Load-dependent release limits the processive stepping of the tetrameric Eg5 motor
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Tetrameric motor proteins of the Kinesin-5 family are essential for eukaryotic cell division. The microscopic mechanism by which Eg5, the vertebrate Kinesin-5, drives bipolar mitotic spindle formation remains unknown. Here we show in optical trapping experiments that full-length Eg5 moves processively and stepwise along microtubule bundles. Interestingly, the force produced by individual Eg5 motors typically reached only approximately 2 pN, one-third of the stall force of Kinesin-1. Eg5 typically detached from microtubules before stalling. This behavior may reflect a regulatory mechanism important for the role of Eg5 in the mitotic spindle.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Direct observation of kinesin stepping by optical trapping interferometry
Svoboda, K., Schmidt, C. F., Schnapp, B. J., & Block, S. M. (1993) · Nature · doi:10.1038/365721a0 · Cited by 1,910
Self-citationForce and velocity measured for single kinesin molecules
Svoboda, K., & Block, S. M. (1994) · Cell · doi:10.1016/0092-8674(94)90060-4 · Cited by 909 · cited 3×
“The linkage stiVness found for Eg5 is comparable to what has been reported for similar experiments with Kinesin-1 (Svoboda and Block 1994; Svoboda et al. 1993).”
BackgroundResultThe bipolar mitotic kinesin Eg5 moves on both microtubules that it crosslinks
Kapitein, L. C., Peterman, E. J. G., Kwok, B. H., Kim, J. H., Kapoor, T. M., & Schmidt, C. F. (2005) · Nature · doi:10.1038/nature03503 · Cited by 678 · cited 1×
“We have recently shown that Eg5 drives relative sliding of two microtubules, suggesting that each dimeric end walks on one microtubule (Kapitein et al. 2005).”
BackgroundSelf-citationKashlna, A. S., Baskin, R. J., Cole, D. G., Wedaman, K. P., Saxton, W. M., & Scholey, J. M. (1996) · Nature · doi:10.1038/379270a0 · Cited by 352 · cited 1×
“Kinesin-5 motors play a crucial role in cell division (Kashina et al. 1996; Sawin et al. 1992).”
BackgroundValentine, M. T., Fordyce, P. M., Krzysiak, T. C., Gilbert, S. P., & Block, S. M. (2006) · Nature Cell Biology · doi:10.1038/ncb1394 · Cited by 260
Allosteric inhibition of kinesin-5 modulates its processive directional motility
Kwok, B. H., Kapitein, L. C., Kim, J. H., Peterman, E. J. G., Schmidt, C. F., & Kapoor, T. M. (2006) · Nature Chemical Biology · doi:10.1038/nchembio812 · Cited by 108
Self-citation
Cited by
Subramanian, R., Wilson-Kubalek, E. M., Arthur, C. P., Bick, M. J., Campbell, E. A., Darst, S. A., Milligan, R. A., & Kapoor, T. M. (2010) · Cell · doi:10.1016/j.cell.2010.07.012 · Cited by 301
Microtubule organization by the antagonistic mitotic motors kinesin-5 and kinesin-14
Hentrich, C., & Surrey, T. (2010) · The Journal of Cell Biology · doi:10.1083/jcb.200910125 · Cited by 167
Microtubule cross-linking triggers the directional motility of kinesin-5
Kapitein, L. C., Kwok, B. H., Weinger, J. S., Schmidt, C. F., Kapoor, T. M., & Peterman, E. J. G. (2008) · The Journal of Cell Biology · doi:10.1083/jcb.200801145 · Cited by 143
“However, in a similar assay, fulllength Eg5 moved processively over longer distances, but in an irregular manner, indicating diffusive periods ( Korneev et al., 2007 ).”
Self-citation
Metadata
- Authors
- Korneev, M. J., Lakämper, S., & Schmidt, C. F.
- Venue
- European Biophysics Journal
- Published
- 2007-02-28
- Volume
- 36
- Issue
- 6
- Pages
- 675-681
- ISSN
- 0175-7571 (ISSN-L)
- 1432-1017
- OpenAlex
- W2142022393
- Cited by
- 42
- References
- 6
- FWCI
- 2.11
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Load-dependent release limits the processive stepping of the tetrameric Eg5 motor. https://app.cochat.ai/papers/10.1007/s00249-007-0134-6
- The paper
- Korneev, M. J., Lakämper, S., & Schmidt, C. F. (2007). Load-dependent release limits the processive stepping of the tetrameric Eg5 motor. European Biophysics Journal. https://doi.org/10.1007/s00249-007-0134-6
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.