Cited by 45

Multi‐Attribute PAT for UF/DF of Proteins—Monitoring Concentration, Particle Sizes, and Buffer Exchange

Rolinger, Laura, Rüdt, Matthias, Diehm, Juliane, Chow-Hubbertz, Jessica, Heitmann, Martin, Schleper, Stefan, Hubbuch, Jürgen·2020·Analytical and Bioanalytical Chemistry

Abstract

Ultrafiltration/diafiltration (UF/DF) plays an important role in the manufacturing of biopharmaceuticals. Monitoring critical process parameters and quality attributes by process analytical technology (PAT) during those steps can facilitate process development and assure consistent quality in production processes. In this study, a lab-scale cross-flow filtration (CFF) device was equipped with a variable pathlength (VP) ultraviolet and visible (UV/Vis) spectrometer, a light scattering photometer, and a liquid density sensor (microLDS). Based on the measured signals, the protein concentration, buffer exchange, apparent molecular weight, and hydrodynamic radius were monitored. The setup was tested in three case studies. First, lysozyme was used in an UF/DF run to show the comparability of on-line and off-line measurements. The corresponding correlation coefficients exceeded 0.97. Next, urea-induced changes in protein size of glucose oxidase (GOx) were monitored during two DF steps. Here, correlation coefficients were ≥ 0.92 for static light scattering (SLS) and dynamic light scattering (DLS). The correlation coefficient for the protein concentration was 0.82, possibly due to time-dependent protein precipitation. Finally, a case study was conducted with a monoclonal antibody (mAb) to show the full potential of this setup. Again, off-line and on-line measurements were in good agreement with all correlation coefficients exceeding 0.92. The protein concentration could be monitored i…

Integrity signals

Registry

Crossref · 10.1007/s00216-019-02318-8

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • A variable pathlength UV-Vis spectrometer has been utilized for the in-line monitoring of protein concentration during UFDF on a lab scale.

    “A variable pathlength UV‐Vis spectrometer has already been utilized for the in‐line monitoring of protein concentration during the UFDF on a lab scale [82].”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Rolinger, L., Rüdt, M., Diehm, J., Chow-Hubbertz, J., Heitmann, M., Schleper, S., & Hubbuch, J.
Venue
Analytical and Bioanalytical Chemistry
Published
2020-02-18
Volume
412
Issue
9
Pages
2123-2136
ISSN
  • 1618-2642
  • 1618-2650
Cited by
45
References
1
Language
en

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review