The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Assessment of radiation dose awareness among pediatricians
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Estimated Risks of Radiation-Induced Fatal Cancer from Pediatric CT
Brenner, D. J., Elliston, C. D., Hall, E. J., & Berdon, W. E. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.176.2.1760289 · Cited by 3,222 · cited 4×
“Only 6% of respondents recalled the approximately 1 in 1,000 risk published [10].”
BackgroundMethodInfluential
Cited by
Hoffmann, T. C., & Del Mar, C. (2015) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2014.6016 · Cited by 707
Increasing utilization of computed tomography in the adult emergency department, 2000–2005
Broder, J., & Warshauer, D. M. (2006) · Emergency Radiology · doi:10.1007/s10140-006-0493-9 · Cited by 478
Cancer risks associated with external radiation from diagnostic imaging procedures
Linet, M. S., Slovis, T. L., Miller, D. L., Kleinerman, R., Lee, C., Rajaraman, P., & Berrington de Gonzalez, A. (2012) · CA: A Cancer Journal for Clinicians · doi:10.3322/caac.21132 · Cited by 420
Metadata
- Authors
- Thomas, K. E., Parnell-Parmley, J. E., Haidar, S., Moineddin, R., Charkot, E., BenDavid, G., & Krajewski, C.
- Venue
- Pediatric Radiology
- Published
- 2006-05-13
- Volume
- 36
- Issue
- 8
- Pages
- 823-832
- ISSN
- 0301-0449 (ISSN-L)
- 1432-1998
- OpenAlex
- W2011188556
- Cited by
- 196
- References
- 1
- FWCI
- 7.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Assessment of radiation dose awareness among pediatricians. https://app.cochat.ai/papers/10.1007/s00247-006-0170-x
- The paper
- Thomas, K. E., Parnell-Parmley, J. E., Haidar, S., Moineddin, R., Charkot, E., BenDavid, G., & Krajewski, C. (2006). Assessment of radiation dose awareness among pediatricians. Pediatric Radiology. https://doi.org/10.1007/s00247-006-0170-x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.