The DOI matches its Crossref record.
Scatter modelling and compensation in emission tomography
Open accessAbstract
In nuclear medicine, clinical assessment and diagnosis are generally based on qualitative assessment of the distribution pattern of radiotracers used. In addition, emission tomography (SPECT and PET) imaging methods offer the possibility of quantitative assessment of tracer concentration in vivo to quantify relevant parameters in clinical and research settings, provided accurate correction for the physical degrading factors (e.g. attenuation, scatter, partial volume effects) hampering their quantitative accuracy are applied. This review addresses the problem of Compton scattering as the dominant photon interaction phenomenon in emission tomography and discusses its impact on both the quality of reconstructed clinical images and the accuracy of quantitative analysis. After a general introduction, there is a section in which scatter modelling in uniform and non-uniform media is described in detail. This is followed by an overview of scatter compensation techniques and evaluation strategies used for the assessment of these correction methods. In the process, emphasis is placed on the clinical impact of image degradation due to Compton scattering. This, in turn, stresses the need for implementation of more accurate algorithms in software supplied by scanner manufacturers, although the choice of a general-purpose algorithm or algorithms may be difficult.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
PET versus SPECT: strengths, limitations and challenges
Rahmim, A., & Zaidi, H. (2008) · Nuclear Medicine Communications · doi:10.1097/mnm.0b013e3282f3a515 · Cited by 834
Self-citationEANM/ESC procedural guidelines for myocardial perfusion imaging in nuclear cardiology
Hesse, B., Tägil, K., Cuocolo, A., Anagnostopoulos, C., Bardiés, M., Bax, J., Bengel, F., Busemann Sokole, E., Davies, G., Dondi, M., et al. (2005) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-005-1779-y · Cited by 527
Flotats, A., Carrió, I., Agostini, D., Le Guludec, D., Marcassa, C., Schaffers, M., Somsen, G. A., Unlu, M., & Verberne, H. J. (2010) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-010-1491-4 · Cited by 339
Recent Advances in SPECT Imaging
Madsen, M. T. (2007) · Journal of Nuclear Medicine · doi:10.2967/jnumed.106.032680 · Cited by 338
The promise of artificial intelligence and deep learning in PET and SPECT imaging
Arabi, H., AkhavanAllaf, A., Sanaat, A., Shiri, I., & Zaidi, H. (2021) · Physica Medica · doi:10.1016/j.ejmp.2021.03.008 · Cited by 268
Self-citation
Metadata
- Authors
- Zaidi, H., & Koral, K. F.
- Venue
- European Journal of Nuclear Medicine and Molecular Imaging
- Published
- 2004-05-01
- Volume
- 31
- Issue
- 5
- Pages
- 761-782
- ISSN
- 1619-7070 (ISSN-L)
- 1619-7089
- OpenAlex
- W2112136242
- Cited by
- 214
- References
- 0
- FWCI
- 12.30
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Scatter modelling and compensation in emission tomography. https://app.cochat.ai/papers/10.1007/s00259-004-1495-z
- The paper
- Zaidi, H., & Koral, K. F. (2004). Scatter modelling and compensation in emission tomography. European Journal of Nuclear Medicine and Molecular Imaging. https://doi.org/10.1007/s00259-004-1495-z
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.