Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.

Dispersion of magnetic graphene oxide nanoparticles coated with a deep eutectic solvent using ultrasound assistance for preconcentration of methadone in biological and water samples followed by GC-FID and GC-MS

Lamei, Navid, Ezoddin, Maryam, Ardestani, Mehdi Shafiee, Abdi, Khosrou · 2017 · Analytical and Bioanalytical Chemistry

Abstract

Magnetic graphene nanoparticles coated with a new deep eutectic solvent (Fe 3 O 4 @GO-DES) were developed for efficient preconcentration of methadone. The extracted methadone was then analyzed by gas chromatography-flame ionization detection (GC-FID) or gas chromatography-mass spectrometry (GC-MS). Fe 3 O 4 @GO-DES were characterized by Fourier transform IR and X-ray diffraction techniques. Ultrasound was used to enhance the dispersion of the sorbent, with a high extraction recovery. Some parameters affecting the extraction recovery, such as pH, type of deep eutectic solvent, sample volume, amount of sorbent, extraction time, and type of eluent, were investigated. Under optimum conditions, the method developed was linear in the concentration range from 3 to 45,000 μg L -1 for GC-FID and from 0.1 to 500 μg L -1 for GC-MS, with a detection limit of 0.8 μg L -1 for GC-FID and 0.03 μg L -1 for GC-MS. The relative standard deviations (n = 6) as the intraday and interday precisions of the methadone spike at a concentration of 100 μg L -1 were 5.8% and 8.4% respectively for GC-FID. The preconcentration factor was 250. Relative recoveries from spiked plasma, urine, and water samples ranged from 95.1% to 101.5%.

Overview

Integrity signals

Registry

Crossref · 10.1007/s00216-017-0547-8

Cites

30 of 30 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

3 more claims about this paper

Create a free account to see every claim other papers make about this one.

See all claims — free account

Citations

Cites

Show all 30 references

Research works printed but not linked: 1

  1. Shahriary L, Athawale AA. Graphene oxide synthesized by using modified Hummers approach. Int J Renew Energy Environ Eng. 2014;2:58–63.

Cited by

See all 73

Metadata

Authors
Lamei, N., Ezoddin, M., Ardestani, M. S., & Abdi, K.
Affiliations
  • Tehran University of Medical Sciences (IR)
  • Payame Noor University (IR)
Corresponding author
Abdi, Khosrou
Venue
Analytical and Bioanalytical Chemistry
Published
2017-08-26
Volume
409
Issue
26
Pages
6113-6121
ISSN
  • 1618-2642 (ISSN-L)
  • 1618-2650
OpenAlex
W2746204178
Cited by
73
References
30
Citations by year
2026: 6 · 2025: 7 · 2024: 9 · 2023: 8 · 2022: 9 · 2021: 6 · 2020: 10 · 2019: 8 · 2018: 9 · 2017: 1
FWCI
5.36
Type
journal article
Language
en
Open access
closed
Locations
  • Analytical and Bioanalytical Chemistry (publishedVersion)
  • PubMed (publishedVersion)
Funders
Tehran University of Medical Sciences and Health Services
Topics
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
  • Life Sciences › Pharmacology, Toxicology and Pharmaceutics › Toxicology › Forensic Toxicology and Drug Analysis
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Chromatography
Keywords
methadone, deep eutectic solvents, ultrasonic dispersion, preconcentration, plasma analysis, urine analysis, water analysis
MeSH terms
Adsorption, Analgesics, Opioid, Chromatography, Gas, Graphite, Humans, Methadone, Oxides, Solvents, Sonication, Water, Water Pollutants, Chemical, Solid Phase Extraction, Limit of Detection, Magnetite Nanoparticles

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Dispersion of magnetic graphene oxide nanoparticles coated with a deep eutectic solvent using ultrasound assistance for preconcentration of methadone in biological and water samples followed by GC-FID and GC-MS. https://app.cochat.ai/papers/10.1007/s00216-017-0547-8
The paper
Lamei, N., Ezoddin, M., Ardestani, M. S., & Abdi, K. (2017). Dispersion of magnetic graphene oxide nanoparticles coated with a deep eutectic solvent using ultrasound assistance for preconcentration of methadone in biological and water samples followed by GC-FID and GC-MS. Analytical and Bioanalytical Chemistry. https://doi.org/10.1007/s00216-017-0547-8

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.