Artificial intelligence in paediatric radiology: international survey of health care professionals’ opinions
The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
Background The nature of paediatric radiology work poses several challenges for developing and implementing artificial intelligence (AI) tools, but opinions of those working in the field are currently unknown. Objective To evaluate the attitudes and perceptions toward AI amongst health care professionals working within children's imaging services. Materials and methods A web-based questionnaire was distributed to the membership of several paediatric and general radiological societies over a 4-month period (1 Feb - 31 May 2020). Survey questions covered attitudes toward AI in general, future impacts and suggested areas for development specifically within paediatric imaging. Results Two hundred and forty responses were collected with the majority being from radiologists (159/240, 66.3%; 95% confidence interval [CI] 59.8-72.2%) or allied health care professionals (72/240, 31.3%; 95% CI 25.4-37.5%). Respondents agreed that AI could potentially alert radiologists to imaging abnormalities (148/240, 61.7%; 95% CI 55.2-67.9%) but preferred that results were checked by a human (200/240, 83.3%; 95% CI 78.0-87.8%). The majority did not believe jobs in paediatric radiology would be replaced by AI (205/240, 85.4%; 95% CI 80.3-89.6%) and that the development of AI tools should focus on improved diagnostic accuracy (77/240, 32.1%; 95% CI 26.2-38.4%), workflow efficiencies (60/240, 25.0%; 95% CI 19.7-30.9%) and patient safety (54/240, 22.5%; 95% CI 17.4-28.3%). The majority of European Socie…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Eight studies reported on facilitating factors that relate to the professionals’ attitude towards their profession, such as as reducing their fear of job superflousness [41, 42].”
In the citing paper
“Hereby, a facilitating factor is that the outcomes and clinical effectivenes of AI applications should be evidence-based, ideally relying on large randomized controlled trials (RCTs) to support claims about its effectiveness and safety [36, 38, 39, 42, 58], while the development process itself should be transparent [63] and the AI system used should be explainable and verifiable [63].”
Citations
Cites
Some Studies in Machine Learning Using the Game of Checkers
Samuel, A. L. (1959) · IBM Journal of Research and Development · doi:10.1147/rd.33.0210 · Cited by 4,443
International evaluation of an AI system for breast cancer screening
McKinney, S. M., Sieniek, M., Godbole, V., Godwin, J., Antropova, N., Ashrafian, H., Back, T., Chesus, M., Corrado, G. S., Darzi, A., et al. (2020) · Nature · doi:10.1038/s41586-019-1799-6 · Cited by 3,287 · cited 1×
“, breast mammography screening [5], lung nodule detection [6]), in some cases with superior performance to human readers [7], but these tools have mostly related to adult imaging.”
BackgroundLiu, X., Faes, L., Kale, A. U., Wagner, S. K., Fu, D. J., Bruynseels, A., Mahendiran, T., Moraes, G., Shamdas, M., Kern, C., et al. (2019) · The Lancet Digital Health · doi:10.1016/s2589-7500(19)30123-2 · Cited by 1,883
Benjamens, S., Dhunnoo, P., & Meskó, B. (2020) · npj Digital Medicine · doi:10.1038/s41746-020-00324-0 · Cited by 1,215 · cited 1×
“Although it is encouraging that several AI tools have now ach i eved Un i t ed S t a t e s Food and Drug Administration (FDA) approval for clinical usage [8], there are none related to paediatric imaging.”
