New sample preparation method based on task-specific ionic liquids for extraction and determination of copper in urine and wastewater
The DOI matches its Crossref record; 33 of the 34 references it cites were found in a registry or an index.
Abstract
In this study, four hydrophilic ionic liquids (ILs) containing 1-alkyl-3-methylimidazolim cation and either salicylate or chloride anions were synthetized and studied as new task-specific ionic liquids (TSILs) suitable for aqueous biphasic system (ABS) formation and selective one-step extraction of copper(II). TSILs are designed so that the anion is responsible for forming the complex with metal(II) and preventing hydrolysis of metal cations at very strong alkaline pH, whereas the cation is responsible for selective extraction of metal(II)-salicylate complexes. It was found that 1-butyl-3-methylimidazolium salicylate could be used for selective extraction of Cu(II) in the presence of Zn(II), Cd(II), and Pb(II) at very alkaline solution without metal hydroxide formation. It was assumed that formation of metal(II)-salicylate complexes prevents the hydrolysis of the metal ions in alkaline solutions. The determined stability constants for Cu(II)-salicylate complexes, where salicylate was derived from different ionic liquids, indicated that there was no significant influence of the cation of the ionic liquid on the stability of the complexes. The ABS based on 1-butyl-3-methylimidazolium salicylate has been applied as the sample preparation step prior to voltammetric determination of Cu(II). The effect of volume of aqueous sample and IL and extraction time were investigated and optimum extraction conditions were determined. The obtained detection limits were 8 ng dm -3 . The optimi…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Electrochemical methods as differential pulse anodic stripping voltammetry were used for Cu determination in enriched imidazolium IL, using hanging drop Hg electrode [31].”
Citations
Cites
The Determination of Ionization Constants
Albert, A., & Serjeant, E. P. (1984) · Springer eBooks · doi:10.1007/978-94-009-5548-6 · Cited by 1,227 · cited 1×
“[30] and [Sal] is calculated from equation:”
Gutowski, K. E., Broker, G. A., Willauer, H. D., Huddleston, J. G., Swatloski, R. P., Holbrey, J. D., & Rogers, R. D. (2003) · Journal of the American Chemical Society · doi:10.1021/ja0351802 · Cited by 1,038 · cited 1×
“published this method for the first time [14].”
MethodTask-specific ionic liquids for the extraction of metal ions from aqueous solutions
Visser, A. E., Swatloski, R. P., Reichert, W. M., Davis Jr., J. H., Rogers, R. D., Mayton, R., Sheff, S., & Wierzbicki, A. (2001) · Chemical Communications · doi:10.1039/b008041l · Cited by 920 · cited 1×
“extraction [5] and still remains the most frequently employed system for this task [6].”
BackgroundAqueous two-phase systems for protein separation
Merchuk, J. C., Andrews, B. A., & Asenjo, J. A. (1998) · Journal of Chromatography B: Biomedical Sciences and Applications · doi:10.1016/s0378-4347(97)00594-x · Cited by 827 · cited 2×
“Tie-line length (TLL) was calculated using obtained values for YIL, YS, XIL, and XS and the following equation [28]:”
MethodAqueous biphasic systems: a boost brought about by using ionic liquids
Freire, M. G., Cláudio, A. F. M., Araújo, J. M. M., Coutinho, J. A. P., Marrucho, I. M., Lopes, J. N. C., & Rebelo, L. P. N. (2012) · Chemical Society Reviews · doi:10.1039/c2cs35151j · Cited by 817 · cited 1×
“These systems found numerous applications in green separation processes [15, 16].”
Chun, S., Dzyuba, S. V., & Bartsch, R. A. (2001) · Analytical Chemistry · doi:10.1021/ac010061v · Cited by 520 · cited 1×
“, crown ethers and calixarenes) dissolved in IL to complex metal ions [7], selective extraction of the metal ions through interaction with anions from IL [8], and task-specific ILs suitable for complexation of the metal ions either with specific functional groups attached to cation [9, 10] or with the anion [11].”
