Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 167

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Automatic generation of absolute myocardial blood flow images using [15O]H2O and a clinical PET/CT scanner

Open access
Harms, Hendrik J., Knaapen, Paul, de Haan, Stefan, Halbmeijer, Rick, Lammertsma, Adriaan A., Lubberink, Mark · 2011 · European Journal of Nuclear Medicine and Molecular Imaging

Abstract

PURPOSE: Parametric imaging of absolute myocardial blood flow (MBF) using [(15)O]H(2)O enables determination of MBF with high spatial resolution. The aim of this study was to develop a method for generating reproducible, high-quality and quantitative parametric MBF images with minimal user intervention. METHODS: Nineteen patients referred for evaluation of MBF underwent rest and adenosine stress [(15)O]H(2)O positron emission tomography (PET) scans. Ascending aorta and right ventricular (RV) cavity volumes of interest (VOIs) were used as input functions. Implementation of a basis function method (BFM) of the single-tissue model with an additional correction for RV spillover was used to generate parametric images. The average segmental MBF derived from parametric images was compared with MBF obtained using nonlinear least-squares regression (NLR) of VOI data. Four segmentation algorithms were evaluated for automatic extraction of input functions. Segmental MBF obtained using these input functions was compared with MBF obtained using manually defined input functions. RESULTS: The average parametric MBF showed a high agreement with NLR-derived MBF [intraclass correlation coefficient (ICC) = 0.984]. For each segmentation algorithm there was at least one implementation that yielded high agreement (ICC > 0.9) with manually obtained input functions, although MBF calculated using each algorithm was at least 10% higher. Cluster analysis with six clusters yielded the highest agreement (ICC = 0.977), together with good segmentation reproducibility (coefficient of variation of MBF <5%). CONCLUSION: Parametric MBF images of diagnostic quality can be generated automatically using cluster analysis and a implementation of a BFM of the single-tissue model with additional RV spillover correction.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s00259-011-1730-3

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 167

Metadata

Authors
Harms, H. J., Knaapen, P., de Haan, S., Halbmeijer, R., Lammertsma, A. A., & Lubberink, M.
Venue
European Journal of Nuclear Medicine and Molecular Imaging
Published
2011-01-27
Volume
38
Issue
5
Pages
930-939
ISSN
  • 1619-7070 (ISSN-L)
  • 1619-7089
OpenAlex
W2169793356
Cited by
167
References
3
FWCI
5.98
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Automatic generation of absolute myocardial blood flow images using [15O]H2O and a clinical PET/CT scanner. https://app.cochat.ai/papers/10.1007/s00259-011-1730-3
The paper
Harms, H. J., Knaapen, P., de Haan, S., Halbmeijer, R., Lammertsma, A. A., & Lubberink, M. (2011). Automatic generation of absolute myocardial blood flow images using [15O]H2O and a clinical PET/CT scanner. European Journal of Nuclear Medicine and Molecular Imaging. https://doi.org/10.1007/s00259-011-1730-3

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.