The DOI matches its Crossref record.
A fast cardiac gamma camera with dynamic SPECT capabilities: design, system validation and future potential
Open accessAbstract
PURPOSE: The goal of this study is to present the Discovery NM 530c (DNM), a cardiac SPECT camera, interfacing multi-pinhole collimators with solid-state modules, aiming at slashing acquisition time without jeopardizing quality. DNM resembles PET since it enables 3-D SPECT without detector motion. We further envision how these novel capabilities may help with current and future challenges of cardiac imaging. METHODS: DNM sensitivity, spatial resolution (SR) and energy resolution (ER), count rate response, cardiac uniformity and cardiac defect contrast were measured and compared to a dedicated cardiac, dual-head standard SPECT (S-SPECT) camera. RESULTS: DNM sensitivity was more than threefold higher while SR was notably better. Significantly, SR was the same for (99m)Tc and (201)Tl. ER was improved on DNM and allowed good separation of (99m)Tc and (123)I spectral peaks. Count rate remained linear on DNM up to 612 kcps, while S-SPECT showed severe dead time limitations. Phantom studies revealed comparable uniformity and defect contrast, notwithstanding significantly shorter acquisition time for the DNM. First patient images, including dynamic SPECT, are also presented. CONCLUSION: DNM is raising the bar for expedition and upgrade of practice. It features high sensitivity as well as improved SR, temporal resolution and ER. It enables reduction of acquisition time and fast protocols. Importantly, it is potentially capable of dynamic 3-D acquisition. The new technology is potentially upgradeable and may become a milestone in the evolution of nuclear cardiology as it assumes its key role in molecular imaging of the heart.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Targeting Cardiovascular Implant Infection: Multimodality and Molecular Imaging
Sohns, J. M., Bavendiek, U., Ross, T. L., & Bengel, F. M. (2017) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.117.005376 · Cited by 24
Deep-Learning-Based Few-Angle Cardiac SPECT Reconstruction Using Transformer
Xie, H., Thorn, S., Liu, Y.-H., Lee, S., Liu, Z., Wang, G., Sinusas, A. J., & Liu, C. (2023) · IEEE Transactions on Radiation and Plasma Medical Sciences · doi:10.1109/trpms.2022.3187595 · Cited by 16
Metadata
- Authors
- Bocher, M., Blevis, I. M., Tsukerman, L., Shrem, Y., Kovalski, G., & Volokh, L.
- Venue
- European Journal of Nuclear Medicine and Molecular Imaging
- Published
- 2010-06-29
- Volume
- 37
- Issue
- 10
- Pages
- 1887-1902
- ISSN
- 1619-7070 (ISSN-L)
- 1619-7089
- OpenAlex
- W2089172939
- Cited by
- 303
- References
- 0
- FWCI
- 12.05
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.