BackgroundTask-Specific Ionic Liquid for Solubilizing Metal Oxides
Nockemann, P., Thijs, B., Pittois, S., Thoen, J., Glorieux, C., Van Hecke, K., Van Meervelt, L., Kirchner, B., & Binnemans, K. (2006) · The Journal of Physical Chemistry B · doi:10.1021/jp0642995 · Cited by 457 · cited 1×
“, crown ethers and calixarenes) dissolved in IL to complex metal ions [7], selective extraction of the metal ions through interaction with anions from IL [8], and task-specific ILs suitable for complexation of the metal ions either with specific functional groups attached to cation [9, 10] or with the anion [11].”
BackgroundVentura, S. P. M., Neves, C. M. S. S., Freire, M. G., Marrucho, I. M., Oliveira, J., & Coutinho, J. A. P. (2009) · The Journal of Physical Chemistry B · doi:10.1021/jp903286d · Cited by 376 · cited 1×
“Different solvation of anion with water molecules directly influences on the ability of IL to form ABS [32].”
BackgroundIonic liquids in dispersive liquid-liquid microextraction
Trujillo-Rodríguez, M. J., Rocío-Bautista, P., Pino, V., & Afonso, A. M. (2013) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2013.06.008 · Cited by 276 · cited 1×
“Many application of hydrophobic ILs in microextraction procedures were published earlier [3, 4].”
BackgroundBillard, I., Ouadi, A., & Gaillard, C. (2011) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-4478-x · Cited by 274 · cited 1×
“extraction [5] and still remains the most frequently employed system for this task [6].”
BackgroundDispersive liquid–liquid microextraction in food analysis. A critical review
Viñas, P., Campillo, N., López-García, I., & Hernández-Córdoba, M. (2014) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-013-7344-9 · Cited by 211 · cited 5×
“Several liquid-liquid microextraction techniques such as single drop microextraction, dispersive liquid-liquid microextraction, and hollow fiber liquid-phase microextraction have been introduced as alternatives to the traditional sample preparation techniques based on LLE [2].”
MethodInfluentialIonic liquid-based aqueous two-phase systems and their applications in green separation processes
Li, Z., Pei, Y., Wang, H., Fan, J., & Wang, J. (2010) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2010.07.014 · Cited by 206 · cited 1×
“These systems found numerous applications in green separation processes [15, 16].”
BackgroundDimpe, K. M., & Nomngongo, P. N. (2016) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2016.05.023 · Cited by 202
Ferreira, A. M., Coutinho, J. A. P., Fernandes, A. M., & Freire, M. G. (2014) · Separation and Purification Technology · doi:10.1016/j.seppur.2014.02.036 · Cited by 196 · cited 1×
“, no detection of Cu(II) in the salt-rich phase was observed [33] and that extraction”
BackgroundEgorov, V. M., Djigailo, D. I., Momotenko, D. S., Chernyshov, D. V., Torocheshnikova, I. I., Smirnova, S. V., & Pletnev, I. V. (2010) · Talanta · doi:10.1016/j.talanta.2009.09.003 · Cited by 182 · cited 1×
“, crown ethers and calixarenes) dissolved in IL to complex metal ions [7], selective extraction of the metal ions through interaction with anions from IL [8], and task-specific ILs suitable for complexation of the metal ions either with specific functional groups attached to cation [9, 10] or with the anion [11].”
BackgroundAkama, Y., & Ahat, S. (2002) · Talanta · doi:10.1016/s0039-9140(02)00076-0 · Cited by 129 · cited 1×
“bromide ionic liquid [17, 18], extraction of Sc(III) by ABS based on carboxyl-functionalized phosphonium-based ILs [19], and selective extraction of Cr(III) applying 1-octyl-3-”
MethodIonic Liquid Based Aqueous Biphasic Systems with Controlled pH: The Ionic Liquid Cation Effect
Ventura, S. P. M., Sousa, S. G., Serafim, L. S., Lima, Á. S., Freire, M. G., & Coutinho, J. A. P. (2011) · Journal of Chemical & Engineering Data · doi:10.1021/je200714h · Cited by 120
Stanisz, E., Werner, J., & Zgoła-Grześkowiak, A. (2014) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2014.06.008 · Cited by 116 · cited 1×
“Many application of hydrophobic ILs in microextraction procedures were published earlier [3, 4].”
