Prediction of cortical bone porosity in vitro by microcomputed tomography.
The DOI matches its OpenAlex record.
Abstract
The high importance of intracortical porosity for mechanical strength of cortical bone has been established. The contribution of other parameters of microstructure such as osteon dimensions for strength is in discussion. The aim of this study was to evaluate the predictive value of microcomputed tomography (mCT) for porosity and other microstructural parameters of cortical bone in cortical bone biopsies. Femoral cortical bone specimens from the middiaphysis of 24 patients were harvested during the procedure of total hip replacement at the location where normally one hole (Ø 4.5 mm) for the relief of the intramedullary pressure is placed. In vitro intracortical porosity and bone mineral density (BMD) measurements by mCT were compared with structural parameters assessed in histological sections of the same specimens. A strong correlation was found between intracortical porosity measured by mCT and histological porosity (r = 0.95, P <0.0001). Porosity measured by mCT was also a strong predictor for other parameters describing dimensions of porous structures. BMD?1 was associated with osteonal area (r = -0.76, P <0.0001). We consider the measurement of porosity by mCT as a very potent procedure for assessing intracortical porosity and parameters related to porous structures of cortical bone nondestructively in vitro.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Mirzaali, M. J., Schwiedrzik, J. J., Thaiwichai, S., Best, J. P., Michler, J., Zysset, P. K., & Wolfram, U. (2016) · Bone · doi:10.1016/j.bone.2015.11.018 · Cited by 325
Nishiyama, K. K., Macdonald, H. M., Buie, H. R., Hanley, D. A., & Boyd, S. K. (2010) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.091020 · Cited by 313
The dependence of transversely isotropic elasticity of human femoral cortical bone on porosity
Neil Dong, X., & Edward Guo, X. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2003.12.011 · Cited by 302
Quantitative 3D analysis of the canal network in cortical bone by micro‐computed tomography
Cooper, D. M. L., Turinsky, A. L., Sensen, C. W., & Hallgrímsson, B. (2003) · The Anatomical Record Part B: The New Anatomist · doi:10.1002/ar.b.10024 · Cited by 208
Nishiyama, K. K., Macdonald, H. M., Moore, S. A., Fung, T., Boyd, S. K., & McKay, H. A. (2012) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.552 · Cited by 122
Metadata
- Authors
- Wachter, N. J., Augat, P., Krischak, G. D., Mentzel, M., Kinzl, L., & Claes, L.
- Venue
- PubMed
- Publisher
- National Institutes of Health
- Published
- 2001-01-01
- Volume
- 68
- Issue
- 1
- Pages
- 38-42
- OpenAlex
- W2331241421
- Cited by
- 67
- References
- 0
- FWCI
- 1.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Prediction of cortical bone porosity in vitro by microcomputed tomography. https://app.cochat.ai/papers/10.1007/s002230001182
- The paper
- Wachter, N. J., Augat, P., Krischak, G. D., Mentzel, M., Kinzl, L., & Claes, L. (2001). Prediction of cortical bone porosity in vitro by microcomputed tomography. PubMed. https://doi.org/10.1007/s002230001182
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.