Effect of Voxel Size on 3D Micro-CT Analysis of Cortical Bone Porosity
The DOI matches its Crossref record.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Osteoporosis studies have previously shown that the Ct.Po in male vertebrates is distinctly lower than in females and in the latter increases strongly with age”
From Experimental Aqueous Alteration of Cortical Bone Microarchitecture Analyzed by Quantitative Micro-Computed Tomography (2021) · cites this paper as Cooper et al., 2007
In the citing paper
“the Ct.Po avg value of 1.7 ± 0.3% from all CB samples analyzed here is significantly lower than the Ct.Po determined for the femur in a male human, which was found to range between 2 and 5%”
From Experimental Aqueous Alteration of Cortical Bone Microarchitecture Analyzed by Quantitative Micro-Computed Tomography (2021) · cites this paper as Cooper et al., 2007
In the citing paper
“However, in quantitative CB research, this approach still suffers from a number of technical and analytical obstacles, such as the lack of a standardized nomenclature or of guidelines for the assessment of morphological parameters used across different scientific disciplines.”
From Experimental Aqueous Alteration of Cortical Bone Microarchitecture Analyzed by Quantitative Micro-Computed Tomography (2021) · cites this paper as Cooper et al., 2007
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 26
- Cooper DM, Matyas JR, Katzenberg MA, Hallgrimsson B (2004) Comparison of microcomputed tomographic and microradiographic measurements of cortical bone porosity. Calcif Tissue Int 74:437–447 · DOI · Paper page
- Cooper DM, Turinsky AL, Sensen CW, Hallgrimsson B (2003) Quantitative 3D analysis of the canal network in cortical bone by micro-computed tomography. Anat Rec 274B:169–179 · DOI · Paper page
- Basillais A, Chappard C, Bensamoun S, Brunet-Imbault B, Ho Ba Tho M, Benhamou C (2004) Three Dimensional Characterization of Cortical Bone Porosity on Microcomputed Tomography Images: A New Method of Evaluation. J Bone Miner Res 19:s112–113
- Bousson V, Peyrin F, Bergot C, Hausard M, Sautet A, Laredo JD (2004) Cortical bone in the human femoral neck: three-dimensional appearance and porosity using synchrotron radiation. J Bone Miner Res 19:794–801 · DOI · Paper page
- Jones AC, Milthorpe B, Averdunk H, Limaye A, Senden TJ, Sakellariou A, Sheppard AP, Sok RM, Knackstedt MA, Brandwood A, Rohner D, Hutmacher DW (2004) Analysis of 3D bone ingrowth into polymer scaffolds via micro-computed tomography imaging. Biomaterials 25:4947–4954 · doi:10.1016/j.biomaterials.2004.01.047
- Wachter NJ, Augat P, Krischak GD, Mentzel M, Kinzl L, Claes L (2001a) Prediction of cortical bone porosity in vitro by microcomputed tomography. Calcif Tissue Int 68:38–42 · DOI
- Wachter NJ, Augat P, Krischak GD, Sarkar MR, Mentzel M, Kinzl L, Claes L (2001b) Prediction of strength of cortical bone in vitro by microcomputed tomography. Clin Biomech (Bristol, Avon) 16:252–256 · DOI · Paper page
- Schneider P, Stampanoni M, Donahue L, Muller R (2004) Bone Vasculature as a New Marker for Bone Quality Varies within the Femoral Diaphysis of Two Genetically Distinct Mouse Strains. J Bone Miner Res 19:s241
- Matsumoto T, Yoshino M, Asano T, Uesugi K, Todoh M, Tanaka M (2006) Monochromatic synchrotron radiation {micro}CT reveals disuse-mediated canal network rarefaction in cortical bone of growing rat tibiae. J Appl Physiol 100:274–280 · DOI
- Muller R, Koller B, Hildebrand T, Laib A, Gianolini S, Ruegsegger P (1996) Resolution dependency of microstructural properties of cancellous bone based on three-dimensional mu-tomography. Technol Health Care 4:113–119 · doi:10.3233/thc-1996-4112
- Peyrin F, Salome M, Cloetens P, Laval-Jeantet AM, Ritman E, Ruegsegger P (1998) Micro-CT examinations of trabecular bone samples at different resolutions: 14, 7 and 2 micron level. Technol Health Care 6:391–401 · doi:10.3233/thc-1998-65-611
- Kothari M, Keaveny TM, Lin JC, Newitt DC, Genant HK, Majumdar S (1998) Impact of spatial resolution on the prediction of trabecular architecture parameters. Bone 22:437–443 · DOI
- Tabor Z (2004) Analysis of the influence of image resolution on the discriminating power of trabecular bone architectural parameters. Bone 34:170–179 · DOI
- Majumdar S, Newitt D, Mathur A, Osman D, Gies A, Chiu E, Lotz J, Kinney J, Genant H (1996) Magnetic resonance imaging of trabecular bone structure in the distal radius: relationship with X-ray tomographic microscopy and biomechanics. Osteoporos Int 6:376–385 · doi:10.1007/bf01623011