BackgroundAkama, Y., Ito, M., & TANAKA, S. (2000) · Talanta · doi:10.1016/s0039-9140(00)00555-5 · Cited by 104 · cited 1×
“bromide ionic liquid [17, 18], extraction of Sc(III) by ABS based on carboxyl-functionalized phosphonium-based ILs [19], and selective extraction of Cr(III) applying 1-octyl-3-”
MethodPartitioning of small organic molecules in aqueous biphasic systems
Rogers, R. D., Willauer, H. D., Griffin, S. T., & Huddleston, J. G. (1998) · Journal of Chromatography B Biomedical Sciences and Applications · doi:10.1016/s0378-4347(97)00661-0 · Cited by 96 · cited 1×
“Polymer-polymer, polymer-salt, or salt-salt aqueous biphasic systems have been widely used for separation of organic molecules and biomolecules [12, 13].”
BackgroundKodama, H., & Fujisawa, C. (2008) · Metallomics · doi:10.1039/b816011m · Cited by 92 · cited 1×
“Determination of copper(II) ions in biological samples is very important since it may be used as biochemical marker for some diseases such as Wilson disease, Menkes disease, hemochromatosis, biliary cirrhosis, thyrotoxicosis, various infections, and variety of other acute, chronic, or malignant diseases (including leu…”
BackgroundPurification of indium by solvent extraction with undiluted ionic liquids
Deferm, C., de Voorde, M. V., Luyten, J., Oosterhof, H., Fransaer, J., & Binnemans, K. (2016) · Green Chemistry · doi:10.1039/c6gc00586a · Cited by 87 · cited 1×
“, crown ethers and calixarenes) dissolved in IL to complex metal ions [7], selective extraction of the metal ions through interaction with anions from IL [8], and task-specific ILs suitable for complexation of the metal ions either with specific functional groups attached to cation [9, 10] or with the anion [11].”
BackgroundDepuydt, D., Dehaen, W., & Binnemans, K. (2015) · Industrial & Engineering Chemistry Research · doi:10.1021/acs.iecr.5b01910 · Cited by 70 · cited 1×
“bromide ionic liquid [17, 18], extraction of Sc(III) by ABS based on carboxyl-functionalized phosphonium-based ILs [19], and selective extraction of Cr(III) applying 1-octyl-3-”
MethodKozonoi, N., & Ikeda, Y. (2007) · Monatshefte für Chemie - Chemical Monthly · doi:10.1007/s00706-007-0727-x · Cited by 66 · cited 1×
“, crown ethers and calixarenes) dissolved in IL to complex metal ions [7], selective extraction of the metal ions through interaction with anions from IL [8], and task-specific ILs suitable for complexation of the metal ions either with specific functional groups attached to cation [9, 10] or with the anion [11].”
BackgroundIonic-Liquid-Based Aqueous Biphasic Systems
Freire, M. G. (2016) · Green chemistry and sustainable technology · doi:10.1007/978-3-662-52875-4 · Cited by 58
Wen, X., Deng, Q., & Guo, J. (2011) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2011.05.095 · Cited by 57 · cited 1×
“15 μg·dm) obtained by ionic liquid-based single drop microextraction using 1-butyl-3methylimidazolium hexafluorophosphate as a sample preparation step [34].”
MethodDinis, T. B. V., Passos, H., Lima, D. L. D., Esteves, V. I., Coutinho, J. A. P., & Freire, M. G. (2015) · Green Chemistry · doi:10.1039/c5gc00077g · Cited by 52 · cited 1×
“Polymer-polymer, polymer-salt, or salt-salt aqueous biphasic systems have been widely used for separation of organic molecules and biomolecules [12, 13].”
Kidani, K., & Imura, H. (2010) · Talanta · doi:10.1016/j.talanta.2010.09.011 · Cited by 41 · cited 3×
“aConfirmed by NMR spectroscopy after purification [25, 26]”
BackgroundToxicity reduction of imidazolium-based ionic liquids by the oxygenation of the alkyl substituent
Vraneš, M., Tot, A. S., Jovanović-Šanta, S., Karaman, M. A., Dožić, S., Tešanović, K., Kojić, V., & Gadžurić, S. B. (2016) · RSC Advances · doi:10.1039/c6ra16182k · Cited by 36 · cited 2×
“aConfirmed by NMR spectroscopy after purification [25, 26]”
MethodSelf-citationDimitrijević, A., Trtić‐Petrović, T. M., Vraneš, M., Papović, S. M., Tot, A. S., Dožić, S., & Gadžurić, S. B. (2015) · Journal of Chemical & Engineering Data · doi:10.1021/acs.jced.5b00697 · Cited by 33 · cited 1×
“ILs were synthesized by procedures published elsewhere [26, 27].”
