CoChat

18F-radiolabeled analogs of exendin-4 for PET imaging of GLP-1 in insulinoma

Open access
Kiesewetter, Dale O., Gao, Haokao, Ma, Ying, Niu, Gang, Quan, Qimeng, Guo, Ning, Chen, Xiaoyuan · 2012 · European Journal of Nuclear Medicine and Molecular Imaging
Cited by 107

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

PurposeGlucagon-like peptide type 1 (GLP-1) is an incretin peptide that augments glucose-stimulated insulin release following oral consumption of nutrients. Its message is transmitted via a G protein-coupled receptor called GLP-1R, which is colocalized with pancreatic β-cells. The GLP-1 system is responsible for enhancing insulin release, inhibiting glucagon production, inhibiting hepatic gluconeogenesis, inhibiting gastric mobility, and suppression of appetite. The abundance of GLP-1R in pancreatic β-cells in insulinoma, a cancer of the pancreas, and the activity of GLP-1 in the cardiovascular system have made GLP-1R a target for molecular imaging.MethodsWe prepared 18F radioligands for GLP-1R by the reaction of [18F]FBEM, a maleimide prosthetic group, with [Cys0] and [Cys40] analogs of exendin-4. The binding affinity, cellular uptake and internalization, in vitro stability, and uptake and specificity of uptake of the resulting compounds were determined in an INS-1 xenograft model in nude mice.ResultsThe [18F]FBEM-[Cysx]-exendin-4 analogs were obtained in good yield (34.3 ± 3.4%, n = 11), based on the starting compound [18F]FBEM), and had a specific activity of 45.51 ± 16.28 GBq/μmol (1.23 ± 0.44 Ci/μmol, n = 7) at the end of synthesis. The C-terminal isomer, [18F]FBEM-[Cys40]-exendin-4, had higher affinity for INS-1 tumor cells (IC50 1.11 ± 0.057 nM) and higher tumor uptake (25.25 ± 3.39 %ID/g at 1 h) than the N-terminal isomer, [18F]FBEM-[Cys0]-exendin-4 (IC50 2.99 ± 0.06 nM, uptake 7.20 ± 1.26 %ID/g at 1 h). Uptake of both isomers into INS-1 tumor, pancreas, stomach, and lung could be blocked by preinjection of nonradiolabeled [Cysx]-exendin-4 (p < 0.05).Conclusion[18F]FBEM-[Cys40]-exendin-4 and [18F]FBEM-[Cys0]-exendin-4 have high affinity for GLP-1R and display similar in vitro cell internalization. The higher uptake into INS-1 xenograft tumors exhibited by [18F]FBEM-[Cys40]-exendin-4 suggests that this compound would be the better tracer for imaging GLP-1R.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s00259-011-1980-0

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 107

Metadata

Authors
Kiesewetter, D. O., Gao, H., Ma, Y., Niu, G., Quan, Q., Guo, N., & Chen, X.
Venue
European Journal of Nuclear Medicine and Molecular Imaging
Published
2011-12-15
Volume
39
Issue
3
Pages
463-473
ISSN
  • 1619-7070 (ISSN-L)
  • 1619-7089
OpenAlex
W2045756267
Cited by
107
References
2
FWCI
6.43
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: 18F-radiolabeled analogs of exendin-4 for PET imaging of GLP-1 in insulinoma. https://app.cochat.ai/papers/10.1007/s00259-011-1980-0
The paper
Kiesewetter, D. O., Gao, H., Ma, Y., Niu, G., Quan, Q., Guo, N., & Chen, X. (2012). 18F-radiolabeled analogs of exendin-4 for PET imaging of GLP-1 in insulinoma. European Journal of Nuclear Medicine and Molecular Imaging. https://doi.org/10.1007/s00259-011-1980-0

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.