BackgroundMedical students' attitude towards artificial intelligence: a multicentre survey
Pinto dos Santos, D., Giese, D., Brodehl, S., Chon, S. H., Staab, W., Kleinert, R., Maintz, D., & Baeßler, B. (2019) · European Radiology · doi:10.1007/s00330-018-5601-1 · Cited by 754
AI for radiographic COVID-19 detection selects shortcuts over signal
DeGrave, A. J., Janizek, J. D., & Lee, S.-I. (2021) · Nature Machine Intelligence · doi:10.1038/s42256-021-00338-7 · Cited by 631
Gong, B., Nugent, J. P., Guest, W., Parker, W., Chang, P. J., Khosa, F., & Nicolaou, S. (2019) · Academic Radiology · doi:10.1016/j.acra.2018.10.007 · Cited by 325
Artificial intelligence in diagnostic imaging: impact on the radiography profession
Hardy, M., & Harvey, H. (2020) · The British Journal of Radiology · doi:10.1259/bjr.20190840 · Cited by 255
Baldwin, D. R., Gustafson, J., Pickup, L., Arteta, C., Novotny, P., Declerck, J., Kadir, T., Figueiras, C., Sterba, A., Exell, A., et al. (2020) · Thorax · doi:10.1136/thoraxjnl-2019-214104 · Cited by 207
European Society of Radiology (ESR) (2019) · Insights into Imaging · doi:10.1186/s13244-019-0798-3 · Cited by 196
Cited by
Chen, M., Zhang, B., Cai, Z., Seery, S., Gonzalez, M. J., Ali, N. M., Ren, R., Qiao, Y., Xue, P., & Jiang, Y. (2022) · Frontiers in Medicine · doi:10.3389/fmed.2022.990604 · Cited by 258
Hua, D., Petrina, N., Young, N., Cho, J., & Poon, S. K.-S. (2023) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2023.102698 · Cited by 148
Catalina, Q. M., Fuster-Casanovas, A., Vidal-Alaball, J., Escalé-Besa, A., Marin-Gomez, F. X., Femenia, J., & Solé-Casals, J. (2023) · DIGITAL HEALTH · doi:10.1177/20552076231180511 · Cited by 71
Radiologists’ perceptions on AI integration: An in-depth survey study
Cè, M., Ibba, S., Cellina, M., Tancredi, C., Fantesini, A., Fazzini, D., Fortunati, A., Perazzo, C., Presta, R., Montanari, R., et al. (2024) · European Journal of Radiology · doi:10.1016/j.ejrad.2024.111590 · Cited by 43
Henzler, D., Schmidt, S., Koçar, A., Herdegen, S., Lindinger, G. L., Maris, M. T., Bak, M. A. R., Willems, D. L., Tan, H. L., Lauerer, M., et al. (2025) · BMC Health Services Research · doi:10.1186/s12913-025-12664-2 · Cited by 54
“For instance, the lack of responsible personnel [87], insufficient funding [42], overall lack of organizational support [37], such as from the organization’s leadership, and compatibility issues between AI systems and existing clinical treatment meth-ods as well as the in-use digital system [62]…”
Influential
Metadata
- Authors
- Shelmerdine, S. C., Rosendahl, K., & Arthurs, O. J.
- Affiliations
- St George's Hospital (GB)
- University Hospital of North Norway (NO)
- Great Ormond Street Hospital (GB)
- Corresponding author
- Shelmerdine, Susan C.
- Venue
- Pediatric Radiology
- Published
- 2021-10-12
- Volume
- 52
- Issue
- 1
- Pages
- 30-41
- ISSN
- 0301-0449 (ISSN-L)
- 1432-1998
- OpenAlex
- W3205575183
- Cited by
- 41
- References
- 26
- Citations by year
- 2026: 9 · 2025: 12 · 2024: 10 · 2023: 7 · 2022: 3
- FWCI
- 1.48
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- www.springer.com/tdm (vor)
- Locations
- Pediatric Radiology (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institute for Health Research (NIHR-CDF-2017-10-037)
- Topics
- Health Sciences › Medicine › Health Informatics › Artificial Intelligence in Healthcare and Education
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiology practices and education
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiomics and Machine Learning in Medical Imaging
- Keywords
- artificial intelligence, pediatric radiology, clinician attitudes, radiologists, allied health professionals, AI-assisted diagnosis, diagnostic accuracy, workflow efficiency, patient safety, workforce planning
- MeSH terms
- Radiologists, Artificial Intelligence, Attitude of Health Personnel, Child, Humans, Surveys and Questionnaires, Radiology
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Artificial intelligence in paediatric radiology: international survey of health care professionals’ opinions. https://app.cochat.ai/papers/10.1007/s00247-021-05195-5
- The paper
- Shelmerdine, S. C., Rosendahl, K., & Arthurs, O. J. (2022). Artificial intelligence in paediatric radiology: international survey of health care professionals’ opinions. Pediatric Radiology. https://doi.org/10.1007/s00247-021-05195-5
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.