MethodSelf-citationSadeghi, S., & Moghaddam, A. Z. (2016) · Journal of Molecular Liquids · doi:10.1016/j.molliq.2016.06.056 · Cited by 26
Sepúlveda, R., Romero, J., & Sánchez, J. (2014) · Journal of Chemical Technology & Biotechnology · doi:10.1002/jctb.4330 · Cited by 21 · cited 1×
“This is distinct from previous studies of the Cu(II) extraction since these studies generally used hydrophobic chelating agent to solubilize the metal in the IL phase [24, 25].”
BackgroundTeixeira, F., Pérez, A., Madden, W., Hernández, L., Carpio, E. D., & Lubes, V. R. (2016) · Journal of Molecular Liquids · doi:10.1016/j.molliq.2016.10.012 · Cited by 9 · cited 1×
“Salicylate anion was selected in regard to its biodegradability and ability to form stable complexes with copper(II) with pronounced anti-inflammatory and antifungal activities [31], and chloride anion was chosen for comparison.”
Background
Cited by
Herce-Sesa, B., López-López, J. A., & Moreno, C. (2021) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2021.116398 · Cited by 86
Ražić, S., Arsenijević, J., Mračević, S. Đ., Mušović, J., & Trtić‐Petrović, T. M. (2023) · The Analyst · doi:10.1039/d3an00498h · Cited by 94
Self-citationPacheco-Fernández, I., González-Martín, R., e Silva, F. A., Freire, M. G., & Pino, V. (2021) · Analytica Chimica Acta · doi:10.1016/j.aca.2020.08.022 · Cited by 69
Llaver, M., Fiorentini, E. F., Quintas, P. Y., Oviedo, M. N., Botella, M. B., & Wuilloud, R. G. (2022) · Advances in Sample Preparation · doi:10.1016/j.sampre.2022.100004 · Cited by 68
Oke, E. A., & Ijardar, S. P. (2021) · Journal of Molecular Liquids · doi:10.1016/j.molliq.2021.116027 · Cited by 48
Metadata
- Authors
- Trtić-Petrović, T., Dimitrijević, A., Zdolšek, N., Đorđević, J., Tot, A., Vraneš, M., & Gadžurić, S.
- Affiliations
- University of Belgrade (RS)
- University of Novi Sad (RS)
- Venue
- Analytical and Bioanalytical Chemistry
- Published
- 2017-11-02
- Volume
- 410
- Issue
- 1
- Pages
- 155-166
- ISSN
- 1618-2642 (ISSN-L)
- 1618-2650
- OpenAlex
- W2766935846
- Semantic Scholar
- 610c3f984ec6920c2b44a046980346eabd35263e
- Cited by
- 22
- References
- 34
- Citations by year
- 2026: 2 · 2025: 1 · 2024: 1 · 2023: 3 · 2022: 3 · 2021: 4 · 2020: 1 · 2019: 6 · 2018: 1
- FWCI
- 1.53
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Analytical and Bioanalytical Chemistry (publishedVersion)
- PubMed (publishedVersion)
- VinaR (Institute of Nuclear Sciences "Vinča") (submittedVersion)
- Funders
- Ministry of Education, Science and Technological Development of Serbia under project contracts (III 45006 and ON 172012)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
- Physical Sciences › Chemical Engineering › Filtration and Separation › Chemical and Physical Properties in Aqueous Solutions
- Physical Sciences › Chemistry › Physical and Theoretical Chemistry › Ionic liquids properties and applications
- Keywords
- task-specific ionic liquids, copper(II) extraction, aqueous two-phase systems, complex stability constants, voltammetric determination, selective metal recovery
- MeSH terms
- Anions, Cations, Copper, Chemical Fractionation, Humans, Imidazoles, Salicylates, Water Pollutants, Chemical, Phase Transition, Ionic Liquids, Electrochemical Techniques, Coordination Complexes, Limit of Detection, Wastewater
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.