample volume, amount of sorbent, extraction time, and type of eluent, were investigated. Under optimum conditions, the method developed was linear in the concentration range from 3 to 45,000 μg L -1 for GC-FID and from 0.1 to 500 μg L -1 for GC-MS, with a detection limit of 0.8 μg L -1 for GC-FID and 0.03 μg L -1 for GC-MS. The relative standard deviations (n = 6) as the intraday and interday precisions of the methadone spike at a concentration of 100 μg L -1 were 5.8% and 8.4% respectively for GC-FID. The preconcentration factor was 250. Relative recoveries from spiked plasma, urine, and water samples ranged from 95.1% to 101.5%.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The ultrasound accelerated the dispersion of the sorbent in the biological samples and enhanced the speed of migration of the methadone into the Fe 3 O 4 @GO-DES sorbent, which ensured high analyte recovery [130].”
From Hydrophobic deep eutectic solvents in microextraction techniques–A review (2020) · cites this paper as [130]
In the citing paper
“The new sorbent was successfully applied for efficient preconcentration of methadone from urine and plasma samples.”
From Hydrophobic deep eutectic solvents in microextraction techniques–A review (2020) · cites this paper as [130]
In the citing paper
“The most efficient of the three was TNO, at molar ratio of 1:2 (ChCl:TNO), due to the high recoveries it provided.”
From Microextraction Techniques with Deep Eutectic Solvents (2020) · cites this paper as [59]
In the citing paper
“The LOD by using this method with GC-FID was 0.8 μg/L, whilst with GC-MS it was 0.03 μg/L.”
From Microextraction Techniques with Deep Eutectic Solvents (2020) · cites this paper as [59]
In the citing paper
“The recoveries of methadone in different samples were as follow: in distilled water, 98.4–101.5%; in urine, 95.3–99.3%; and in plasma, 95.1–96.4% [59].”
From Microextraction Techniques with Deep Eutectic Solvents (2020) · cites this paper as [59]
3 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Deep eutectic solvents: syntheses, properties and applications
Zhang, Q., De Oliveira Vigier, K., Royer, S., & Jérôme, F. (2012) · Chemical Society Reviews · doi:10.1039/c2cs35178a · Cited by 4,899
Abbott, A. P., Boothby, D., Capper, G., Davies, D. L., & Rasheed, R. K. (2004) · Journal of the American Chemical Society · doi:10.1021/ja048266j · Cited by 4,340
New insights into the structure and reduction of graphite oxide
Gao, W., Alemany, L. B., Ci, L., & Ajayan, P. M. (2009) · Nature Chemistry · doi:10.1038/nchem.281 · Cited by 2,583
International Union of Pharmacology. XII. Classification of opioid receptors
Dhawan, B., Cesselin, F., Raghubir, R., Reisine, T., Bradley, P., Portoghese, P., & Hamon, M. (1996) · Pharmacological Reviews · doi:10.1016/s0031-6997(25)06958-3 · Cited by 732
Low melting mixtures in organic synthesis–an alternative to ionic liquids?
Ruß, C., & König, B. (2012) · Green Chemistry · doi:10.1039/c2gc36005e · Cited by 654
Graphene as a new sorbent in analytical chemistry
Sitko, R., Zawisza, B., & Malicka, E. (2013) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2013.05.011 · Cited by 373
Karimi, M., Dadfarnia, S., Shabani, A. M. H., Tamaddon, F., & Azadi, D. (2015) · Talanta · doi:10.1016/j.talanta.2015.07.021 · Cited by 182
Huang, Y., Wang, Y., Pan, Q., Wang, Y., Ding, X., Xu, K., Li, N., & Wen, Q. (2015) · Analytica Chimica Acta · doi:10.1016/j.aca.2015.03.048 · Cited by 176
Methadone maintenance treatment. A ten-year perspective
Dole, V. P. (1976) · JAMA · doi:10.1001/jama.235.19.2117 · Cited by 162
Wang, W., Ma, R., Wu, Q., Wang, C., & Wang, Z. (2013) · Journal of Chromatography A · doi:10.1016/j.chroma.2013.03.071 · Cited by 134
Research works printed but not linked: 1
- Shahriary L, Athawale AA. Graphene oxide synthesized by using modified Hummers approach. Int J Renew Energy Environ Eng. 2014;2:58–63.
Cited by
Hydrophobic deep eutectic solvents in microextraction techniques–A review
Makoś, P., Słupek, E., & Gębicki, J. (2020) · Microchemical Journal · doi:10.1016/j.microc.2019.104384 · Cited by 469
“The ultrasound accelerated the dispersion of the sorbent in the biological samples and enhanced the speed of migration of the methadone into the Fe3O4@GO-DES sorbent, which ensured high analyte recovery [130].”
MethodDeep eutectic solvents are not only effective extractants
Shishov, A., Pochivalov, A., Nugbienyo, L., Andruch, V., & Bulatov, A. (2020) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2020.115956 · Cited by 278
Devi, M., Moral, R., Thakuria, S., Mitra, A., & Paul, S. (2023) · ACS Omega · doi:10.1021/acsomega.2c07684 · Cited by 194
Ultrasound-assisted extraction of organic contaminants
Albero, B., Tadeo, J. L., & Pérez, R. A. (2019) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2019.07.007 · Cited by 120
Zarei, A. R., Nedaei, M., & Ghorbanian, S. A. (2018) · Journal of Chromatography A · doi:10.1016/j.chroma.2018.04.023 · Cited by 111
Metadata
- Authors
- Lamei, N., Ezoddin, M., Ardestani, M. S., & Abdi, K.
- Affiliations
- Tehran University of Medical Sciences (IR)
- Payame Noor University (IR)
- Corresponding author
- Abdi, Khosrou
- Venue
- Analytical and Bioanalytical Chemistry
- Published
- 2017-08-26
- Volume
- 409
- Issue
- 26
- Pages
- 6113-6121
- ISSN
- 1618-2642 (ISSN-L)
- 1618-2650
- OpenAlex
- W2746204178
- Cited by
- 73
- References
- 30
- Citations by year
- 2026: 6 · 2025: 7 · 2024: 9 · 2023: 8 · 2022: 9 · 2021: 6 · 2020: 10 · 2019: 8 · 2018: 9 · 2017: 1
- FWCI
- 5.36
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Analytical and Bioanalytical Chemistry (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Tehran University of Medical Sciences and Health Services
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
- Life Sciences › Pharmacology, Toxicology and Pharmaceutics › Toxicology › Forensic Toxicology and Drug Analysis
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Chromatography
- Keywords
- methadone, deep eutectic solvents, ultrasonic dispersion, preconcentration, plasma analysis, urine analysis, water analysis
- MeSH terms
- Adsorption, Analgesics, Opioid, Chromatography, Gas, Graphite, Humans, Methadone, Oxides, Solvents, Sonication, Water, Water Pollutants, Chemical, Solid Phase Extraction, Limit of Detection, Magnetite Nanoparticles
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Dispersion of magnetic graphene oxide nanoparticles coated with a deep eutectic solvent using ultrasound assistance for preconcentration of methadone in biological and water samples followed by GC-FID and GC-MS. https://app.cochat.ai/papers/10.1007/s00216-017-0547-8
- The paper
- Lamei, N., Ezoddin, M., Ardestani, M. S., & Abdi, K. (2017). Dispersion of magnetic graphene oxide nanoparticles coated with a deep eutectic solvent using ultrasound assistance for preconcentration of methadone in biological and water samples followed by GC-FID and GC-MS. Analytical and Bioanalytical Chemistry. https://doi.org/10.1007/s00216-017-0547-8
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.