Cited by 41Metabolomics and Mass Spectrometry StudiesMass Spectrometry Techniques and ApplicationsAnalytical Chemistry and Chromatography

Parallel targeted and non-targeted quantitative analysis of steroids in human serum and peritoneal fluid by liquid chromatography high-resolution mass spectrometry

Open access
Andrieu, Thomas, du Toit, Therina, Vogt, Bruno, Mueller, Michael D., Groessl, Michael·2022·Analytical and Bioanalytical Chemistry

Abstract

We developed and validated a liquid chromatography high-resolution mass spectrometry method for the absolute quantification of 51 steroids for clinical analysis of human serum and, for the first time, peritoneal fluid. Data acquisition was performed in both targeted and untargeted mode simultaneously, thus allowing the accurate and precise quantification of the main components of the classical steroid pathways (17 steroids) as well as the analysis of 34 additional non-classical steroids. For targeted analysis, validation was performed according to FDA guidelines, resulting, among other parameters, in accuracy < 13% RSD and precision < 10% relative error, for both inter- and intra-day validation runs. By establishing steroid-specific response factors, the calibration curves of the targeted analytes can be extended to untargeted analytes. This approach opens novel possibilities for the post hoc analysis of clinical samples as the data can be examined for virtually any steroid even after data acquisition, enabling facile absolute quantification once a standard becomes available. We demonstrate the applicability of the approach to evaluate the differences in steroid content between peripheral serum and peritoneal fluid across the menstrual cycle phases, as well as the effect of the synthetic gestagen dienogest on the steroid metabolome.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s00216-022-03881-3

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

The citation lists haven’t been fetched yet

References 24 · Cited by 41

Authors
Andrieu, T., du Toit, T., Vogt, B., Mueller, M. D., & Groessl, M.
Affiliations
University of Bern (CH)
Corresponding author
Groessl, Michael
Venue
Analytical and Bioanalytical Chemistry
Published
2022-01-19
Volume
414
Issue
25
Pages
7461-7472
ISSN
  • 1618-2642 (ISSN-L)
  • 1618-2650
OpenAlex
W4206104424
Cited by
41
References
24
Citations by year
2026: 6 · 2025: 11 · 2024: 17 · 2023: 5 · 2022: 2
FWCI
2.86
Type
journal article
Language
en
Open access
Locations
  • Analytical and Bioanalytical Chemistry (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • BORIS (University Library Bern) (submittedVersion, cc-by)
  • Open Access CRIS of the University of Bern
Funders
  • H2020 European Research Council (101023999)
  • Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung (198281, IZSEZ0_189926/1)
  • University of Bern
Topics
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Metabolomics and Mass Spectrometry Studies
  • Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
  • Physical Sciences › Chemistry › Spectroscopy › Analytical Chemistry and Chromatography
Keywords
steroid quantification, human serum, peritoneal fluid, menstrual cycle, dienogest, steroid metabolome, method validation
MeSH terms
Ascitic Fluid, Chromatography, High Pressure Liquid, Chromatography, Liquid, Humans, Progestins, Steroids, Tandem Mass Spectrometry

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review