CoChat

Impact of [18F]FDG PET imaging parameters on automatic tumour delineation: need for improved tumour delineation methodology

Open access
Cheebsumon, Patsuree, Yaqub, Maqsood, van Velden, Floris H. P., Hoekstra, Otto S., Lammertsma, Adriaan A., Boellaard, Ronald · 2011 · European Journal of Nuclear Medicine and Molecular Imaging
Cited by 108

The DOI matches its Crossref record.

Abstract

PURPOSE: Delineation of tumour boundaries is important for quantification of [(18)F]fluoro-2-deoxy-D-glucose (FDG) positron emission tomography (PET) studies and for definition of biological target volumes in radiotherapy. Several (semi-)automatic tumour delineation methods have been proposed, but these methods differ substantially in estimating tumour volume and their performance may be affected by imaging parameters. The main purpose of this study was to explore the performance dependence of various (semi-)automatic tumour delineation methods on different imaging parameters, i.e. reconstruction parameters, noise levels and tumour characteristics, and thereby the need for standardization or inter-institute calibration. METHODS: Six different types of delineation methods were evaluated by assessing accuracy and precision in estimating tumour volume from simulations and phantom experiments. The evaluated conditions were various tumour sizes, iterative reconstruction algorithm settings and image filtering, tumour to background ratios (TBR), noise levels and region growing initializations. RESULTS: The accuracy of all automatic delineation methods was influenced when imaging parameters were varied. The performance of all tumour delineation methods depends on variation of TBR, image resolution and image noise level, and to a lesser extent on number of iterations during image reconstruction or the initialization method of the region generation. For sphere sizes larger than 20 mm diameter a contrast-oriented method provided the most accurate results, on average, over all simulated conditions. For threshold-based methods the accuracy of tumour delineation improved after image denoising/filtering. CONCLUSION: The accuracy and precision of all studied tumour delineation methods was affected by physiological and imaging parameters. The latter illustrates the need for optimizing imaging parameters and/or for careful calibration and optimization of delineation methods.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s00259-011-1899-5

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 108

Metadata

Authors
Cheebsumon, P., Yaqub, M., van Velden, F. H. P., Hoekstra, O. S., Lammertsma, A. A., & Boellaard, R.
Venue
European Journal of Nuclear Medicine and Molecular Imaging
Published
2011-08-20
Volume
38
Issue
12
Pages
2136-2144
ISSN
  • 1619-7070 (ISSN-L)
  • 1619-7089
OpenAlex
W2083672407
Cited by
108
References
0
FWCI
8.73
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Impact of [18F]FDG PET imaging parameters on automatic tumour delineation: need for improved tumour delineation methodology. https://app.cochat.ai/papers/10.1007/s00259-011-1899-5
The paper
Cheebsumon, P., Yaqub, M., van Velden, F. H. P., Hoekstra, O. S., Lammertsma, A. A., & Boellaard, R. (2011). Impact of [18F]FDG PET imaging parameters on automatic tumour delineation: need for improved tumour delineation methodology. European Journal of Nuclear Medicine and Molecular Imaging. https://doi.org/10.1007/s00259-011-1899-5

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.