- Vieth V, Link TM, Lotter A, Persigehl T, Newitt D, Heindel W, Majumdar S (2001) Does the trabecular bone structure depicted by high-resolution MRI of the calcaneus reflect the true bone structure? Invest Radiol 36:210–217 · doi:10.1097/00004424-200104000-00003
- Pothuaud L, Laib A, Levitz P, Benhamou CL, Majumdar S (2002) Three-dimensionalline skeleton graph analysis of high-resolution magnetic resonance images: a validation study from 34–microm-resolution microcomputed tomography. J Bone Miner Res 17:1883–1895 · doi:10.1359/jbmr.2002.17.10.1883
- Last D, Peyrin F, Guillot G (2005) Accuracy of 3D MR microscopy for trabecular bone assessment: a comparative study on calcaneus samples using 3D synchrotron radiation microtomography. Magma 18:26–34 · doi:10.1007/s10334-004-0075-3
- Kim DG, Christopherson GT, Dong XN, Fyhrie DP, Yeni YN (2004) The effect of microcomputed tomography scanning and reconstruction voxel size on the accuracy of stereological measurements in human cancellous bone. Bone 35:1375–1382 · DOI
- Feldkamp LA, Davis LC, Kress JW (1984) Practical cone-beam algorithm. J Opt Soc Am 1:612–619 · DOI · Paper page
- Borah B, Gross GJ, Dufresne TE, Smith TS, Cockman MD, Chmielewski PA, Lundy MW, Hartke JR, Sod EW (2001) Three-dimensional microimaging (MRmicroI and microCT), finite element modeling, and rapid prototyping provide unique insights into bone architecture in osteoporosis. Anat Rec 265:101–110 · DOI · Paper page
- Lin AS, Barrows TH, Cartmell SH, Guldberg RE (2003) Microarchitectural and mechanical characterization of oriented porous polymer scaffolds. Biomaterials 24:481–489 · DOI · Paper page
- Tabachnick BG, Fidell LS (2001) Using Multivariate Statistics. Allyn and Bacon, Toronto
- Van de Casteele E, Van Dyck D, Sijbers J, Raman E (2004) The effect of beam hardening on resolution in X-ray microtomography. SPIE 5370:2089–2096
- Majumdar S, Newitt D, Jergas M, Gies A, Chiu E, Osman D, Keltner J, Keyak J, Genant H (1995) Evaluation of technical factors affecting the quantification of trabecular bone structure using magnetic resonance imaging. Bone 17:417–430 · DOI · Paper page
- Bernhardt R, Scharnweber D, Muller B, Thurner P, Schliephake H, Wyss P, Beckmann F, Goebbels J, Worch H (2004) Comparison of microfocus- and synchrotron X-ray tomography for the analysis of osteointegration around Ti6Al4V implants. Eur Cell Mater 7:42–51 · DOI
- Hwang SN, Wehrli FW (2002) Subvoxel processing: a method for reducing partial volume blurring with application to in vivo MR images of trabecular bone. Magn Reson Med 47:948–957 · DOI
Cited by
Nishiyama, K. K., Macdonald, H. M., Buie, H. R., Hanley, D. A., & Boyd, S. K. (2010) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.091020 · Cited by 313
Olubamiji, A. D., Izadifar, Z., Si, J. L., Cooper, D. M. L., Eames, B. F., & Chen, D. X. (2016) · Biofabrication · doi:10.1088/1758-5090/8/2/025020 · Cited by 174
“A region of interest that consists of 4.0 × 4.0 mm2 of 80 image slices selected from each dataset were thresholded to distinguish scaffolds frombackground noise and pore voids as previously described in (Lin et al 2003, Cooper et al 2007).”
MethodInfluentialSelf-citationSharma (2018) · doi:10.1016/j.bone.2018.01.019 · Cited by 70
“While there are many studies in humans and rats that report a decrease in bone volume fraction due to estrogen deficiency, especially in cancellous bone, only recently have high-resolution analyses been performed to assess changes in bone microporosity, including the vascular porosity that houses the bone vasculature…”
BackgroundKral, A. G., Ziegler, A., Tütken, T., & Geisler, T. (2021) · Frontiers in Earth Science · doi:10.3389/feart.2021.609496 · Cited by 10
Metadata
- Authors
- Cooper, D., Turinsky, A., Sensen, C., & Hallgrimsson, B.
- Venue
- Calcified Tissue International
- Published
- 2007-03
- Volume
- 80
- Issue
- 3
- Pages
- 211-219
- ISSN
- 0171-967X
- 1432-0827
- Cited by
- 96
- References
- 0
- Language
- en
- Licence
- www.springer.com/tdm (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effect of Voxel Size on 3D Micro-CT Analysis of Cortical Bone Porosity. https://app.cochat.ai/papers/10.1007/s00223-005-0274-6
- The paper
- Cooper, D., Turinsky, A., Sensen, C., & Hallgrimsson, B. (2007). Effect of Voxel Size on 3D Micro-CT Analysis of Cortical Bone Porosity. Calcified Tissue International. https://doi.org/10.1007/s00223-005-0274-6
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.